1

 

Introduction 

 

This manual is an important part of your delivery. It explains the usage and 
purpose of the Hand Detector Probe 400DH. 

 

Please read this manual carefully and make yourselves familiar with the Hand 
Detector Probe 400DH before using it. 

 

The Hand Detector Probe 400DH may only be used by skilled personnel and 
may only be used for its intended purpose. 

 

Please pay special attention to the security and warning signs, to avoid per-
sonal injuries and damaging the product. 

 

MRU can’t be held responsible for damages or injuries, by mot following the instruc-
tions in this manual. 

 

Always keep the manual near you when working with the analyzer, to be able 
to read instructions as needed. 

 

1.1.

 

Intended Usage 

The hand detector probe 400DH cannot be used for personal protection or con-
tinuous monitoring tasks! 
 
The hand detector probe 400DH is available with different interchangeable sen-
sor heads and can be used: 
 

 

Gas Leak detector to detect gas leaks in an installation area 

 

Spillage test to locate leaks at flue pipes 

 

  

The hand detector probe 400DH detects measurement components and dis-
plays them. 

 
The instrument was manufactured according relevant norms and regulations. It 
must be used within its intended use. 

 
The hand detector probe 400DH may not be modified from the design or safety 
engineering. 
Modifications of any kind by the user will render the declaration of conformity

 
 

 

 

 

 

 
 

 

This hand detector probe meets the requirements of the 

valid European and national regulations. 
You can find the declaration of conformity in the appendix 

Содержание 400DH

Страница 1: ...USER MANUAL 400DH MRU GmbH D 74172 Neckarsulm 1 14...

Страница 2: ...manual 2019 by MRU No part of this manual may be published in any form print photocopy elec tronic media or any other publication form without a written approval by the publisher All user trademarks...

Страница 3: ...manual 6 3 Description 7 3 1 The hand detector probe 400DH 7 3 2 Terms and window designation 8 3 3 Context menu 8 4 Interchangeable sensors with technical specs 9 4 1 Leak detection on gas installat...

Страница 4: ...e able to read instructions as needed 1 1 Intended Usage The hand detector probe 400DH cannot be used for personal protection or con tinuous monitoring tasks The hand detector probe 400DH is available...

Страница 5: ...cing and marketing high quality emission monitoring analyzers MRU GmbH manufactures a wide range of instruments from standard analyzers up to tailor made industrial analyzers Plant 1 Sales Service R D...

Страница 6: ...ions 2 2 Safety manual The used categories of safety precautions are here explained once more DANGER Identifies an immediate impending hazard that if ignored will result in severe bodily injuries or d...

Страница 7: ...match Select the menu item 400DH ext probe in the measuring device Connect sensor is displayed The hand detector probe 400DH alone does not support measurement Each measurement function is implemente...

Страница 8: ...ion explanation Signal ON Key F1 If the sensor has a signal threshold signal ON appears in the context menu and on the display Key F1 With this function the signal is switched on Signal OFF Key F1 If...

Страница 9: ...he sensor is zeroed Max 0 Key F3 The value Max is set to zero Setting Setting units and Signal thresholds Printout Dr Printout is generated a printer is required for this function Meas menu ESC Exit m...

Страница 10: ...With this function the signal is switched on Signal ON Key F1 With this function the signal is switched off Max 0 Key F3 The value Max is set to zero Reset This function resets the graphic Measuremen...

Страница 11: ...to zero Setting Setting units Printout Dr Printout is generated a printer is required for this function Meas menu ESC Exit measuring program Info The information sensor name page number firmware vers...

Страница 12: ...menu function explanation Signal ON Key F1 With this function the signal is switched on Signal ON Key F1 With this function the signal is switched off Max 0 Key F3 The value Max is set to zero Reset T...

Страница 13: ...nction the signal is switched off Zero point Key F2 With this function the sensor is zeroed Max 0 Key F3 The value Max is set to zero Reset This function resets the graphic Setting Setting units and s...

Страница 14: ...USER MANUAL 400DH 14 14 MRU GmbH D 74172 Neckarsulm 5 Declaration of conformity...

Отзывы: