6. START-UP 

 

Safety Precautions 

 

Before start-up, observe the following warnings and instructions: 

 

 

 

WARNING

 

 

Internal components of the filter are at line potential when the filter is 

connected to the drive. This voltage is extremely dangerous and may cause 

death or severe injury if you come in contact with it. 

Use extreme caution to avoid contact with line voltage when checking for 

power.

 INJURY OR DEATH MAY RESULT IF SAFETY PRECAUTIONS 

ARE NOT OBSERVED.

 

Damage to equipment or serious injury may occur if the inverter start-up 

procedures are not observed. 

 

Caution

 

Damage to the filter may occur if the appropriate output carrier frequency 

is not observed.  

 

Sequence of Operation 

 

1.  Read and follow safety precautions. 

2.  After installation, ensure that: 

  All filter ground terminals are connected to ground. 

  Power wiring to the utility, drive, filter, and motor is in accordance with the power 

wiring connection diagrams shown in installation instructions section. 

3.  Check that moisture has not condensed on the filter components. If moisture is present, 

do not proceed with start-up until the moisture has been removed. 

4.  Disconnect filter output terminals from the motor. 

5.  Set the drive switching frequency to the appropriate setting. 

  2kHz – 4kHz (3A – 750A Filters) 

6.  Connect filter temperature safety overload switch into the control circuit so that the drive 

will shut down in an overload situation. 

7.  Confirm that drive voltage is present at the input terminals (U1, V1, W1) of the filter. 

8.  Confirm that drive voltage is present at the output terminals (U2, V2, W2) of the filter. 

9.  Connect the filter output to the motor. 

10. Refer to the drive user manual for the drive start-up procedure. Observe all safety 

instructions in the drive user manual. 

 

 

Содержание dV E Series

Страница 1: ...WARNING High Voltage Only a qualified electrician can carry out the electrical installation of this filter Quick Reference Performance Data Pages 9 12 Selection Guide Pages 13 18 Installation Guide P...

Страница 2: ...This page intentionally left blank...

Страница 3: ...E SPECIFICATIONS 9 FILTER EFFICIENCY WATT LOSS 10 PERFORMANCE CHART 11 ALTITUDE DERATING 12 MOTOR FREQUENCY DERATING 12 4 HOW TO SELECT 13 SELECTION GUIDE 13 UNDERSTANDING THE DV E SERIES PART NUMBER...

Страница 4: ...12 Figure 5 1 Basic Schematic Diagram 21 Figure 5 2 Kit Diagram 22 Figure 5 3 Open Panel and Enclosed Diagram 23 List of Tables Table 3 1 Performance Specifications 9 Table 3 2 Filter Efficiency Watt...

Страница 5: ...volved Failure to use proper precautions may lead to serious injury or death WARNING General Warning warns of situations that can result in serious injury or death if proper precautions are not used C...

Страница 6: ...al Code NEC or governing authority Even if the upstream disconnect protection device is open the drive down stream of the filter may feedback high voltage to the filter The drive safety instructions m...

Страница 7: ...tatement Upon Receipt of this Filter The dV E Series motor protection filter has been subjected to demanding factory tests before shipment Carefully inspect the shipping container for damage that may...

Страница 8: ...e protection against contact with the enclosed equipment Type 2 NEMA IEC IP20 Enclosure Are designed for indoor use and will provide protection against contact with the enclosed equipment and provide...

Страница 9: ...40C to 60C Modular Filter 40C to 50C Enclosed Filter 40C to 90C Storage Insulation System Class N 200 C Insertion Loss Voltage 1 7 at 60 Hz Efficiency 99 Current range 3A 750A Available form factors K...

Страница 10: ...Power Dissipation Watts 3 99 0 51 4 99 0 54 7 99 0 64 9 99 0 70 12 99 0 86 17 99 0 111 22 99 0 97 27 99 0 95 35 99 0 91 45 99 0 76 55 99 0 102 65 99 0 152 80 99 0 122 110 99 0 92 130 99 0 113 160 99 0...

Страница 11: ...dV E Series Technical Reference Manual 208V 600V 11 Form DVT TRM E December 2021 Rev 001 Performance Chart Figure 3 1 Typical Performance Chart...

Страница 12: ...Technical Reference Manual 208V 600V Form DVT TRM E December 2021 Rev 001 12 Altitude Derating Figure 3 2 Altitude Derating Curve Motor Frequency Derating Figure 3 3 Current Derating for Drive Output...

Страница 13: ...d 3R mechanical configurations Please verify information below for proper selection Lead Length This product is suitable for applications with motor leads up to 1 000 ft Contact MTE Application Engine...

Страница 14: ...December 2021 Rev 001 14 Understanding the dV E Series Part Number DVT X _ _ _ _ E dV E Series Filter Type K Kit P Open Panel G General Purpose NEMA 1 2 W Weather NEMA 3R Current Rating i e 0003 is 3...

Страница 15: ...0 75 10 12 5 15 25 30 35 DVTK0035E 4 4 0 x 4 2 x 4 0 5 0 x 8 1 x 0 75 12 5 15 18 5 22 30 40 45 DVTK0045E 6 4 4 x 4 2 x 4 0 5 0 x 8 1 x 0 75 15 20 40 50 55 DVTK0055E 8 5 0 x 5 9 x 4 3 5 0 x 8 1 x 0 75...

Страница 16: ...9 x 5 5 x 8 0 10 12 5 15 25 30 35 DVTP0035E 9 12 0 x 8 0 x 8 1 12 5 15 18 5 22 30 40 45 DVTP0045E 11 12 0 x 8 0 x 8 1 15 20 40 50 55 DVTP0055E 12 12 0 x 8 0 x 9 0 20 25 30 50 60 65 DVTP0065E 14 12 0...

Страница 17: ...13 2 x 13 0 x 13 1 10 12 5 15 25 30 35 DVTG0035E 21 13 2 x 13 0 x 13 1 12 5 15 18 5 22 30 40 45 DVTG0045E 23 13 2 x 13 0 x 13 1 15 20 40 50 55 DVTG0055E 25 13 2 x 13 0 x 13 1 20 25 30 50 60 65 DVTG006...

Страница 18: ...5 x 11 0 x 12 0 10 12 5 15 25 30 35 DVTW0035E 31 15 5 x 11 0 x 12 0 12 5 15 18 5 22 30 40 45 DVTW0045E 33 15 5 x 11 0 x 12 0 15 20 40 50 55 DVTW0055E 66 24 0 x 12 5 x 23 0 20 25 30 50 60 65 DVTW0065E...

Страница 19: ...requirements of the enclosure include the power dissipation of the filter along with all the other components located in the panel A general guideline is to allow a side clearance of four 4 inches an...

Страница 20: ...d Enclosed Diagram p23 Wire gauge range and terminal torque requirements for the dV E Series are shown in Table 5 1 Torque Ratings p24 Refer to the drive user manual for instructions on interconnectin...

Страница 21: ...dV E Series Technical Reference Manual 208V 600V 21 Form DVT TRM E December 2021 Rev 001 Basic Schematic Diagram Figure 5 1 Basic Schematic Diagram...

Страница 22: ...dV E Series Technical Reference Manual 208V 600V Form DVT TRM E December 2021 Rev 001 22 Interconnection Diagram Kit Figure 5 2 Kit Diagram...

Страница 23: ...dV E Series Technical Reference Manual 208V 600V 23 Form DVT TRM E December 2021 Rev 001 Interconnection Diagram Open Panel and Enclosed Figure 5 3 Open Panel and Enclosed Diagram...

Страница 24: ...2x or 3 0 N A 14 16 250 1 2x or 250kcmil N A 14 16 305 2 0 2x N A 14 16 365 3 0 2x N A 14 16 415 4 0 2x N A 14 16 515 300kcmil 2x N A 14 16 600 350kcmil 2x N A 14 16 750 N A 14 16 NOTE Kit versions of...

Страница 25: ...ter installation ensure that All filter ground terminals are connected to ground Power wiring to the utility drive filter and motor is in accordance with the power wiring connection diagrams shown in...

Страница 26: ...ly and in accordance with OSHA Regulations High voltage is used in the operation of this filter Use Extreme caution to avoid contact with high voltage when operating installing or repairing this filte...

Страница 27: ...tage and shutdown parameters are valid PROBLEM dV E Series filter runs Hot Possible cause Normal operation reactor 150 C and resistors 300 C Solution Caution Parts are very hot and may cause burns Fol...

Отзывы: