WARNING!

Do NOT use a rechargeable battery that shows signs of damage such as bulging, swelling, leaking fluid, a cracked
housing, or broken contacts.

Do NOT use a rechargeable battery charging system if any component of the system shows damage. Replace the
components if they shows cracks or distortion, or if the cord shows damage or wear.

Do NOT attempt to open the housing of the rechargeable battery module. The rechargeable battery module does not have
replaceable cells.

Do NOT dispose of batteries in a fire. Batteries can explode. Dispose of in accordance with local regulations and
requirements.

Use only the MSA rechargeable battery charging system (P/N 10215631) with the io1 rechargeable battery.

Keep the io1 and rechargeable battery charging system dry. Do NOT disassemble, repair, or alter the io1 or charging
system. Do NOT immerse in water or other liquids.

Only use the io1 in temperatures between 32°F (0°C) and 104°F (40°C).

Do NOT expose the rechargeable battery or charging system to high temperature or heating equipment including, but not
limited to, direct sunlight and water heaters. Overheating may cause an explosion.

Do NOT drop, crush or puncture the rechargeable battery or charging system. Damage from such occurrences can lead to
short-circuit and overheating of the equipment.

Failure to follow these warnings can result in serious personal injury or death.

5.1

Using the V-TEC io1 System

5.1.1 Connecting the V-TEC io1 system to the D-ring

Attach the io1 to the D-ring.

NOTE:

When contact is made, the io1 plays a "connection" tri-tone sound and an LED pulses green.

WARNING!

Ensure the io1 turns green.

Failure to follow this warning can result in serious personal injury or death.

If after several tries the io1 is still red when the attached to the D-ring, use a paperclip to reset the device or contact MSA
Customer Service. See

7 Troubleshooting

for more information on resetting the io1.

NOTE:

When the io1 wakes up, a 15 second countdown to connect begins. An alarm sounds at 15 seconds if no connection is

made.

NOTE:

While the io1 and D-ring are connected, the io1 pulses green in 3 second intervals.

NOTE:

If the io1 and D-ring become disconnected, a 30 second countdown to reconnect begins. An alarm sounds at 30

seconds if no connection is made.

12

V-TEC® io1

5 Operation

US

Содержание V-TEC io1

Страница 1: ...User Instructions V TEC io1 Fall Protection Order No 10215637_r0 Print Spec 10000005389 R CR 800000043205 MSAsafety com...

Страница 2: ...two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation You are cautioned that...

Страница 3: ...Specifications 8 4 Installation 8 4 1 Installing the V TEC io1 8 4 2 Installing the RFID Tag 11 5 Operation 12 5 1 Using the V TEC io1 System 12 5 1 1 Connecting the V TEC io1 system to the D ring 12...

Страница 4: ...those for which it was designed Do NOT use fall protection equipment for towing hoisting or material handling Only MSA or persons or entities with written authorization from the manufacturer may make...

Страница 5: ...n During a connection event a tri tone is played to signal connection No alarms are sounded during the connected period If a disconnection occurs when awake the io1 counts down a timer and goes into a...

Страница 6: ...Figure 1 V TEC io1 Components 1 V TEC io1 System 2 V TEC PFL 3 io1 Component 4 Snaphook 5 RFID Tag 6 Box 7 Carabiner 8 Charging Kit 6 V TEC io1 2 Description US...

Страница 7: ...ifications Capacity 310 lbs 141 kg Anchorage Strength 3 600 lbf 16 kN Dimensions 13 5 x 3 4 x 2 75 Product Weight V TEC io1 Only 2 4 lbs Entire Product Kit 4 8 lbs Standards ANSI Z359 14 2014 CSA Z259...

Страница 8: ...oz Dimensions 5 16 x 2 76 x 0 59 inches 10 USB Cable Interface USB 3 0 3 1 Gen 1 5 Gb s Connector 1 USB Type C Male Connector 2 USB Type A Male io1 Input USB C 5V Battery Capacity 350mAh LiPo nom 3 7V...

Страница 9: ...truck contact your local PIT authorized service center b Ensure the connector is fully connected and that there are no loose wires 4 Clean the area of attachment for the auxiliary power pack This sho...

Страница 10: ...ough to the access area to easily reach the already attached power pack 12 Connect the USB type A end of the USB cord to the open port on the power pack NOTE Look for the charge LED near the USB C por...

Страница 11: ...ng the RFID Tag 1 If needed remove the clasp bar of the V TEC io1 RFID tag by using a 2 Phillips screw driver NOTE The two assembly screws are captured and should not be fully removed for disassembly...

Страница 12: ...g but not limited to direct sunlight and water heaters Overheating may cause an explosion Do NOT drop crush or puncture the rechargeable battery or charging system Damage from such occurrences can lea...

Страница 13: ...isual self test of each LED light io1 is turned on or reset with the reset button While in Use Sequence of ascending tones io1 wakes from sleep mode Ascending single tri beep tone io1 connects with ha...

Страница 14: ...nnection point and there should be no loose portions of wire Labels Inspect labels to ensure they are present and all information is legible The labels should be free from abrasions or peeling See MSA...

Страница 15: ...IS STRICTLY LIMITED TO THE TERMS HEREOF MSA SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Exclusive Remedy It is expressly agreed that the Purchaser s sole...

Страница 16: ...For local MSA contacts please visit us at MSAsafety com...

Отзывы: