29
MPSYSTEMS-M-001/06
7.2.
Testing
Ensure all connections are secure and no hoses are rubbing.
Supply pump properly primed.
Prime valve has been closed.
Ensure motor rotation for all motors present in unit rotate clockwise.
Activate M-Codes and ensure corresponding port on unit activates.
Power off unit, machine tool should indicate an alarm.
o
Power unit back on, machine tool alarm should reset after 10 seconds.
7.3.
Start Up
Coolant/cutting fluid is pumped from the machine tool tank into the unit. The coolant/cutting fluid
enters the machine tank through (2) 5 micron #2 polyester filter bags. Filters utilized, use a
specialized rubber O-ring manufactured into filter bag, this allows for less debris to bypass filter bag
during normal operation.
Set maximum pressure before first use!
1. Turn main disconnect on unit to ‘OFF’ position;
2. Open wye valve(s) on top of unit;
3. Detach high pressure hose from unit;
Re-install caps supplied with machine.
4. Back out regulator (counter clockwise) on manifold all the way;
5. Turn main disconnect to ‘ON’ position;
6. Activate M-Code for high pressure;
7.
Slowly
rotate regulator (clockwise) until maximum pressure is achieved;
Maximum pressure listed above pressure gauge.
Typically 1000 psi.
8. Once maximum pressure has been reached, disengage M-Code;
9. Using lock nut behind regulator knob, lock in place, to avoid over pressurizing unit;
10. Turn main disconnect on unit to ‘OFF’ position;
11. Re-install high pressure hoses.
Warning:
Failure to follow these instructions can lead to pump failure and/or
void warranty.
Содержание AK CB20
Страница 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Страница 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Страница 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Страница 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Страница 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Страница 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Страница 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Страница 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Страница 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Страница 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Страница 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Страница 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...