MTHTrains 20-2713-1 Скачать руководство пользователя страница 1

Premier  F40PH Diesel Engine

OPERATOR’S MANUAL

(3V PS-2)

(Proto-Scale 3-2)

Compatibility

This engine will operate on any 
traditional O-31 Gauge track system, 
including M.T.H.’s RealTrax® or 
ScaleTrax™ or traditional tubular 
track. It is also compatible with most 
standard AC transformers.  (See page 
24 for a complete list of  compatible 
transformers and wiring instructions.)

Freight Yard Sound

PLEASE READ BEFORE USE AND SAVE

Содержание 20-2713-1

Страница 1: ...te on any traditional O 31 Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 24 for a complete l...

Страница 2: ...of age M T H recommends adult supervision with children ages 10 16 As with all electric products precautions should be observed during handling and use to reduce the risk of electric shock WARNING Wh...

Страница 3: ...ints marked L in Fig 1 Do not over oil Use only a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeab...

Страница 4: ...f you choose not to add smoke fluid or have already added fluid but choose to run smoke free turn off the smoke unit by turning the smoke unit control to the OFF position fully Counter Clockwise posit...

Страница 5: ...ail Track To configure the locomotive for 2 Rail track operation please do the following 1 Remove the center rail pickup roller assemblies 2 Change the power input from 3 Rail to 2 Rail as seen in fig...

Страница 6: ...and polarity shown in Figure 5 the DCS Polarity switch should be towards the front of the locomotive Premier F40PH Diesel Engine with PS 2 6 Ensuring Proper Power to Track Polarity Changing Track Pola...

Страница 7: ...will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release...

Страница 8: ...of all sounds made by this engine turn the master volume control knob located next to the fuel tank clockwise to increase the volume and counter clockwise to decrease the volume Premier F40PH Diesel...

Страница 9: ...but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the D...

Страница 10: ...level once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatical...

Страница 11: ...l then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn wh...

Страница 12: ...blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any...

Страница 13: ...reased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first Follow the greasing instructions below for each gear box 1 Remove the Ro...

Страница 14: ...t the neoprene traction tires Wheels and tires can be cleaned using denatured not rubbing alcohol applied with a cotton swab To clean the track use RailKing Track Cleaning Fluid or denatured not rubbi...

Страница 15: ...the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you will need to remove and reins...

Страница 16: ...body is removed locate the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the...

Страница 17: ...t and a special port under the engine to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to rep...

Страница 18: ...adjust the amount of smoke produced turn the smoke unit volume control clockwise to increase the amount of smoke or counter clockwise to reduce the amount se Figure 3 If you choose not to add smoke f...

Страница 19: ...ody from its chassis See Figure 5 remove the smoke unit inspection cover see Figure 8 After removing the inspection cover screws lift the inspection plate away and inspect the wick If it is darkly dis...

Страница 20: ...e bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled When I press...

Страница 21: ...d into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set...

Страница 22: ...as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS...

Страница 23: ...le button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions includin...

Страница 24: ...ard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Le...

Страница 25: ...Supplies Proto Sound 2 0 is designed to work with most standard DC power supplies and AC transformers The following charts lists the recommended DC and AC transformers Note that many of the AC operat...

Страница 26: ...less of whether you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instructions carefully befor...

Отзывы: