5 Mounting
29
BA5789879-01 EN
Closing the device
After mounting, proceed as follows:
1. If the device is equipped with micro-switches for remote transmission of
the signals, first connect these micro-switches, see Electrically connecting
the pressure relief device [
2. Place the protective cover onto the pressure relief device such that the
drill holes for the fixing screws in the protective cover are aligned with the
corresponding threaded holes in the device.
3. To secure the protective cover, screw in the 2 screws, wrench size 10, on
the stand plate, and the screw, wrench size 10, on the opposite side, with
a maximum torque = 12 Nm.
Establishing operational readiness
1. Screw the signal pin cap, wrench size 32, onto the signal pin, wrench size
12, with max. torque = 8 Nm.
2. Push the signal pin into the device as far as it will go.
3. If the device is equipped with a semaphore, fold this down so that its lower
edge is perpendicular to the signal pin.
ð
This ensures that the pressure relief device is visibly in the operating posi-
tion.