Wiring the Power Input 

Top and front views of the terminal block connector are shown below: 

 

STEP 1:

 Insert the negative/positive DC wires 

into the V-/V+ terminals, and the ground wire 
into the GND terminal. 
 

STEP 2:

 To keep the DC wires from pulling 

loose, use a small flat-blade screwdriver to 
tighten the wire-clamp screws on the front of 
the terminal block connector. 
 

STEP 3:

 Insert the plastic terminal block 

connector prongs into the terminal block 
receptor, which is located on the bottom panel 
of the OnCell 3120-LTE-1. 

 

 

 

ATTENTION 

Before connecting the OnCell 3120-LTE-1 to the DC power 
inputs, make sure that the DC power source voltage is stable. 

 

Communication Connections 

10/100Base-T(X) Ethernet Port Connection 

The 10/100Base-T(X) ports located on the front panel of the OnCell 
3120-LTE-1 are used to connect to Ethernet-enabled devices. 
Pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) 
ports are shown below: 

MDI Port Pinouts 

MDI-X Port Pinouts 

8-pin RJ45 

Pin 

Signal 

Pin 

Signal 

 

Tx+ 

Rx+ 

Tx- 

Rx- 

Rx+ 

Tx+ 

Rx- 

Tx- 

Serial DB9 Connection 

The OnCell 3120-LTE-1 has one DB9 male port that supports RS-232, 
RS-485-4W, RS-485-2W, and RS-422. The pin assignments are shown 
in the table below: 
 
 
 
 
 
 

Содержание OnCell 3120-LTE-1

Страница 1: ...port Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 0...

Страница 2: ...y The OnCell 3120 LTE 1 also comes with a 3 in 1 serial port for serial over LTE cellular network communication making it suitable for collecting and exchanging data with serial Ethernet devices Packa...

Страница 3: ...3120 LTE 1 to a computer See the 10 100BaseT X Ethernet Port Connection section below for detailed instructions If the LAN LED indicator on the OnCell 3120 LTE 1 lights up it means a connection has b...

Страница 4: ...ular antenna port 3 10 100 Base T X Ethernet port 1 RJ45 4 10 100 Base T X Ethernet port 2 RJ45 5 USB port 6 DB9 serial port 7 LED display 8 Reset button 9 Console port reserved for engineering use 10...

Страница 5: ...he back panel Mount the OnCell 3120 LTE 1 Series on corrosion free mounting rails that meet the EN 60715 standard Installation STEP 1 Insert the upper lip of the DIN rail into the top hook of the DIN...

Страница 6: ...OnCell 3120 LTE 1 device with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should b...

Страница 7: ...y First Be sure to disconnect the power cord before installing and or wiring the OnCell 3120 LTE 1 device Read and Follow These Guidelines Use separate paths to route wiring for power and devices If p...

Страница 8: ...e zero If the potential difference is NOT zero the product could be permanently damaged SIM Card Socket The OnCell 3120 LTE 1 comes with two nano SIM card sockets for cellular communication The nano S...

Страница 9: ...e OnCell 3120 LTE 1 ATTENTION Before connecting the OnCell 3120 LTE 1 to the DC power inputs make sure that the DC power source voltage is stable Communication Connections 10 100Base T X Ethernet Port...

Страница 10: ...3120 LTE 1 The function of each LED is described in the table below LED Color Behavior Function SYS 2 LEDs Green Power On System startup is complete and the system is in operation Off No power is sup...

Страница 11: ...r signal strength Specifications Input Current 0 8 A max Input Voltage 9 to 36 VDC Power Consumption 5 W typ Operating Temperature Standard Models 0 to 55 C 32 to 131 F Wide Temp Models 30 to 70 C 22...

Страница 12: ...NFPA 70 National Electrical Code Article 810 and Canada Canadian Electrical Code Section 54 ATTENTION For EXPLOSION PROOF applications the OnCell 3120 LTE 1 is designed and certified to meet ATEX and...

Страница 13: ...2 I SH 01 2013 11 I SH 02 2014 10 IEC 60079 15 4th Edition 2010 01 I SH 01 2016 09 5 Conditions for Safe Usage These devices shall be mounted in a suitable tool accessible ATEX IECEx certified enclosu...

Отзывы: