background image

 
 
 
 
 

Version 0.1

 

  

4

 

Computer system unit of types 
MPC-127, MPC-19-4 

1

 

DESCRIPTION AND OPERATION OF THE DEVICE 

1.1

 

D

ESCRIPTION

 

The  Product  is  designed  to  be  applied  as  a  control  computer,  component  of 

shipborne automation, navigation and surveillance devices, etc. 

1.2

 

T

ECHNICAL SPECIFICATIONS

 

1.2.1

 

Main  parameters  and  technical  specifications  of  the  Product  

are represented in Table 1. 

Table 1 – Technical specifications of the Product 

Parameter 

MPC-127 

MPC-19-4 

Значение  

CPU  

Intel Core i3, Intel Core i5, Intel Core i7, Intel Pentium 

Graphics, MB 

included, 1024, 2048, 4096, 8192 

RAM, GB 

4, 8, 16, 32 

Type and capacity of HDD, GB

 1)

 

480, 960, 2 ТБ, 4 ТБ 

Software

2)

 

Windows 7x86, Windows 7x64, Windows 10x64 

Astra Linux Special Edition 

Supported interfaces, pcs. 

1 x Audio input, audio output, microphone  

8 х USB 2.0, 2 х USB 3.0 

1 х VGA, 1 x DVI 

1 х Ethernet 10/100/1000 Base-T 

1 х COM (RS-232) 

2 x PS/2 (keyboard and manipulator) 

Supply voltage 

220 VAC, 110 VAC, 24 VDC, 12 VDC 

Max. Power consumption, W

3)

 

550 

Protection degree 

IP22 

Operating temperature, °С 

–60 … +70 

Temperature limit, °С 

–15 … +55 

Монтаж  

desk top 

19'' rack  

Type of connectors 

standard 

1)

 Specify HDD type at order (HDD or SSD). 

2)

 Another OS may be installed on request. 

3) 

Standard power characteristics. 

1.2.2

 

The Product ensures: 

–  data  processing,  reception  and  transmission  with  connected  devices  via 

interfaces; installed software control; 

–  display  of  computing  processes  on  the  screen  according  to  the  installed 

software; 

–  automatic  configuration  control  and  software  load  under  Basic  Input  and 

Output System (BIOS) when the Product is switched on and setup initially; 

– continuous operation mode; 

– performing  autonomous  operations  in  all  operating  conditions  including 

emergency ones.   

Содержание MPC-127

Страница 1: ... Company NPK MORSVYAZAVTOMATICA 26E Kibalchicha str 192174 St Petersburg Russia info unicont com www unicont com Phone 7 812 622 23 10 Fax 7 812 362 76 36 COMPUTER SYSTEM UNIT OF TYPES MPC 127 MPC 19 4 Operating Manual ...

Страница 2: ......

Страница 3: ...1 5 Marking and sealing 10 1 6 Packaging 10 2 INTENDED USE 11 2 1 Operational constraints 11 2 2 Preparation for the Product operation 11 2 1 Usage of the Product 12 3 TECHNICAL SERVICE OF THE PRODUCT 13 3 1 General instructions 13 3 2 Safety features 13 3 3 Maintenance routine 13 3 4 Preservation 15 4 INSTALLATION AND DISASSEMBLY OF THE PRODUCT 16 4 1 General description 16 4 2 Safety features 16...

Страница 4: ...components and instructions required for the Product s correct and safe operation intended use technical service current repair as well as disposal information for its components Only those who have read operational documentation shall be permitted to operate with the Product Only those who have had general education in the area of electronic devices and read operational documentation shall be per...

Страница 5: ... input audio output microphone 8 х USB 2 0 2 х USB 3 0 1 х VGA 1 x DVI 1 х Ethernet 10 100 1000 Base T 1 х COM RS 232 2 x PS 2 keyboard and manipulator Supply voltage 220 VAC 110 VAC 24 VDC 12 VDC Max Power consumption W3 550 Protection degree IP22 Operating temperature С 60 70 Temperature limit С 15 55 Монтаж desk top 19 rack Type of connectors standard 1 Specify HDD type at order HDD or SSD 2 An...

Страница 6: ...es 1 и 2 Note Overall dimensions in Figures 1 and 2 are informative and may differ from particular Product design depending on the order Inquire the manufacturer for overall dimensions of particular Product design Figure 1 Overall dimensions of the Product MPC 127 Figure 2 Overall dimensions of the Product MPC 19 4 ...

Страница 7: ...ion of the Product s connectors N Name Description Type 1 XPn 8 To connect AC voltage 220 V 50 Hz C13 XPn 9 To connect AC voltage 110 V 50 Hz C13 XSn 10 To connect DC voltage 24 V C14 XSn 11 To connect DC voltage 12 V C14 2 1 ХSn 27 To connect manipulator mini DIN 6 2 2 ХSn 27 To connect keyboard mini DIN 6 3 XSn 20 To connect universal serial interface COM RS 232 DB 9M 4 XSn 1 To connect VGA DB 1...

Страница 8: ...Pin Description 1 Data key Data mouse 2 3 Gnd 4 Vcc 5 Clock key Clock mouse 6 Table 6 Description of XSn 20 connector pins Тип разъема контакта Назначение 5 4 3 2 1 9 8 7 6 view from soldering side 1 2 RxD 3 TxD 4 5 GND 6 7 RTS 8 CTS 9 Screen Table 7 Description of XSn 25 connector pins Тип контакта Назначение view from connection side 1 5 V VCC 2 data D 3 data D 4 GND Table 8 Description of XSn 1...

Страница 9: ... 8 9 10 11 12 13 14 15 pinout of unit from side of cable connection 1 Red 2 Green 3 Blue 4 Not used 5 Common GND 6 GND_Red 7 GND_Green 8 GND_Blue 9 5 В 10 GND 11 GND 12 data SDA 13 HSYNC 14 VSYNC 15 Data synch SCL Table 11 Description of XSn 4 connector pins Type Pin Description pinout of unit from side of cable connection 1 TMDS 2 2 TMDS 2 3 TMDS 2 Sh 4 Not used 5 Not used 6 SCL 7 SDA 8 Not used ...

Страница 10: ...Рисунок 4 Layout of controls indication LEDs of the Products MPC 127 type Table 12 Control and indication description of the Products MPC 127 type N Name Description 1 O ǀ Switch to turn power on off 2 DVD RW DVD RW drive 3 Provides connection of external USB devices 4 Button switches on off the product 5 Reset button 6 Power indicator 7 HDD activity indicator Рисунок 5 Layout of controls indicati...

Страница 11: ...ean surfaces and parts of the device use clean cloth 2 To clean severe contamination use alcohol soaked cloth Rectified hydrolytic technical ethyl alcohol 0 01 l To soak cloth while removing contamination Varnish 0 05 kg To cover surfaces of the device in case of paint coating damage Abrasive cloth 0 06 х 0 06 m To polish surfaces of the device in case of paint coating damage 1 5 MARKING AND SEALI...

Страница 12: ...chnical rules for operation of electric installation and Safety rules for operation of electric installation while testing electrical circuits and insulation resistance 2 2 2 Method of the visual check Before switching the Product on the staff shall observe visually the cable integrity and initial position of the controls on the front panel clean front panels from dust and dirt by clean soft cloth...

Страница 13: ...no type switch On Off to Off position transfer a circuit breaker of main power switchboard to Off position and disconnect power cable from the Product 2 1 USAGE OF THE PRODUCT The Product is delivered with pre configured software in accordance with the order from the manufacturing plant and it is ready to be used The Product may be used to the full extent only after connection of input device disp...

Страница 14: ...emi annual TS Technical service 2 ТS 2 annual TS TS 1 TS 2 shall be provided by staff on the equipment in opera tion running 3 2 SAFETY FEATURES While providing TS the staff shall follow instructions see 4 2 3 3 MAINTENANCE ROUTINE The list of works for all types of the Technical service is given in Table 15 Maintenance routine procedure is given in the checklists CL represented in Tables 20 and 1...

Страница 15: ...d directly to the surface of the Product 4 In case of varnish damage clean it with abrasive cloth then alcohol soaked cloth cover with varnish and let dry 1 person 5 mins Check reliability of cable connections and grounding buses 1 Make sure that connectors and attaching screws are fastened tight provide further fastening if needed 2 Check integrity no mechanical damage of leading cables which are...

Страница 16: ...in preserved condition in Manufacturer s packaging boxes The time of represervation 2 years from the Manufacturer s commissioning The represervation is done in heated rooms in the same order as the preservation The represerved Product SPTA kit and documents are placed in package The time of storage 2 years ...

Страница 17: ...der repair is ON is STRICTLY PROHIBITED It is PROHIBITED to put a poster DO NOT switch on Under Operation when power supply switch is in OFF position Installation commissioning and repair works are PROHIBITED in the room where less than 2 people present 4 3 СURRENT REPAIR The service personnel can provide repair works as given in Table 18 All other defects shall be carried out only by the Manufact...

Страница 18: ...onditions 5 40 С with the concentration of dust oil moisture and aggressive impurities in the air within the required limits for the working areas of production facilities After storage or transportation of the Device below 10 С it must be unpacked only in heated premises and left in normal climate conditions for 12 hours beforehand ...

Страница 19: ... transportation in sealed and heated compartments sea transportation in dry service premises The Product must be transported in compliance with transportation rules applicable for each means of transport During loading unloading operations and transportation the requirements indicated on warning labels on the boxes packaging must be observed and no impacts are permitted since they can affect the s...

Страница 20: ...for its further disposal Proper disposal of Product components allows avoiding possible negative envi ronmental and health impacts and it also allows for proper restoration of components with substantial energy and resources saving During operation and upon completion of its service life the equipment is not hazardous for health and environment This unit must be disposed according to the rules app...

Страница 21: ...ration or service damage claims are not considered by the Manufacturer More information about warranty terms you can find on the official site of NPK Morsvyazavtomatica LLC section Support Address and contacts of the Manufacturer s service centre NPK Morsvyazavtomatica LLC 26E Kibalchicha str 192174 St Petersburg Russia Tel 7 812 602 02 64 8 800 100 67 19 fax 7 812 362 76 36 e mail service unicont...