451-0331
MRV Communications, Inc.
www.mrv.com
53
Appendix C - POST Test Error Codes
POST Test Error Code Sample
NOTE:
This example applies to 20 and 40 port LX-8000 units. The 20 and 40 port LX
units use only the first eight LEDs when generating error codes.
The following sample illustrates the Port Status LED sequence for Error 2030 (Reading Invalid Value
from PLD System Fail Status Register) on the LX-8020. In this example:
1. A POST test failure occurs on an 20-port unit. All LEDs flash eight times, very quickly, then the error
code is displayed.
2. You record that LED 3 turns on. Again, all LEDs flash eight times very quickly, then the rest of the error
code is displayed.
3. You record that LEDs 3 and 4 turn on. Figure 15 explains how to interpret the sample error code.
NOTE:
In hexadecimal, 0 indicates the LED is OFF. 1 indicates the LED is ON.
Each group of four LEDs is converted to a hexadecimal value as follows:
•
0 = 0000
•
1 = 0001
•
2 = 0010
•
3 = 0011
•
4 = 0100
•
5 = 0101
•
6 = 0110
•
7 = 0111
•
8 = 1000
•
9 = 1001
•
A = 1010
•
B = 1011
•
C = 1100
•
D = 1101
•
E = 1110
•
F = 1111