Calibration (See Notes Below)
1. It is recommended that calibration be performed by a certified service, preferably
with the system in the location of use. Calibration procedures are the domain of these
service providers.
2. Calibration refers to the process of verifying that each of
the systems’ instruments
that control a process parameter is
within manufacturers’
specification.
3. Calibration DOES NOT refer to the process of measuring the temperature at the
center of the tooling and
“matching”
the value to the temperature controller set point.
4. The measured value at the tooling (thermal nozzle) may not match the temperature
controller set point and the delta is dependent on nozzle style and dimensions as well as
method of measurement.
a.
Calibrate the temperature controller annually.
b.
Calibrate the pressure gauge annually.
c.
Verify the flow meter annually.
Tuning Temperature Controllers (Eurotherm Model 3216e)
Note: Auto-tuning can be performed at any temperature set point within the system
operating specifications, however, best results are attained at temperatures about
500°F
a.
Depress the scroll button until ATUN appears.
b.
Depress the Up-arrow button until ON appears.
c.
System will resume normal operation automatically after approximately 2
minutes.
Critical Spare Parts (Contact Beahm Designs for pricing)
Item
P/N
Description
1
1348043-001 GRADE A GAUGE
2
1343250-001
3‐way
pneumatic valve
3
1150440-001 Temperature Controller
Table 5.Critical Spare Parts with descriptions
Diagnostics (Troubleshooting)
Issue
Possible Causes
Solution
1
Temperature not stable
Thermal Nozzle
replaced.
Thermocouple loose
Auto‐tune
Re‐install
thermocouple