1.1

Correct Use

The V-TEC io1 Smart Hook Personal Fall Limiter (PFL) (V-TEC io1) is intended for use as part of a complete personal fall
protection system.

The V-TEC io1 is intended to provide real-time audible and visual feedback to users, relaying their connection status to their
PPE.

The V-TEC io1 is intended for use in applications where connections will be made with overhead-mounted personal fall
limiters. The primary application for the V-TEC io1 is Order Picker-type Powered Industrial Trucks.

WARNING!

Use in other applications including, but not limited to, material handling, recreational or sports related activities, or other
activities not described in these user instructions, are not approved by MSA and could result in serious injury or death.

Failure to follow this warning can result in serious personal injury or death.

1.2

Warnings

WARNING!

Device is not Intrinsically Safe. Do not use this device in flammable or explosive environments.

This device is only to be used by trained users in workplace applications

Users of the V-TEC io1 shall be medically fit and suitably trained. The V-TEC io1 shall not be used by pregnant women,
minors or those under the influence of alcohol or drugs.

The V-TEC io1 is intended to be used as a connecting element between a full body harness and anchor point. A full body
harness is the only acceptable body holding device to be used with a V-TEC io1. If supplied as part of a complete system,
components shall not be substituted.

TheV-TEC io1 is only to be used for its intended purpose and within its limitations. Further clarification can be obtained from
MSA.

For use in accordance with acceptable locations (Table 3). Do not use over an edge or in a situation where a fall would
result in contact with an edge.

For single user only within the weight range 60 - 140 kg (130 - 310 lbs) (including tools). Suitable for use up to 181 kg (400
lbs) (including tools) under OSHA only.

The V-TEC io1 must be protected from sharp edges, abrasive surfaces, fire, acids, caustic solutions, or temperatures
outside the range -40 °C to 54 °C (-40 °F to 130 °F).

The lifeline shall not come into contact with hot surfaces (such as hot pipes); become entangled with moving machinery; or
contact with electrical hazards (such as power lines).

Unsuitable for use on unstable surfaces, fine grain materials, or particulate surfaces such as sand or coal.

Additional lanyard connectors shall not be connected., as this would serve to lengthen the lifeline and increase freefall.

The V-TEC Mini PFL webbing 1.8 m (6 ft) is specifically tested and suitable for use on MEWPs (Mobile Elevating Working
platforms) in Europe (Prüfgrundsatz PG -06-07). Injuries caused by impact with work basket or boom cannot be excluded.

V-TEC PFL top connector attached to either the full body harness or anchor point. Attach one end of the V-TEC PFL to a
suitable anchor or anchor connector, attach the other end to the designated fall arrest attachment of a full body harness.
When used on a MEWP the device shall be secured to the harness dorsal d-ring and the Lanyard connected to the basket

4

V-TEC io1 Smart Hook PFL

1 Safety Regulations

US

Содержание V-TEC io1 Smart Hook PFL

Страница 1: ...User Instructions V TEC io1 Smart Hook PFL Fall Protection Order No 10215637_r0 Print Spec CR 8000000XXXX MSAsafety com...

Страница 2: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference...

Страница 3: ...Contents 6 3 Specifications 7 3 1 Physical Specifications 7 3 2 Electrical Specifications 7 4 Installation 9 4 1 Installing the V TEC io1 9 5 Operation 11 5 1 Using the V TEC io1 System 11 5 2 Status...

Страница 4: ...nents shall not be substituted TheV TEC io1 is only to be used for its intended purpose and within its limitations Further clarification can be obtained from MSA For use in accordance with acceptable...

Страница 5: ...ontact MSA In use the V TEC io1 lifeline will extract and retract without hesitation Do not allow the lifeline to pass through legs or under arms or wrap around structure If the lifeline does not retr...

Страница 6: ...king red lights Scenario 1 After waking the hook goes into alarm in 15 seconds if no connections are found Scenario 2 After disconnection from the harness the hook alarms after 30 seconds if no new co...

Страница 7: ...5A max Output Connection Type Female USB Type A Operating Temperature 10 C to 70 C Compliance Meets SAE J 1113 Integrated Short Circuit Protection Certifications FCC Industry Canada CE WEEE RCM e Mark...

Страница 8: ...y Capacity 350mAh LiPo nom 3 7V Charge Current 350mA 1C Charging Charge Threshold 35mA For PFL Rescue Training and Inspection content related to the lanyard itself please reference included PFL manual...

Страница 9: ...cation on the control wall where the auxiliary battery pack will fit WARNING Wipe away dust and dirt from the electrical leads with degreaser and a cloth Failure to follow this warning can result in s...

Страница 10: ...the entry point into the access compartment NOTE Use the provided cable ties and peel and stick cable tie mounts as needed to control the wire path and prevent it from interfering with other component...

Страница 11: ...k does not detect motion the device will enter sleep mode The smart device on the snaphook wakes up when the RFID tag detects motion Battery Service Life When the battery has 20 service life remaining...

Страница 12: ...Inspect charging line and verify they are free of any cuts or abrasions The cables should be fully secured at the each connection point and there should be no loose portions of wire Labels Inspect la...

Страница 13: ...form a hard reset See Table 1 for status indicators Press the reset button on the side of the Smart Hook plastic housing with a small paperclip to turn it off Do this again to turn the Smart Hook back...

Страница 14: ...ITED TO THE TERMS HEREOF MSA SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Exclusive Remedy It is expressly agreed that the Purchaser s sole and exclusive...

Отзывы: