3 Product description
18
BA5789879-01 EN
The signal pin has a cap that can be screwed off so that the protective cover
can be removed from the device flange. The signal pin has different colors
depending on the type and suitability of the gasket materials for various insu-
lation fluids in the transformer/on-load tap-changer:
▪ Red (anodized) for mineral oil
▪ Blue (anodized) for silicone oil, pyranol or similar
The optional micro-switches for the signaling contacts are encapsulated,
physically separate from the functioning part of the valve and therefore pro-
tected against environmental influences and leaking oil.
3.3.1 Pressure relief device with standard protective cover
The following graphic shows the key parts of the pressure relief device:
Figure 1: Pressure relief device with standard protective cover
1 Device flange
2 3 housing screws M6x10, wrench
size 10
3 Seal (axial) with sealing lip (radial)
4 Ground connection (only with plug
connection)
5 Spring assembly
6 Cable bushing M20x1.5 for cable
diameter 8…15 mm; alternatively
without, with terminal box, with
ANSI plug or with Westinghouse
plug
Содержание MESSKO MPREC