
Luminator Cap Lamp
15
Approvals
GB
8
Approvals
8.1
Marking, Certificates and Approvals according to
the Directive 94/9/EC (ATEX)
Special conditions for safe use:
In hazardous locations the Multifunctional LED-Lamp type LUMINATOR has to
be used according to the following regulations:
-
The device has to be carried at the body. Don't put the device away out of
your supervision. This is to prevent the device from electrostatic charge.
-
The charging of the LUMINATOR is only allowed outside of the hazardous
area.
-
For charging follow the manual instructions (5 V/1 A, U
m
= 7 V).
Special conditions for safe use:
The antenna used for the activation of the transponders in an hazardous area
must only be with the RF radiation power not exceeded 6 W for Group I and 2 W
for Group IIC.
Manufacturer:
MSA AUER GmbH
Thiemannstraße 1
D-12059 Berlin
Product:
LUMINATOR
EC-Type Examination Certificate: BVS 13 ATEX E 076
Type of protection:
EN 60079-0:2012, EN 60079-11:2012
Marking:
I M1 Ex ia I Ma
II 1G Ex ia IIC T4 Ga
-20°C
Ta
+60°C
Battery:
LiFePO4 3,6 V / 9000 mAh
U
m
: 7 V
Quality Assurance Notification:
0158
Year of Manufacture:
see Label
Serial Nr.:
see Label
RFID TAG:
The instrument is installed with an pas-
sive RFID-TAG: FTZU 11 ATEX 0177 X.