2
S.br
Break in thermocouple wire
Thermocouple failure
Verify all connections from
controller to remote TC jack
Replace thermocouple
3
No heat at nozzle
Heater air flow too low
Defective heating element
Defective power control
Increase air flow
Replace heating element.
Contact Beahm Designs
4
.Err code in display
Temperature controller
software failure.
Replace temperature
controller.
5
System will not power on.
IEC power cord not fully
connected.
Verify installation.
Table 6. Diagnostics and Troubleshooting
Facility Requirements (160-A, 185-A, and 210-A)
1. Voltage: 120-240 VAC 50/60 Hz.
2. Wattage: 500 max.
3. Compressed Air: 100-125 psi, 1.0 SCFM, filtered 50 micron or greater, oil and water
free.