F50S
Service Parts and Maintenance
MASTER PNEUMATIC - DETROIT, INC.
6701 -18 Mile Rd
. |
Sterling Heights, MI 48314 | Phone: (586) 254-1000 | Fax: (586) 254-6055 | Email: [email protected]
JAA 10-10-03
REV 10-03-05
(ECN 4075)
STU-2004
Installation Procedures
Replacement Parts & Kits
BF50S Section View
(Manual Drain)
KEY
DESCRIPTION
BF50S-2V
F50S-2V
1
Head
130-15S-1/4
130-15S-1/4
2
O-Ring, Bowl
406-23V
406-23V
3
Element Kit
KA130-27PE5V KA130-27PE5V
4
Metal Bowl with Manual Drain
ABF130-22SV
ABF130-22SV
5
Manual Drain Kit
K60F-11M
A130-19V
Not
Shown
Plastic Bowl with Manual Drain
A10F-130V
A10F-130V
THANK YOU!
You have just purchased a quality Filter from Master Pneumatic.
With care in it’s installation and maintenance, you can expect it to have a long and
economical service life. Before you go any further, please take a few
minutes to look over this information, then save it for future reference and
for the useful service information it contains.
1
2
3
INSTALLATION:
Depressurize and lockout air pressure. Install the filter as near as possible to the device it is to serve, following the arrow direction on the filter
head for air flow. Filters should be installed upstream of any regulators, lubricators, or valves in the air line.
ADJUSTMENTS:
Manual Drain:
For Metal Bowls: Turn knob (B) clockwise to drain filter. For Plastic bowls: Push drain knob to drain filter.
MAINTENANCE:
To clean or service the unit, depressurize and lockout air pressure. Remove bowl assembly by turning counterclockwise. To remove the element
(#3), insert a screwdriver in the slot located at the bottom of stem (A). Turn stem (A) counterclockwise until it is free of head (#1). Replace with
new element and reassemble to finger tight. Do not clean filter elements, they must be replaced. Sintered bronze elements may be cleaned by
soaking several hours in a suitable solvent, then blowing them out in reverse direction to normal flow with compressed air or steam. For manual
drain models, periodically drain to discharge accumulated liquids.
Plastic bowls may be cleaned with soap and water. Replace plastic bowls with metal if any signs of crazing or cracking are observed.
4
A
B
5
FLOW