MTI DOC 91795-A1
4
CONNECTING TO THE NETWORK
The 91795 Embedded Controller supports a 100 Mbps network connection.
1.
Connect a Cat5e (or better) unshielded twisted pair (UTP) cable and connector to the RJ-
45 connector on the 91795.
2.
Connect the other end of the UTP cable to an available port on a 10/100 (minimum)
compatible network switch.
CONNECTING POWER
The 91795 Embedded Controller requires a connection to a 12V DC power supply which is
capable of supplying 2 A of current. The 91795 should be connected to the 12V DC power
supply using a minimum of 14 gauge copper conductors. MTI recommends that the 12V DC
power supply be connected to an uninterruptible power supply (UPS).
To connect power:
1.
Connect two power conductors to pin 1 and 2 of the power connector.
2.
Connect the other end of the two power conductors to the appropriate power source.