MSE MS-1210C Скачать руководство пользователя страница 7

 

PROTECTION DESCRPTION: 

Battery  Polarity  Reverse  Protection

:  when  the  battery  polarity  is  reversed,  the 

BATT indicator light will display RED and the BATTERY and  LOAD terminals will 

terminate output.  Battery reverse will  not  damage  the  model  if the  AC  power  is off. 

The AC switch must be turned off at any time when the battery is changed. If AC is 

on and the battery is connected, the PS polarity reverse protection is disabled, and if 

the  polarity  is  reversed  again,  the  fuse  of  the  PS  will  be  burnt,  sometimes  causing  a 

spark. 

Battery  Low  Voltage  protection

:  When  the  AC  is  OFF  or  has  failed,  if  the  battery 

voltage is  lower than 10.7V±0.2V, the  model will turn off the battery and the output 

on  LOAD.  When  AC  returns  or  the  battery  voltage  returns  to  12.6V±0.2V,  then  the 

output on LOAD will recover automatically. 

Load Over Current Protection

: the model will automatically shut down if the load 

is over 12A. when the load is reduced, the PS will auto recover. 

Load Over Voltage Protection

: when the LOAD output is over 18V, the PS will turn 

off. 

Load Short Circuit Protection

: output terminal short circuit will not damage the PS, 

it will be simply stop the output. When the short circuit status is removed, the LOAD 

will recover immediately.   

 

Содержание MS-1210C

Страница 1: ... weight only 4 63 lbs 2 1kg Dimensions 252 54 190 m m W H D Over Voltage protection Over Current protection Quiet Internal Cooling Fan Input Voltage Selectable AC input voltage 115 Vac at 50 60Hz 5 1A F L 230 Vac at 50 60Hz 2 6A F L Super Regulation Works with AC input from 90 to 265Vac Back up Power Supply System Compatible with Solar and Wind Charge Controllers ...

Страница 2: ...ight RED when connection is incorrect 3 4 CHD Full Charged Indicator Light GREEN when battery is full charged 3 5 CHG Charging Indicator Light YELLOW when battery is in charging mode 3 6 AGM Battery Type Indicator Green LED light on when battery type selector is set on AGM position 3 7 WET Battery Type Indicator Yellow LED light on when battery type selector is set on WET position 4 LOAD Output Te...

Страница 3: ...tery is correctly connected select WET for wet battery AGM for AGM battery default setting is AGM You may connect a solar panel or wind turbine to the BATTERY terminal at the same time by connecting a solar panel or wind turbine controller to the battery terminals please make sure it is as the same polarity as battery otherwise it will damage the battery and the control circuit 1 2 3 4 A B C D 4 3...

Страница 4: ...e to the BATTERY terminal at the same time if AC failed when the battery voltage lower than 10 7V the LOAD output will turn off but if the output voltage of the solar panel or wind turbine is higher than the battery voltage the battery will be charged by the solar panel or wind turbine when the battery voltage is back to 12 6V the LOAD output will recover automatically The maximum load of the PS i...

Страница 5: ...to turn on when the inner temperature of unit over 50C and will turned off when the temperature less than 45C NOTICE 1 DON T CONNECT THE PS TO 24V BATTERY The PS was designed for 12V system Connection to the wrong battery will damage the PS 2 THE AC SWITCH MUST BE TURNED OFF AT ANY TIME WHEN THE BATTERY IS CHANGED 3 Select the correct battery type on the panel wrong selection will damage the batte...

Страница 6: ... device to the PS should be 14AWG min Please keeping the connect points clean to avoid spark or electrical leakage 6 When connecting a solar panel or wind turbine controller to the PS please make sure of the correct polarity 7 Product label ...

Страница 7: ...ng a spark Battery Low Voltage protection When the AC is OFF or has failed if the battery voltage is lower than 10 7V 0 2V the model will turn off the battery and the output on LOAD When AC returns or the battery voltage returns to 12 6V 0 2V then the output on LOAD will recover automatically Load Over Current Protection the model will automatically shut down if the load is over 12A when the load ...

Отзывы: