MS Sedco DH400 Скачать руководство пользователя страница 1

DH400

High Mount Active Infrared Presence Detector for Automatic Door Control 

INSTALLATION INSTRUCTIONS

Page 1

DH400v1214

Section 1

General Description

The  DH400  is  a  high  mount  microprocessor  controlled 

active  infrared  presence  detector  for  all  types  of 

automatic doors. 

• Wide and narrow pattern width of the sensor

  is adjustable.

• Pattern depth and width are 

  adjustable using mounting height, 

  dip switches, pattern width and 

  pattern angle adjustments.

• Frequency is selectable in four channels

• Self-Diagnostic means the sensor continuously 

  monitors itself.

• Snow Mode Switch ensures against false operation 

  caused by snow, insects, etc.

• Microprocessor provides programmable Presence 

  Timer (2 sec., 30 sec., 60 sec., or infinity).

Section 2

Parts Identification

Section 3

Mounting Information

1.  Do not mount higher than 13.1 ft. (4m).

2.  Mount within 1.97” from the bottom of the 

 

door engine cover. 

3.  Do not leave any objects which may move in the 

 

detection pattern.

4.  Do not mount in a humid or steamy environment.

5.  Do not mount where rain or snow will fall directly on 

 

unit.

6.  Do not mount where snow or water will accumulate 

 

on floor if possible.

7.  Do not mount in a place where reflection of sunlight 

 

will shine on unit.

8.  Use different frequency settings for sensor in close 

 

proximity.

  To maximize the effectiveness of doorway detection,

  install the DH400 outside and inside as shown below. 

Mounting 

Template

Mounting 

Screws

Connection Cable 

8.2 ft. (2.5m)

Instructions

Installation

Accessories

Use Alternate Frequency.

1

2

3

4

5

6

7

8

A          B 

Dip Switch

Cover

13.1Ft.

NOTE: 

 Set up for this sensor should be 

performed by an AAADM-certified installer.

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Connector

Potentiometer

(Sensitivity Volume)

Indicator LED

Depth Adjustment Screw

Mounting Screw 

(2pcs.)

Detection Window

Width Adjustment Knob

A          B 

Side View

Plan View

Moving Door Leaf

Moving Door Leaf

Содержание DH400

Страница 1: ...ngine cover 3 Do not leave any objects which may move in the detection pattern 4 Do not mount in a humid or steamy environment 5 Do not mount where rain or snow will fall directly on unit 6 Do not mount where snow or water will accumulate on floor if possible 7 Do not mount in a place where reflection of sunlight will shine on unit 8 Use different frequency settings for sensor in close proximity T...

Страница 2: ...ttern Width Right Side The right side detection area for approaching direction can be fixed by setting to 6 4 or 2 rows 6 Rows 4 Rows 2 Rows Installation Height Set to installation height required NOTE Set the sensitivity after setting the mounting height Refer to Section 8 Verification of Operation regarding the standard of sensitivity corresponding to mounting height Page 2 DH400v1214 DH400 High...

Страница 3: ...econds Presence Detection Setting 5 TEST the presence feature especially near the door When carrying out the following work TURN OFF THE POWER 1 When the floor conditions change 2 Adjusting pattern or sensitivity DOORWAY LEARN is OFF Ref Sec 5 Dip Switch Settings Upon power ON the solid Green LED turns on indicating that the sensor is in standby mode and ready to detect Doorway Learn is OFF Cont P...

Страница 4: ... Learn is turned ON the sensitivity level of the inner row of detection is at maximum ONLY when the outer rows of detection are activated CAUTION If you change dip switch setting or sensitivity volume the sensor will be reest During resetting indiator LED is blinking with orange color Keep away from detection area After resetting the sensor becomes the same state as it is turned Power on In case t...

Страница 5: ...t operate properly recheck the dip switch settings and pattern adjustments 3 After rechecking if there is still a problem adjust the sensitivity Adjust high clockwise to increase sensitivity Adjust low counter clockwise to decrease sensitivity APPLY ONLY SMALL TORQUE Standard of sensitivity volume setting depending on Mounting Height Height Setting Setting Standard 6 6 2 0m 8 2 2 5m 4 8 2 2 5m 9 8...

Страница 6: ...droplet on the sensor lens SOLUTION 3 Wipe sensor lens with clean cloth and install a weather cover if necessary CAUSE 4 Detection pattern is too far from the door detecting people passing by SOLUTION 4 Adjust detection pattern CAUSE 5 Detection area overlaps with that of another sensor SOLUTION 5 Ensure different frequency setting for each sensor CAUSE 6 Detection of falling snow insects leaves e...

Страница 7: ...sions Section 13 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for 3 years from date of installation Unless MS SEDCO is notified of the date of installation the warranty will be in effect for 3 years from the date of shipment from our factory If during the first 3 years our motion detector or support device fails to operate and has not been tampered with our abuse...

Страница 8: ... dia 10mm O 39 2 Be sure to stick this mounting template with its bottom adjusted parallel to the same position as the bottom edge of E the engine cover E E f5 Mount within 50mm 1 97 above the bottom edge of the engine cover Bottom Position of Engine Cover Center l MOUNTING TEMPLATE I SP 10224 I E f5 ...

Отзывы: