Moxa PRP/HSR Redundancy Box
User’s Manual
First Edition, March 2015
www.moxa.com/product
© 2015 Moxa Inc. All rights reserved.
Страница 1: ...Moxa PRP HSR Redundancy Box User s Manual First Edition March 2015 www moxa com product 2015 Moxa Inc All rights reserved ...
Страница 2: ...anges to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are peri...
Страница 3: ... 16 Port 3 16 Port Settings 3 16 Port Status 3 17 Redundant Protocol 3 17 Multicast Filtering 3 18 Security 3 19 Login Authentication 3 19 Management Interface 3 20 Trusted Access 3 21 Authentication Certificate 3 22 SNMP 3 22 SNMP Read Write Settings 3 23 Trap Settings 3 24 Diagnostics 3 25 LLDP 3 25 Ping 3 26 Port Mirror 3 26 Monitoring 3 27 CPU Memory Utilization 3 27 Statistics 3 29 Fiber Chec...
Страница 4: ... Moxa PRP HSR RedBox There are three ways to access the Moxa PRP HSR RedBox s configuration settings the USB console command line interface and web based interface Chapter 3 Featured Functions This chapter explains how to access the Moxa PRP HSR RedBox s various configuration monitoring and administration functions These functions can be accessed by serial Telnet command line or web based interfac...
Страница 5: ...sed interface If you do not know the Moxa PRP HSR RedBox s IP address you can open the USB console by connecting the Moxa PRP HSR RedBox to a PC s USB port with a USB cable You can open the Telnet or web based console over an Ethernet LAN or over the Internet The following topics are covered in this chapter USB Console Configuration 115200 None 8 1 VT100 Configuration by Command Line Interface CLI...
Страница 6: ...sing PComm Terminal Emulator when opening the USB console This software can be downloaded free of charge from the Moxa website Before running PComm Terminal Emulator install the USB console driver on your PC and then connect the Moxa PRP HSR RedBox s USB console port to your PC s COM port generally COM1 or COM2 depending on how your system is set up with USB to DB9 F or RJ45 to DB25 F cable After ...
Страница 7: ... HSR RedBox s Telnet or web console over a network requires that the PC host and Moxa PRP HSR RedBox are on the same logical subnet You may need to adjust your PC host s IP address and subnet mask By default the Moxa PRP HSR RedBox s IP address is 192 168 127 253 and the Moxa PRP HSR RedBox s subnet mask is 255 255 255 0 referred to as a Class B network Your PC s IP address must be set to 192 168 ...
Страница 8: ... cable NOTE The Moxa PRP HSR RedBox s default IP address is 192 168 127 253 After making sure that the Moxa PRP HSR RedBox is connected to the same LAN and logical subnet as your PC open the Moxa PRP HSR RedBox s Telnet console as follows 1 Click Start Run from the Windows Start menu and then Telnet to the Moxa PRP HSR RedBox s IP address from the Windows Run window You may also issue the Telnet c...
Страница 9: ...ure your PC host is on the management VLAN NOTE When connecting to the Moxa PRP HSR RedBox s Telnet or web console first connect one of the Moxa PRP HSR RedBox s Ethernet ports to your Ethernet LAN or directly to your PC s Ethernet port You may use either a straight through or cross over Ethernet cable NOTE The Moxa PRP HSR RedBox s default IP address is 192 168 127 253 After making sure that the ...
Страница 10: ...dBox is moxa Be sure to change the default password after your first log in to maintain a higher level of security 3 After logging in you may need to wait a few moments for the web console to appear Use the folders in the left navigation panel to navigate between different pages of configuration options ...
Страница 11: ...HSR RedBox In this chapter we use the web console interface to introduce the functions There are only a few differences between the web console USB console and Telnet console The following topics are covered in this chapter Home System Settings System Information User Account Network Date and Time Warning Notification MAC Address Table System Files Restart Factory Default VLAN Virtual LAN VLAN Fil...
Страница 12: ... administrators to maintain and control a Moxa PRP HSR RedBox System Information Configure the following System Information to make it easier to identify different PRP HSR RedBoxes connected to your network Device Name Setting Description Factory Default Max 30 characters This option is useful for differentiating between the roles or applications of different units Example Factory PRP HSR RedBox 1...
Страница 13: ...ls of configuration access admin and user Accounts with admin authority have read write access to all configuration parameters whereas accounts with user authority only have read access to configuration parameters NOTE 1 In order to maintain a higher level of security be sure to change the default password after your first log in 2 The user with admin account name cannot be deleted or disabled Act...
Страница 14: ...actory Default User Name Max of 30 characters User Name None Password Password for the user account Minimum requirement is 4 characters maximum of 16 characters None Modifying an Existing Account Select the existing account from the Account List table Modify the details accordingly and then apply the settings to save the configuration Deleting an Existing Account Select the existing account from t...
Страница 15: ...ents the PRP HSR RedBox must be configured with a Global Unicast address Get IP From Setting Description Factory Default DHCP The Moxa PRP HSR RedBox s IP address will be assigned automatically by the network s DHCP server DHCP BOOTP The Moxa PRP HSR RedBox s IP address will be assigned automatically by the network s BootP server Manual The Moxa PRP HSR RedBox s IP address must be set manually IP ...
Страница 16: ...dress The network portion of the Global Unicast address can be configured by specifying the Global Unicast Prefix and using an EUI 64 interface ID in the low order 64 bits The host portion of the Global Unicast address is automatically generated using the modified EUI 64 form of the interface identifier PRP HSR RedBox s MAC address None IPv6 Link Local Address Setting Description Factory Default N...
Страница 17: ...ock source from SNTP Time Zone Setting Description Factory Default Time zone Specifies the time zone which is used to determine the local time offset from GMT Greenwich Mean Time GMT Greenwich Mean Time Daylight Saving Time The Daylight Saving Time settings are used to automatically set the Moxa PRP HSR RedBox s time adjustments according to national standards Start Date Setting Description Factor...
Страница 18: ...s Disabled Warning Notification Since industrial Ethernet devices are often located at the endpoints of a system these devices will not always know what is happening elsewhere on the network This means that an PRP HSR RedBox that connects to these devices must provide system maintainers with real time alarm messages Even when control engineers are out of the control room for an extended period of ...
Страница 19: ...ogged in to the system Auth Fail An incorrect password was entered Auth Attempts Over Limit More than 3 Auth Attempts were tried Password Change User changed the account password DI1 On Off Digital Input 1 was triggered by an on to off transition DI1 Off On Digital Input 1 was triggered by an off to on transition ABC 02 Status Occurs when an ABC 02 USB T was connected to or disconnected from the P...
Страница 20: ...The PT G503 PHR PTP series will send notification to the trap server when an event is triggered E Mail The PT G503 PHR PTP series will send notification to the email server defined in the Email Settings Syslog The PT G503 PHR PTP series will record a syslog to syslog server defined in Syslog Server Settings Relay The PT G503 PHR PTP series supports digital inputs to integrate sensors When an event...
Страница 21: ...ver that supports the CRAM MD5 LOGIN and PAIN methods of SASL Simple Authentication and Security Layer authentication mechanism We strongly recommend not entering your Account Name and Account Password if auto warning email messages can be delivered without using an authentication mechanism Syslog Server Settings The Syslog function provides the event logs for the syslog server The function suppor...
Страница 22: ...button The event will still be recorded in the event list MAC Address Table The MAC address table shows the MAC address list passed through the Moxa PRP HSR RedBox The MAC Address table can be configured to display the following Moxa PRP HSR RedBox MAC address groups which are selected from the drop down list Drop Down List ALL Select this item to show all of the Moxa PRP HSR RedBox s MAC addresse...
Страница 23: ...TFTP Server and Auto Backup Configurator ABC 02 Local 1 Download the updated firmware rom file from Moxa s website www moxa com 2 Browse for the rom file and then press the Upgrade button TFTP Server 1 Enter the TFTP Serve IP 2 Input the firmware file name rom and press the Upgrade button Auto Backup Configurator ABC 02 1 Download the updated firmware rom file from Moxa s website www moxa com 2 Sa...
Страница 24: ...C ini The purpose of saving to two files is to identify the file while using Auto load configuration from ABC to system when boot up Note MAC ini is named using the last 6 digits of the PRP HSR RedBox s MAC address without spaces 2 Click Browse to select the configuration file and then click Restore to start loading the file into your PRP HSR RedBox 3 Auto load configuration from ABC 02 to system ...
Страница 25: ... to the ABC 02 Simply press the Reset button on top of the RedBox to force the RedBox to start backing up the current system configuration files and event logs to the ABC 02 NOTE DO NOT remove the ABC 02 while performing upgrade backup or restore functions Restart This function provides users with a quick way of restarting the system Factory Default This function provides users with a quick way of...
Страница 26: ...filtering function Disable VLAN Setting Description Factory Default VLAN ID ranges from 1 to 4094 Set the VLAN IDs using commas to differentiate different VIDs that will be filtered by the interlink port this product supports up to 256 VLAN groups None Port Port Settings Port settings are included to give the user control over port access port transmission speed flow control and port type MDI or M...
Страница 27: ...wing table shows the status of each port including media type link status flow control and port state Redundant Protocol The Moxa PRP HSR RedBox supports four redundant protocols PRP HSR Coupling and QuadBox Depending on the topology of your network you can choose one of these redundancy protocols All four protocols support a 0 ms recovery time PRP Copies of each packet are sent from the source to...
Страница 28: ... or forward ingress traffic that comes from the designated port with a specific multicast MAC address Action Setting Description Factory Default Drop Forward The RedBox will drop or forward traffic depending on the setting Drop Priority Index Setting Description Factory Default 1 to 8 Items with priority 1 will be acted on first followed by items with priority 2 etc 1 Source Port Setting Descripti...
Страница 29: ... Authorization and Accounting systems for connecting to network services The fundamental purpose of both TACACS and RADIUS is to provide an efficient and secure mechanism for user account management Setting Description Factory Default Authentication Protocol Authentication protocol selection TACACS Server IP Name Set the IP address of an external TACACS RADIUS server as the authentication database...
Страница 30: ... Select Deselect Checkmark the appropriate check boxes to enable SSL Select Port 443 Enable Telnet Setting Description Factory Default Select Deselect Checkmark the appropriate check boxes to enable Telnet Select Port 23 Enable SSH Setting Description Factory Default Select Deselect Checkmark the appropriate check boxes to enable SSH Select Port 5 Web Auto Logout min Setting Description Factory De...
Страница 31: ...cess to 192 168 1 1 only Grant access to any host on a specific subnetwork For example enter IP address 192 168 1 0 with netmask 255 255 255 0 to allow access to all IPs on the subnet defined by this IP address subnet mask combination Grant access to all hosts Make sure the accessible IP list is not enabled Remove the checkmark from Enable the accessible IP list The following table shows additiona...
Страница 32: ...g table Select the security mode and level that will be used to communicate between the SNMP agent and manager Protocol Version UI Setting Authentication Encryption Method SNMP V1 V2c V1 V2c Read Community Community string No Uses a community string match for authentication V1 V2c Write Read Community Community string No Uses a community string match for authentication SNMP V3 No Auth No No Uses a...
Страница 33: ...string to authenticate the SNMP agent for read write access The SNMP server will access all objects with read write permissions using this community string Private For SNMP V3 two levels of privilege are available to access the Moxa PRP HSR RedBox Admin privilege provides access and authorization to read and write the MIB file User privilege allows reading of the MIB file only Admin Auth Type for ...
Страница 34: ...g the specified data encryption key between 8 and 30 characters No Disable No data encryption No Trap Settings SNMP traps allow an SNMP agent to notify the NMS of a significant event The PRP HSR RedBox supports two SNMP modes Trap mode and Inform mode SNMP Trap Mode Trap In Trap mode the SNMP agent sends an SNMPv1 trap PDU to the NMS No acknowledgment is sent back from the NMS so the agent has no ...
Страница 35: ...P Overview LLDP is an OSI Layer 2 protocol defined by IEEE 802 11AB LLDP standardizes the self identification advertisement method and allows each networking device such as a Moxa managed PRP HSR RedBox to periodically send its system and configuration information to its neighbors Because of this all LLDP devices are kept informed of each other s status and configuration and with SNMP this informa...
Страница 36: ... Ping The Ping function uses the ping command to give users a simple but powerful tool for troubleshooting network problems The function s most unique feature is that even though the ping command is entered from the user s PC keyboard the actual ping command originates from the Moxa PRP HSR RedBox itself In this way the user can essentially sit on top of the Moxa PRP HSR RedBox and send ping comma...
Страница 37: ...e from the Moxa PRP HSR RedBox s DSL extender s web console and USB console CPU Memory Utilization The CPU Memory Utilization page displays how much system resources are being utilized Monitor this information to get a quick snapshot of the PRP HSR RedBox s current status CPU Utilization Setting Description Factory Default Read only CPU usage volume in the past 5 seconds 30 seconds or 5 minutes Pa...
Страница 38: ...PRP HSR Redundancy Box Featured Functions 3 28 ...
Страница 39: ... sent out from the Moxa PRP HSR RedBox RX Packets are packets received from connected devices and Error Packets are packets that did not pass TCP IP s error checking algorithm The Total Packets option displays a graph that combines TX RX and TX Error RX Error Packet activity The graph displays data transmission activity by showing Packets s i e packets per second or pps versus sec seconds In fact ...
Страница 40: ...display of the individual port activity that can be viewed with the Console Monitor function discussed above The All Ports option shows three vertical bars for each port The height of the bar represents Packets s for the type of packet at the instant the bar is being viewed That is as time progresses the height of the bar moves up or down so that the user can view the change in the rate of packet ...
Страница 41: ...the central site This function makes it much easier to troubleshoot optical fiber links and virtually eliminates the cost of onsite debugging at remote sites Parameter Description Port No PRP HSR RedBox port number with SFP plugged in Model Name Moxa SFP model name Temperature C SFP casing temperature Voltage V Voltage supplied to the SFP Tx power dBm The amount of light being transmitted into the...
Страница 42: ...nt date is set on the Basic Settings page Time The time is updated based on how the current time is set on the Basic Settings page System Startup Time The system startup time related to this event Event Events that have occurred NOTE The following events will be recorded into the Moxa PRP HSR RedBox s Event Log Table Cold start Warm start Configuration change activated Power 1 2 transition Off On ...
Страница 43: ...PRP HSR Redundancy Box Featured Functions 3 33 System Services This page shows the services summary running on the RedBox device ...
Страница 44: ...up ifTable MIB II 4 IP Group ipAddrTable ipNetToMediaTable IpGroup IpBasicStatsGroup IpStatsGroup MIB II 5 ICMP Group IcmpGroup IcmpInputStatus IcmpOutputStats MIB II 6 TCP Group tcpConnTable TcpGroup TcpStats MIB II 7 UDP Group udpTable UdpStats MIB II 10 Transmission Group dot3 dot3StatsTable MIB II 11 SNMP Group SnmpBasicGroup SnmpInputStats SnmpOutputStats The Moxa PRP HSR RedBox also provides...
Страница 45: ...PRP HSR Redundancy Box MIB Groups A 2 Public Traps Cold Start Warm Start Link Up Link Down Authentication Failure Fiber Check Private Traps Configuration Changed Power On Power Off LLDPChgTrap ...
Страница 46: ...ear logging clear System event logs clear counters Clear statistics counters Show Commands Command Display Information show version System version information show system System hardware and software status show interfaces hw_interface Display hardware interface configuration show clock Display the system clock show redundancy PRP HSR Display redundancy protocol status show redundancy mode Current...
Страница 47: ...R Specify the redundancy protocol multicast filter action drop forward Set multicast filter action multicast filter UINT index Enable Multicast filter priority entry multicast filter addr UINT index MACADDR MacAddress set multicast filter address multicast filter src port UINT index UINT port Set source port of the multicast priority entry multicast filter mac compare length UINT index UINT len Se...