22
7.5.2.
Generic 8 Port Remote Manifold Installation
A small 3” x 11” hole will need to be cut out of machine cabinet for proper installation of remote
manifold. A mounting bracket ships with remote manifold install kit for ease of installation.
1. Locate suitable location for remote manifold to be installed.
*Make sure location chosen for
remote manifold installation has proper clearance inside machine tooling cabinet for installation
of high pressure lines.
2. Once a suitable location is located, using supplied mounting bracket mark out the inside of
supplied bracket for hole outline (If no mounting bracket is included please refer to next page
for hole locations.)
3. Drill 4 pi
lot holes in each corner of 3” x11” rectangle. Holes must be large enough for small
jigsaw blade or sawzall blade to fit through.
4. Cut out rectangle starting in one of the four pilot holes.
5. Using supplied mounting bracket lineup center hole with hole in machine cabinet and mark the
6 screw holes on perimeter of mounting bracket.
6. Tap 6 holes for M6.
7. Using a high performance RTV Silicone Gasket maker or a comparable substance, make a
seal around perimeter of mounting bracket making sure to go around all screw holes to ensure
proper seal.
8. Mount remote manifold to machine cabinet with supplied M6 socket cap screws.
9.
Attach ¼” relief line to top of remote manifold run to ¼” dip tube in machine tool reservoir.
10.
Attach ½” high pressure feed line to outlet on V-2 Series.
11. Connect yellow control signal harness to yellow control signal harness on V-2 Series.