User manual

 

DELTA

smart

 

 

MRU GmbH, D-74172 Neckarsulm 

23 / 50

 

 

 
 
 
 
 
 
 
 

5.6.

 

Select fuel types and O

2

 reference 

After selecting a measurement program, you can select or add fuel types. You 
can define what fuel types you want to see for each measurement program by 
using the fuel type list.  
Select the 

context menu

 key and then select 

fuel type list

.  

 
 

 

 

 
 
 

 

 

5.7.

 

User definable fuel types 

There are 4 user definable fuel types available. These can be individually 
adjusted; fuel type parameters can be set. Just as all other fuel types 
these fuel types can be activated or deactivated for usage. 
 

 

NOTE

 

The user definable fuel types are the last in the fuel type 
list and they are clearly displayed in green. 

 

5.8.

 

Define the measuring window 

The 

DELTA

smart

 

can display 20 measurement values 

 4 values on 5 

pages. The user can define in what order he wants to see the available 
measurement values.  
Please select 

MEASURING WINDOW

 CONTEXT MENU 

 DEFINE 

WINDOW

. You will then select the line that needs to be modified and 

with left and/or right you can view and select available parameters. This 
procedure will be done for each line. 
 
 

 

Add fuel 
type

 

2  Adjust O

2

 

reference 

 

 

Содержание DELTAsmart

Страница 1: ...User manual DELTAsmart MRU GmbH D 74172 Neckarsulm 1 50 6902EN N...

Страница 2: ...r manual 2020 by MRU No part of this manual my be published in any form print fotocopy electronic media or any other publication form without a written approval by the publisher All user trade marks a...

Страница 3: ...ion 15 4 1 Power on and power down 15 4 2 Function keys 15 4 3 Context menu 15 4 4 Combustion test 16 4 5 Draft pressure measurement on combustion test 17 4 6 Display 19 4 7 Menu structure 19 5 First...

Страница 4: ...ient air 31 7 11 After each measurement 32 8 Data Storage 33 8 1 Organizing data storage 33 8 2 Data storage information 33 8 3 Sites administration 33 8 4 Data transfer using the SD card 34 8 5 Measu...

Страница 5: ...DANGER Describes an immediate threat of danger which can cause mayhem or can even cause death WARNING Describes an immediate threat of danger which can cause mayhem property damage or can even cause...

Страница 6: ...tube and or thermo element can be destroyed 1 4 Analyzer details The analyzer is not suitable for long term continuous measurements this is a spot analyzer Before using the analyzer verify the condit...

Страница 7: ...harge the analyzer in extreme heat don t store the battery in a hot environment and don t throw the battery into fire Don t try to modify the battery shortcut it or put any me chanical force to it The...

Страница 8: ...mission control measurements and adjustments at small furnaces The analyzer measures the measurements provided by VDI4206 and EN50379 met rics and stores them for further processing The DELTAsmart ana...

Страница 9: ...ing high quality emission monitoring analyz ers MRU GmbH produces a wide range of instruments from standard analyz ers up to tailor made industrial analyzers MRU GmbH contact details are listed on the...

Страница 10: ...ardous material Waste Disposal Returns Warranty MRU GmbH is required to accept the re turn of hazardous waste such as electro chemical sensors that cannot be dis posed of locally Hazardous waste must...

Страница 11: ...schematics diagram In combination with the extraction probe inserted in the stack the in ternal gas pump of the DELTAsmart analyzer extracts a portion of the flue gas and analyzes it using electro che...

Страница 12: ...he touch screen display 1 Touch screen display 2 Connection port P2 for draft measurement 3 Temperature port T2 for gas temperature 4 Connection port P1 only for differential pressure measurement 5 Te...

Страница 13: ...rked with a ring on the bot tom part of the show glass Empty the condensate separator frequently to avoid water getting into the analyzer See also chapter 6 6Controlling condensate separator water tra...

Страница 14: ...ilable probe options can be found in our effective price list Here are 2 possible options Extraction probe Extraction probe With 250 mm fixed probe tube and 1 5 m sampling line With 180 or 300 mm exch...

Страница 15: ...pressure 4 2 Function keys In all operation windows there are pre defined function keys at the top and the bottom of the screen At the top of the screen these are mostly the return key and the con te...

Страница 16: ...haust outlet at the rear of the analyzer may never be covered during a measurement never oper ate the analyzer in a transport case Start starts a combustion test with the current selected program and...

Страница 17: ...ill be displayed These val ues can be carried over as either draft or pressure value into the gas measure ment screen The difference between these 2 values are basically the pre sign and name before t...

Страница 18: ...Connection for draft measurement 1 Temperature port T2 for gas temperature 2 Temperature port T1 for ambient air temperature 3 Connection port flue gas entrance 4 Connection port P1 not used for draf...

Страница 19: ...asurement related functions available All installed and available measurement options can be se lected here Storage menu Here all storage related functions are available like site ad ministration data...

Страница 20: ...U GmbH D 74172 Neckarsulm DELTAsmart The Measure ment menu is described in 7 Performing measure ment Page 29 The Storage menu is de scribed in chapter 8 Data Storage Page 33 The Extras menu is de scri...

Страница 21: ...be made LCD brightness Language Country for country specific fuel types and measuring functions Helping hints on off Keyboard beep on off Temperature units Country Option By changing the country the O...

Страница 22: ...bient Combustion test sub menu Test program This is used to check the analyzer with test gases without the selec tion of a fuel type third party testing Modifications of these programs can be made onc...

