39
Cleaning and Disinfecting
G1 Powered Air-Purifying Respirator (PAPR)
US
10.2 APR Adapter
WARNING!
Do NOT use cleaning products that contain hydrocarbons or solvents such as nitro-thinner.
Do NOT use radiant heat such as the sun or radiators to dry cleaned parts.
When a drying cabinet is used, make sure that the temperature is not more than 140°F (60°C).
Do a negative pressure seal test after every cleaning, disinfecting, and maintenance procedure,
and after every exchange of parts.
Failure to obey these warnings can result in serious injury or death.
(1) Use the instructions on the label to prepare a solution of
Confidence Plus Germicidal Cleaner (PN 10009971) in a
bucket or sink.
(2) Remove the adapter cover.
(3) Submerge the adapter in the solution of Confidence Plus
Cleaner for a minimum of 30 seconds. If necessary, use a
sponge or soft brush to clean the adapter.
(4) Submerge the adapter cover in the solution of Confidence
Plus Cleaner for a minimum of 30 seconds. If necessary,
use a sponge or soft brush to clean the adapter cover.
(5) Rinse the adapter and adapter cover thoroughly in clean
water that is not more than 110°F (43°C) and is preferably
running and draining.
(6) Let the adapter and adapter cover air-dry. Do NOT put
parts near a heater or in direct sunlight.
(7) Operate the exhalation valve manually to make sure that
it operates correctly.