background image

Section:
MOYNO

® 

500 PUMPS

Page:

1 of 4

Date:

March 1, 1998

SERVICE MANUAL

MOYNO

® 

500 PUMPS

300 Series Motorized

35650, 35651, 35652, 36750, 36751, and 36752 Model

DESIGN FEATURES

Housing:

Cast iron/316 SS

Pump Rotor:

 AISI 416 stainless steel/ANSI 316 SS

Pump Stator: 

NBR

Seal:

NBR (Nitrile)

Motor Shaft:

 Mechanical (carbon/ceramic)

Motor:

3 phase; 1-1/2 HP, 208/230/460V for Models
35650 and 35651; 2 HP, 230/460V for Models
36751 and 36750; 1 phase; 1-1/2 HP, 115/230V
for Model 35652; 1 phase; 2 HP, 115/230V for
Model 36752.60 Hertz, 1725 rpm, totally enclosed

Note:

Alternate elastomers available. Refer to Repair/ Conversion

Kit Numbers, page 4.

INSTALLATION

Mounting Position. Pump may be mounted in any
position. When mounting vertically, it is necessary to
keep bearings above seals to prevent possible seal
leakage into bearings.
Pre-Wetting. Prior to connecting pump, wet pump
elements and mechanical seal by adding fluid to be
pumped into suction and discharge ports. Turn pump
over several times in a clockwise direction to work
fluid into pump elements.
Piping. Piping to pump should be self-supporting to
avoid excessive strain on pump housings. See Table
1 for suction and discharge port sizes of each pump
model.
Use pipe “dope” or tape to facilitate disassembly and
to provide seal on pipe connections.
Electrical. Follow the wiring diagram on the motor
nameplate or inside the terminal box for the proper
connections. The wiring should be direct and conform
to local electrical codes. Check power connections for
proper voltage. Voltage variations must not
10% of nameplate voltage. Motors do not have
overload protection.
To prevent damage to pump, pump rotation must be
clockwise when facing pump from motor end.

OPERATION

Self-Priming. With wetted pumping elements, the
pump is capable of 25 ft. suction lift with pipe size
equal to port size. Be sure suction lines are air tight or
pump will not self-prime.
DO NOT RUN DRY. Unit depends on liquid pumped
for lubrication. For proper lubrication, flow rate should
be at least 10% of rated capacity.
Pressure and Temperature Limits. See Table 1 for
maximum discharge pressure of each model. Unit is
suitable for service at temperatures shown in Table 2.

Storage. Always drain pump for extended storage
periods by removing bottom drain plug. To drain
Model 36750, 36751 and 36752 remove suction
housing bolts and loosen suction housing.

Caution: Suction pressure should never be

greater than discharge pressure.

Table 1. Pump Data

Pump Model

356

367

Suction Port
(NPT)

1-1/2

2

Discharge Port
(NPT)

1-1/4

1-1/4

Voltage Rating
(VAC)

See Motor Name Plate

For Voltage Ratings

See Motor Name Plate

For Voltage Ratings

Discharge Pressure
(psig) (maximum)

50

50

NOTE:  SSU = 

5 x CP  

(approximate)

specific gravity

Table 2. Temperature Limits

Elastomer

Temperature Limits

*NBR

10°-160°F

*EPDM

10°-210°F

*FPM

10°-240°F

*NBR = Nitrile
EPDM = 

 

Ethylene-Propylene-Diene Terpolymer

FPM = Fluoroelastomer

Содержание 35650

Страница 1: ...te or inside the terminal box for the proper connections The wiring should be direct and conform to local electrical codes Check power connections for proper voltage Voltage variations must not exceed 10 of nameplate voltage Motors do not have overload protection To prevent damage to pump pump rotation must be clockwise when facing pump from motor end OPERATION Self Priming With wetted pumping ele...

Страница 2: ...g pump disconnect power source and thoroughly bleed pressure from system Failure to do so could result in electric shock or serious bodily harm 1 Disconnect power source 2 Remove suction and discharge piping 3 Remove screws 112 holding suction housing 2 to discharge housing 1 Remove suction housing 2 and stator 21 4 Rotor 22 can be detached from flexible joint 24 by using a punch to remove rotor p...

Страница 3: ...Page 3 ...

Страница 4: ...1 619 1550 161 1 2 13 x 1 112B Screw Hex Hd 2 req 320 6918 000 3 8 16 x 1 3 4 215 Lock Washer 623 0010 411 3 8 4 req 623 0010 411 3 8 6 req 215A Lock Washer 4 req 623 0010 411 3 8 623 0010 431 1 2 261 Pipe Plug 610 0120 011 1 8 NPT Recommended spare parts REPAIR CONVERSION KIT NUMBERS For cast iron pumps only Model 35651 Model 36751 Item No Description NBR EPDM FPM NBR EPDM FPM Kit No 311 9123 000...

Страница 5: ...period of time at no additional cost to you We appreciate your business and look forward to serving you in the future Always Insist on Genuine Moyno Replacement Parts Moyno Pump Warranty Registration Pump Model Pump Serial Purchased From Date Purchased Your Name Your Title Your Company Name Address City State Province Zip Code Phone Number Fax Number E mail Application for Which This Pump Was Purc...

Отзывы: