Appendix: Electrical Installation
MSA
ULTIMA X ® Series
GB
67
9
Appendix: Electrical Installation
9.1
Installation Outline Drawing [CE] - ULTIMA XE
Notes:
-
Instrument weight: 4.72 kg
-
Instrument housing: 316 St.St.
-
Dimensions shown in millimetres.
-
Install ULTIMA XE with sensor inlet pointing down.
-
Certified cable glands or blanking plugs shall be installed at all cable entries
during installation.
-
All cable shields to be terminated to ground earth at one end only.
-
NPT threads shall conform to the requirements of ANSI/ASME B1.20.1, and
shall be made-up wrench tight.
The cabling and electrical installation must be carried out based on the
instrument types used.
Electrical installation details are given in appropriate drawings.
160.3
99.3
7.6
10-32 mounting
screw holes
(2 places)
Sensor Inlet
262.2
M4 x 0.7 set screws (4 places)
for M25 x 1.5 cable gland thread only
36.6
¾″ NPT
(4 places)
73.2
Содержание ULTIMA X-Series
Страница 1: ...Operating Manual ULTIMA X Series Gas Monitors Order No 10046690 09 ...
Страница 2: ...MSA AUER GmbH Thiemannstrasse 1 D 12059 Berlin Germany MSA AUER GmbH All rights reserved ...
Страница 28: ...MSA Description ULTIMA X Series 28 GB Fig 5 ULTIMA XA Fig 4 ULTIMA Remote sensor module non reactive gas ...
Страница 69: ...Appendix Electrical Installation MSA ULTIMA X Series GB 69 9 3 Installation Outline Drawing CE ULTIMA XA ...
Страница 72: ...MSA Appendix Electrical Installation ULTIMA X Series 72 GB 9 6 HART module M6 109 45 4 309 ...
Страница 158: ...MSA Appendix HART Specific Information ULTIMA X Series 158 GB Sensor Trim Point Screen Fig 52 Sensor trim point screen ...