Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

Mr. Heater, 4560 W. 160

TH

 ST., CLEVELAND, OHIO 44135 · 800-251-0001

2016 -70810 - CB

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. 

UNVENTED LP-GAS FIRED ROOM HEATER

MHVFIH10LPT

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Model #

Blue Flame Ice House Heater

MHVFIH10LPT

 

WARNING:

 If the information in this manual is not followed exactly, a fi re or explosion may result causing 

 

property damage, personal injury, or loss of life. 

- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

 

• Shut off gas supply

 

• Do not try to light any appliance

 

• Do not touch an electrical switch; do not use any phone in your building.

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

 

• If you cannot reach your gas supplier, call the fi re department.

- Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.

WARNING

: This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and 
Ventilation section on page 4 of this manual. 

WARNING

: Improper installation, adjustment, alteration, service or maintenance can cause injury or property 

damage. Refer to this manual for correct installation and operational procedures. For assistance or additional 
information consult a qualifi ed installer, service agency, or gas supplier. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited 
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not 
convertible for use with any other gas. 

Содержание MHVFIH10LPT

Страница 1: ...pliance Do not touch an electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach yo...

Страница 2: ...eld conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous Do not place clothing or other...

Страница 3: ...air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and let cool before s...

Страница 4: ...maller than defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code...

Страница 5: ...space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You...

Страница 6: ...18 inches above floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next...

Страница 7: ...s firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry Note Wall anchors mounting scr...

Страница 8: ...ff valve union and plugged 1 8 NPT tap Locate NPT tap within reach of test gauge hookup NPT tap must be upstream from heater see figure 11 A CSA AGA certified equipment shutoff valve with 1 8 NPT tap...

Страница 9: ...front panel OPERATING YOUR HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury o...

Страница 10: ...rth while depressed until pilot lights 7 Keep control knob depressed in for ten 10 seconds after lighting pilot If pilot goes out repeat steps 4 5 6 and 7 If pilot does not stay lit refer to Troublesh...

Страница 11: ...ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed...

Страница 12: ...turn more 5 a Contact local gas company b Clean ODS pilot see Cleaning and Maintenance page 11 6 Replace thermocouple 7 Replace Control valve Burner does not light after ODS pilot is lit 1 Burner orif...

Страница 13: ...ng Gas Connections page 9 2 Replace control valve Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See WARNING statement at top of page 1 Take apart gas tubing a...

Страница 14: ...bly w Thermocouple LP 1 20 80081 Thermostat Valve 1 8 80017 Burner Assembly 1 21 80019 Ignitor Pulse 1 9 80009 Orifice 1 22 80014 Ignitor Wire 1 10 80069 Burner Right Bracket 1 23 8001 1 Ignitor Brack...

Страница 15: ...15 Installation Instructions and Owner s Manual Unvented Liquid Propane Fired Room Heater PAGE LEFT INTENTIONALLY BLANK...

Страница 16: ...D WARRANTY Mr Heater warrants its heaters and accessories to be free from defects in material and workmanship for a period of 5 year from date of purchase Mr Heater will repair or replace this product...

Отзывы: