background image

Your purchase of this
AC/DC MAGNETIC
METER marks a step
forward for you into the
field of precision
measurement. Although 
this AC/DC MAGNETIC
METER is a complex and
delicate instrument,
its durable structure will
allow many years of use
if proper operating
techniques aredeveloped.
Please read the following
instructions carefully
and always keep this
manual within easy
reach.

AC/DC MAGNETIC METER

Model : PMG-302

 OPERATION MANUAL

3, Hagavish st. Israel 58817   Tel: 972 3 5595252, Fax: 972 3 5594529

  

 

[email protected]

 

MRC.5.21

Содержание PMG-302

Страница 1: ...lex and delicate instrument its durable structure will allow many years of use if proper operating techniques aredeveloped Please read the following instructions carefully and always keep this manual...

Страница 2: ...SPECIFICATIONS 2 3 FRONT PANEL DESCRIPTION 4 4 MEASURING PROCEDURE 5 4 1 DC AC magnetic field measurement 6 4 2 Data Hold 7 5 ADVANCED SETTING 7 5 1 Select the magnetic field unit to mT or g 7 6 BATTE...

Страница 3: ...000 0 G 30000 G AC Range 1500 0 G 15000 G Resolution 0 01 0 1 mT 0 1 1 G N pole S pole indicator Zero button for DC magnetic function Microprocessor circuit assures maximum possible accuracy provides...

Страница 4: ...T x 0 1 mT Range G Range 1 1 500 0 G x 0 1 G Auto Range Range 2 15 000 G x 1 G Accuracy DC 5 rdg 10 digit at 23 5 AC 5 rdg 20 digit at 23 5 Frequency AC measurement Response 50 Hz 60 Hz Sensor Hall se...

Страница 5: ...n Main instrument all in one Probe 170 x 40 mm 62 x 4 5 mm 6 8 x 1 6 inch 2 48 x 0 18 inch Accessories Instruction manual 1 PC Included Above specification tests under the environment RF Field Strengt...

Страница 6: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 Display 3 5 Probe Sensing Head 3 2 Power Button 3 6 Battery Compartment Cover 3 3 Hold Button 3 7 Probe Sensor Cover 3 4 Range Button 4...

Страница 7: ...C measuremen range is autorange whan the meter measuremen velur 300 00 mT measuremen range auto change to 3000 0 mT range AC measuremen range is autorange whan the meter measuremen velur 150 00 mT mea...

Страница 8: ...meter due to the environment interference the display may show certain values not zero value it is normal Before the measurement fix the probe at the exact position by pressing and holding the HOLD Bu...

Страница 9: ...t to mT or G 0 magnetic field unit is mT 1 magnetic field unit is G 2 After Display unit is selected to mT or G press the Enter Button 3 3 Fig 1 will save the setting function with default 6 BATTERY R...

Страница 10: ...U system is hold for example the key button can not be operated Then make the system RESET will fix the problem The system RESET procedures will be following method Please remove the battery cover the...