46
Temposonics
®
TH CANbus ATEX / IECEx / CEC / NEC / KCs / EAC Ex certified / Japanese approval
Operation Manual
8. Technical data Temposonics
®
TH
Output
Interface
CAN-Fieldbus System according to ISO 11898
Data protocol
Corresponds to encoder profile DS 406 V3.1 (CiA Standard DS 301 V3.0)
Baud rate, kBit/s
Cable length, m
1000 800 500 250 125 50 20
< 25 < 50 < 100 < 250 < 500 < 1000 < 2500
The sensor will be supplied with ordered baud rate, which is changeable by customer
Measured value
Position / option: Multi-position measurement (2…4 positions)
Measurement parameters
Resolution
2 µm, 5 µm; velocity step size: See following table
For stroke lengths
having a
cycle time of
Velocity step size
at 5 µm position
resolution
at 2 µm position
resolution
Up to 2400 mm
1.0 ms
results in the following
velocity step size
0.5 mm/s
0.2 mm/s
Up to 4800 mm
2.0 ms
0.25 mm/s
0.1 mm/s
Up to 7620 mm
4.0 ms
0.125 mm/s
0.05 mm/s
Cycle time
1.0 ms up to 2400 mm stroke length
2.0 ms up to 4800 mm stroke length
4.0 ms up to 7620 mm stroke length
Linearity deviation
7
< ±0.01 % F.S. (minimum ±40 μm)
Repeatability
< ±0.001 % F.S. (minimum ±2.5 µm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm/K typical
Operating conditions
Operating temperature
−40…+75 °C (−40…+167 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
Version D, G, and E: IP66 / IP67 (if properly connected by means that support IP66 / IP67
(pipe, gland, etc.))
Version N: IP66, IP67, IP68, IP69K, NEMA 4X, depending on cable gland
Shock test
100 g (single shock), IEC standard 60068-2-27
Vibration test
15 g / 10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The sensor meets the requirements of the EU directives and is marked with
Operating pressure
350 bar static (5076 psi static)
Magnet movement velocity
8
Any
Design / Material
Sensor electronics housing
Stainless steel 1.4305 (AISI 303); option: Stainless steel 1.4404 (AISI 316L)
Flange
See “Table 1: TH rod sensor threaded flange type references” on page 12
Sensor rod
Stainless steel 1.4306 (AISI 304L); option: Stainless steel 1.4404 (AISI 316L)
Stroke length
25…7620 mm (1…300 in.)
7/
With position magnet # 201 542-2
8/
If there is contact between the moving magnet (including the magnet holder) and the sensor rod, make sure that the maximum speed of the moving magnet is ≤ 1 m/s
(Safety requirement due to ESD [Electro Static Discharge])
See next page for “Mechanical mounting”