Mr. Heater MHVFBF20 LPBT Скачать руководство пользователя страница 1

MR. HEATER, INC., 4560 W. 160

TH

 ST., CLEVELAND, OHIO 44135 · 800-251-0001

WARNING:

 If the information in this manual is not followed exactly, a fi re or explosion may result causing 

property damage, personal injury, or loss of life. 

- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

 

• Shut off gas supply

 

• Do not try to light any appliance

 

• Do not touch an electrical switch; do not use any phone in your building.

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

 

• If you cannot reach your gas supplier, call the fi re department.

- Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.

WARNING

: This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. 

Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion 
and Ventilation section on page 4 of this manual. 

WARNING

: Improper installation, adjustment, alteration, service or maintenance can cause injury or property 

damage. Refer to this manual for correct installation and operational procedures. For assistance or additional 
information consult a qualifi ed installer, service agency, or gas supplier. 

2016 - CB

UNVENTED LP-GAS FIRED ROOM HEATER

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Blue Flame Heaters

MHVFBF20 LPBT

(BLOWER INCLUDED)

MHVFBF20 LPT

(BLOWER SOLD SEPARATE)

MHVFBF30TB LPBT

(BLOWER INCLUDED)

MHVFBF30T LPT

(BLOWER SOLD SEPARATE)

Plaque Heaters 

MHVFRD20 LPBT

(BLOWER INCLUDED)

MHVFRD20T LPT

(BLOWER SOLD SEPARATE)

MHVFRD30 LPBT

(BLOWER INCLUDED)

MHVFRD30T LPT

(BLOWER SOLD SEPARATE)

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited 
by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not 
convertible for use with any other gas. 

Содержание MHVFBF20 LPBT

Страница 1: ...tallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional informa...

Страница 2: ...IAL MEDIA WARNINGS IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death fr...

Страница 3: ...hr 2 931W shall not be installed in a bedroom or bathroom 3 Keep all air openings in heater clear free of debris or any blockage This will insure that enough air for proper combustion enters the heate...

Страница 4: ...The following are excerpts from National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classific...

Страница 5: ...Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support...

Страница 6: ...arances from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all ap pliance in b...

Страница 7: ...bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the fl...

Страница 8: ...tom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening...

Страница 9: ...g into heater If sediment trap is not installed or is installed improperly heater may not run correctly Pressure Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From regulated LP t...

Страница 10: ...ny phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can not reach your gas supplier call the fire department C Use only y...

Страница 11: ...a qualified service person of gas supplier for repairs If control knob does not pop up when released contact a qualified service person or gas sup plier for repairs 8 When the pilot is lit turn contr...

Страница 12: ...e and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position usin...

Страница 13: ...gulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in long...

Страница 14: ...ee Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1...

Страница 15: ...Installation Instructions and Owner s Manual Unvented LP Gas Vent Free Room Heaters 15...

Страница 16: ...w Thermocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019...

Страница 17: ...ple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pul...

Страница 18: ...1 7 80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator...

Страница 19: ...1 7 80079 Gas Input Elbow Adapter 1 30 801 10 Fan Assembly 1 8 80083 Regulator 1 31 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 32 80019 Ignitor Pulse 1 10 80055 Regulator...

Страница 20: ...DERING INFORMATION PURCHASING Accessories may be purchased at any Mr Heater local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 800 251 0001 www mrheater co...

Отзывы: