background image

N Gauge Synchronized

Diesel Sound Decoder with

19 Accessory Sound Functions

Item #0001636

Thank you for purchasing our highly advanced DCC locomotive
sound decoder. Combined with any DCC System, our new
decoder with authentic diesel sound truly will make your model
railroad come to life.

Synchronized diesel prime mover with randomly

associated locomotive sounds

User selectable 15 different horns and 8 bells

19 accessory functions allowing more sound control

than ever

Programmable individual sound volumes

0.75 amp capacity

Programmable for either 2-digit (1-127) or 4-digit

(1-9999) addresses

Programmable start voltage

Programmable acceleration rate

Programmable deceleration rate

Programmable top voltage

Programmable 14, 28, 128 speed steps

Selectable factory default speed curve

Directional lighting (FO) at 0.2 amp rate

Supports advanced consisting (CV19)

Supports programming on the main (OPS mode)

Compatible with NMRA DCC standards

Complies with Part 15 of FCC

13x18mm speaker included

PCB size: 70 x 9.2 x 5.8mm

• 

 Directly replaces most Atlas N scale loco’s PC boards

Note: Bell, Dynamic Brake and Rail Wheel Clack cannot play at the same time. If you
active the Bell sound [F1], while either the Dynamic Brake or Rail Wheel Clack
sounds are activated, the Bell sound will override the other 2 sounds. Rail Wheel
Clack cannot play while the loco is in idle. When you turn off Dynamic brake and
Rail Wheel Clack sound there will be one second delay.

TROUBLE SHOOTING

The MRC 0001636 N diesel sound decoder should perform well with all DCC
systems. See your DCC system manual to learn how to program and operate the
decoder. For more information about register/CVs and their functions, please
refer to the NMRA DCC Standard & Recommended practices, RP-9.2.2 this is
available directly from the NMRA or their website at 

www.nmra.org.

Due to the nature of all sound decoders, the CV read back is not 100% correct. So
this feature is not supported in the decoder. This is not a defect of the decoder or
your DCC system.

Whenever the decoder doesn’t work please use program track to re-program the
loco address or program CV# 125 with value 1 to restore the decoder to factory
setting. This should bring the decoder to life.

FCC COMPLIANCE

This device complies with the part 15 of FCC rule. Operation is subject to the
following two conditions. (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interfer-
ence that cause undesired operation.

RETURN PROCEDURE

If it should become necessary to return your decoder, unplug the decoder and
return the decoder only. Please include a letter (printed clearly) with your name,
address, a daytime telephone number, and a detailed description of the problem
you are experiencing. Please also include a $15.00 check for shipping and
handling. 

Be certain to return only the decoder.

Send the decoder to:

Model Rectifier Corporation
Attn: Parts & Service
80 Newfield Avenue
Edison, NJ 08837-3817 U.S.A

PROGRAMMING

This decoder supports all programming methods including: register, paged CV,
direct CV, and programming on the main (ops mode programming).

 2005 MODEL RECTIFIER CORPORATION

80 NEWFIELD AVENUE

EDISON, NJ 08837-3817

NOTE: 

Due to limitations in older DCC systems, some of the sound functions or

light effects functions may not accessable. ALSO, you might be limited to
factory default CV values.

Printed in USA

CV

Re gis te r

De s c ription

Ra nge

De fa ult

C V1

R 1

Sh o rt  a d d re s s

1 -1 2 7

3

C V2

R 2

Sta rt  vo lta g e

0 -3 2

0

C V3

R 3

Acce le ra tio n

0 -3 2

0

C V4

R 4

D e ce le ra tio n

0 -3 2

0

C V5

---

To p   vo lta g e

0 -3 2

3 2

---

R 6

Pa g e   n u m b e r

---

---

C V2 9

R 5

Ba s ic  co n fig u ra tio n

---

2

C V7

R 7

Ma n u fa ctu re r  ve rs io n   n u m b e r

---

3 2

C V8

R 8

Ma n u fa ctu re r  ID

---

1 4 3

C V1 7

---

L o n g   a d d re s s   u p p e r  b yte

1 9 2 -2 3 1

1 9 2

C V1 8

---

L o n g   a d d re s s   lo w e r b yte

0 -2 5 5

3

C V1 9

---

Ad va n ce d   co n s is t  a d d re s s

0 -1 2 7

0

C V4 9  So u n d   o n /o ff   (1 =o n )  0 -1  1
C V5 0

---

H o rn   typ e

0 -1 5

4

C V5 1

---

H o rn   vo lu m e

0 -3

3

C V5 2

---

Be ll  typ e

0 -9

3

C V5 3

---

Be ll  vo lu m e

0 -3

3

C V5 4

---

Be ll  rin g   ra te

0 -5 0

3

C V5 5

---

D ie s e l ru m b le  vo lu m e

0 -3

3

C V5 6

---

Bra ke   s q u e a l  vo lu m e

0 -3

3

C V5 7

---

D yn a m ic  b ra ke   vo lu m e

0 -3

3

C V5 8

---

Air  re le a s e   vo lu m e

0 -3

3

C V5 9

---

Air  p u m p   vo lu m e

0 -3

3

C V6 0

---

Sa fe ty  p o p   va lve   vo lu m e

0 -3

3

C V6 1

---

En g in e   co o lin g   fa n   vo lu m e

0 -3

3

C V6 2

---

C o u p lin g   vo lu m e

0 -3

3

C V6 3

---

R a n d o m   n o is e   vo lu m e

0 -3

3

C V6 4

---

R a il  w h e e l cla ck

0 -3

3

C V1 0 5

---

U s e r  id e n tifica tio n   n u m b e r

0 -2 5 5

0

C V1 0 6

---

U s e r  id e n tifica tio n   n u m b e r

0 -2 5 5

0

C V1 1 5

---

Au to  b ra ke   s q u e a l  e n a b le /d is a b le

0 -1

1 (e n a b le )

C V1 1 6

---

C o u p lin g   s o u n d   typ e

0 -2 ,  2 =o ff

1

C V1 1 7

---

L ig h ts   e n a b le /d is a b le

0 -1

1 (e n a b le )

C V1 1 9

C o u p lin g   fire  vo lu m e

0 -3

3

C V1 2 0

Bra ke   re le a s e   vo lu m e

0 -3

3

C V1 2 1

ra n d o m   n o is e  e n a b le

0 -1

1 (e n a b le )

C V1 2 2

D ie s e l  s o u n d   typ e  (0 =o ff,  1 =rp m   & 

n o tch   s yn ch ro   to  s p e e d ,  2 =lin e a r  rp m  

s yn ch ro   to   s p e e d ,  3 =n o tch   u p /d o w n  

(F8 =n o tch   d o w n ,  F9 =n o tch   u p ))

0 -3

1

C V1 2 4

Sp e e d   cu rve   s e le ct  (0 =lin e a r,  1 =s lo w  

in cre a s e   a t  s lo w  s p e e d ,  2 =fa s t 

in cre a s e   a t  s lo w   s p e e d

0 -2

0

C V1 2 5

---

Fac tory  def ault s etting: Programming to 1 

wi

ll res tore all CV 's  to def ault s etting 

--- 0

C V2 1  ---  0

When CV 21=0,  all ac c es s ory f unc tion

s will

 

f ollow  its  ow n addres s . When CV 21=1, all 

f unc tions  

wi

ll f ollow the c ons is t addres s

---

Отзывы: