12 Technical data
Maschinenfabrik Reinhausen GmbH 2019
385
5163667/06 EN
ETOS
®
IM
12 Technical data
12.1 Voltage supply
G1 PULS QS3.241
Permissible voltage range
85 to 276 V AC
88 to 375 V DC
V
N
: 100 to 240 V AC
V
N
: 110 to 300 V DC
Permissible frequency range
50/60 Hz
Nominal power consumption
55 W
Maximum power consumption (continuous)
70 W
Table 122: Voltage supply
12.2 Voltage supply
OT1205 (MR/N)
Permissible voltage range
85 to 265 V AC / V DC
V
N
: 100 to 240 V AC
V
N
: 100 to 220 V DC
Permissible frequency range
50/60 Hz
Power consumption
55 W
Internal fuse (2x)
250 V; 2 A; 5 x 20 mm, "delayed-action"
characteristics
Table 123: Standard design with wide range power supply
Figure 259: Internal fuse (2x) of wide range power supply in assembly OT1205