Страница 23: ...rs can be set Just as all other fuel types these fuel types can be activated or deactivated for usage NOTE The user definable fuel types are the last in the fuel type list and they are clearly display...

Страница 24: ...u Extras you can select the 6 lines measuring window The DELTAsmart can display 18 measurement values 6 values on 3 pages 5 10 Select and modify the Bluetooth parameters The following software can be...

Страница 25: ...r higher is needed for iOS Adjustments can be made in the main menu EXTRAS sub menu Set tings sub menu Bluetooth There are two selections available ANDROID and iOS BLUEGAZsmart must be OFF Additional...

Страница 26: ...e external USB charger 90 260 V 50 60Hz During battery charging the analyzer can be operated and be used for measurements Once the battery is fully charged the analyzer will switch to trickle charge m...

Страница 27: ...ave encountered acid Here is how to empty the condensate separator Move the hoses from the upper bracket to the side Unscrew upper plug counter clock wise then lift it Empty the container with caution...

Страница 28: ...stack During zeroing there is a blue zeroing bar top of display visible Once zeroing is completed the blue bar will disappear and the DELTAsmart is ready for measurement The analyzer will display a d...

Страница 29: ...described in chapter 4 4 Measurement values are available as direct measured like O2 and tem perature as well as calculated values like CO2 and efficiency Some val ues are available with different pa...

Страница 30: ...ed number of lines e g city address etc 7 6 Ending a measurement A measurement can be stopped at any time using the Stop Button The window changes its color and the values are frozen All values that h...

Страница 31: ...temperature differential measurement 2 temperatures can be measured Both measured values will be displayed using port T1 and T2 as well as the difference of these values will be displayed NOTE The acc...

Страница 32: ...appropriate sticker tape CAUTION HOT danger of burns and fire hazards from gas ex traction probe Physical harm and property damage can be caused Cool down the probe tube ATTENTION Thermo element can b...

Страница 33: ...rred identi fied by the site number that has been assigned to the measurement when the measurement was saved 8 2 Data storage information In the menu storage and sub menu Memory info the number of sto...

Страница 34: ...ed values CSV file is a simple text format for a database table Each record in the table is one line of the text file Each field value of a record is separated from the next by a character The analyze...

Страница 35: ...you could face problems with double site numbers when exporting them again to a computer program see also 3 4 Export of Measure ments However the analyzer marks the files that have been im ported succ...

Страница 36: ...as the soot numbers Derivate and T Boiler Example 8 5 Measurements in Data storage View measurements In the sub menu view measurements saved measurements can be viewed When selected First the number o...

Страница 37: ...read your software documentations or ask your software dealer 8 6 Data transfer to the PC Sweeping district management pro grammes What is necessary for a data transfer to a sweeping district man age...

Страница 38: ...ulm How do I have to install the MRU ZIV module The software MRU ZIV module can be found on the MRU product CD in the Software folder During installation the manual for the MRU ZIV module is stored on...

Страница 39: ...arameters will be reset to factory settings Parameters for measurement that have been modified by the user will be set to factory settings again Settings LCD brightness 50 Helping hints ON Keyboard be...

Страница 40: ...ed on the tip of the probe tube NOTE With dirt and soot particles on the probe tube the test cap will not seal properly The probe tip must be cleaned before you start this test Test leak tight lest wi...

Страница 41: ...sam pling from the DELTAsmart and let them dry condensate inside the hoses Open and empty the condensate separa tor and let it dry Occasionally clean the sampling line The pleated filter in the conde...

Страница 42: ...ht w 2 sensors ca 500g 1 1 lbs Size 160 x 82 x 44 mm 6 3 x 3 2 x 1 7 in Housing material PA6 IP degree of protection IP30 Max suction range gas pump 150 hPa gas flow typ 20 l h Measurement values Elec...

Страница 43: ...1 000 ppm 10 1 000 ppm Response Time T90 50s Temperature measurement T1 T2 Number of thermocouple type K input 2 Measuring Range 40 C 1 200 C 2 C Accuracy abs reading 0 50 Flue gas temperature using M...

Страница 44: ...Measurement range 0 999 PI Poison Index Ratio Measurement range 0 0001 10 0 Dewpoint F Losses qA Measurement range 0 99 9 Efficiency Measurement range 0 120 Measurement can be displayed as Mg Nm3 O2 R...

Страница 45: ...fgas Test gas 0 0 0 00 0 00 0 000 Erdgas LL Natural gas LL 11 8 0 37 0 66 0 009 Erdgas E Natural gas E 12 1 0 37 0 64 0 009 Heiz l EL Oil EL 15 4 0 50 0 68 0 007 Heiz l S Oil S 15 9 0 50 0 66 0 007 Fl...

Страница 46: ...in a sub folder IMPORTANT Please make sure that your battery has at least 60 capacity when making an update Perform an update Insert the SD card into the analyzer SD card slot the SD card pins must f...

Страница 47: ...oks good but you still don t get any readings Wrong Com bustion Test re sults O2 values are too high CO and CO2 val ues are too low Bad probe connec tion leaking con densate separator or gas pump not...

Страница 48: ...User manual DELTAsmart 48 50 MRU GmbH D 74172 Neckarsulm 11 5 O Ring Set for DELTAsmart 65875 O Ring Set Condensate separa tor 65622 Seal filter side 65627 Seal show glass side 65628...

Страница 49: ...User manual DELTAsmart MRU GmbH D 74172 Neckarsulm 49 50 12 Declaration of conformity...

Страница 50: ...User manual DELTAsmart 50 50 MRU GmbH D 74172 Neckarsulm...

Отзывы: