background image

M10000 Diesel 

Passenger Set

Compatibility

This engine will operate on any traditional 
O-72 Gauge track system, including 
M.T.H.’s RealTrax® or ScaleTrax™ or 
traditional tubular track. It is also 
compatible with most standard AC 
transformers.  (See pag e 22 for a complete 
list of  compatible transformers and 
wiring instructions.)

PLEASE READ BEFORE USE AND SAVE

OPERATOR’S MANUAL (3V PS-2)

Passenger Station Announcement

Содержание M10000 Diesel Passenger Set

Страница 1: ...system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 22 for a complete list of compatible transformers and wiri...

Страница 2: ...681 6 491 263 6 604 641 6 619 594 6 624 537 6 655 640 2008 M T H Electric Trains Columbia MD 21046 CAUTION ELECTRICALLY OPERA TED PRODUCT WARNING When using electrical products basic safety precautio...

Страница 3: ...o not over oil Use only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down...

Страница 4: ...add smoke fluid or have already added fluid but choose to run smoke free turn off the smoke unit by turning the smoke unit control fully counter clockwise Failure either to add fluid to the smoke uni...

Страница 5: ...e and the truck 5 Release the vestibule and listen for the tongue to lock into place 6 Repeat to connect the second car In order to disconnect the cars Simply depress the vestibule and pull the cars a...

Страница 6: ...will continue to ring from the time you turn it on until you press and release the button again to turn it off Horn Whistle To sound the whistle firmly press the Horn Whistle button The whistle will s...

Страница 7: ...l sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier M10000 Diesel Passenger Set Proto Sound 2...

Страница 8: ...quickly but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Pre...

Страница 9: ...Sound engine FYS PSA are triggered differently and that engine s motor disable feature will not be active when you run FYS PSA in Proto Sound 2 0 FYS PSA can be triggered from Neutral It will operate...

Страница 10: ...neutral then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1...

Страница 11: ...whistle blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes p...

Страница 12: ...he gear box remove the cab from the chassis by unscrewing the body mount screws as seen in photo below and lifting the cab from the chassis 2 Once the cab is removed remove the trucks by unscrewing th...

Страница 13: ...cohol applied with a cotton swab To clean the track use RailKing Track Cleaning Fluid found in Maintenance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe...

Страница 14: ...any remains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the whe...

Страница 15: ...dy is removed locate the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M...

Страница 16: ...tery charge has run down and can be recharged There are a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the battery can fully recharge i...

Страница 17: ...shown below We recommend M T H ProtoSmoke fluid Do not overfill the unit or the fluid may leak out and coat the interior engine components To adjust the amount of smoke produced turn the smoke unit v...

Страница 18: ...and unabsorbent around the heating element After removing the locomotive body from its chassis remove the smoke unit inspection cover shown below After removing the inspection cover screws lift the i...

Страница 19: ...ss the bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay...

Страница 20: ...ervals The engine is locked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Pro...

Страница 21: ...can be as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequenc...

Страница 22: ...att Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Term...

Страница 23: ...but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including sound lights and smoke Proto Dispatch Operatio...

Страница 24: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Отзывы: