8 Operation
Maschinenfabrik Reinhausen GmbH 2018
151
5252433/02 EN
ECOTAP
®
VPD
®
CONTROL PRO
Acknowledging events
Acknowledgeable events must be acknowledged in the event overview so
that they are no longer displayed. All other events are automatically removed
once the cause is remedied (e.g. limit value no longer infringed).
To acknowledge the events, proceed as follows:
► To acknowledge the events, highlight the desired events in the
column
then press the
Acknowledge
button.
ð
The events are acknowledged.
8.14.2 Configuring events
The events have the following properties:
Property
Description
Event status
Active: Event active.
Inactive: Event not active.
High active
(not configurable)
High active: The device issues a signal if the event is ac-
tive.
Low active: The device issues a signal for as long as the
event is not active. If the event is active, the signal is re-
set.
Can be set multiple
times
(not configurable)
The event can be triggered several times without having
been deactivated in the meantime.
Acknowledgeable
(not configurable)
Acknowledgeable events must be acknowledged in the
event overview so that they are no longer displayed. All
other events are automatically removed once the cause is
remedied (e.g. limit value no longer infringed).
Event name
Brief name of event. If you delete all of the text, the stan-
dard text is displayed.
Event description
Description of event. If you delete all of the text, the stan-
dard text is displayed.
Event remedy
Troubleshooting information for cause of event. If you
delete all of the text, the standard text is displayed.
Category
▪ Error (red)
▪ Warning (yellow)
▪ Info (grey)
This setting affects the color of the
Alarm
LED and the
event symbol in the primary navigation.
Message
If you activate this option, the event is shown on the dis-
play and, if configured accordingly, issued via an output
and the control system protocol.
Storage
If you activate this option, the event is stored in the event
memory.
Table 52: Properties of events