Moxa Technologies ioThinx 4500 45ML-5401 Скачать руководство пользователя страница 7

ioThinx 4500 (45ML) Module Series 

Preface 

 

1-3 

 

WARNING 

Devices discussed in this document are sensitive to electrostatic discharge, which can cause internal damage 
to and/or affect normal operation of the devices. Observe the following precautions when handling a device: 

 

Before touching the device, touch a grounded object with your finger to discharge static electricity. 

 

Wear an approved grounding wristband. 

 

Do not touch connectors or pins on component boards. 

 

Do not touch circuit components inside the equipment. 

 

Use a static-safe workstation, if available. 

 

Store the device in appropriate static-safe packaging when not in use. 

 

 

 

WARNING 

Check the voltage supplied by the power source. Make sure the voltage provided by the power source matches 
the voltage required by the device. 

 

 

 

WARNING 

Check the voltage or current of the sensors or loads. Make sure the voltage and/or current indicated on the 
sensors or loads corresponds to the specifications of your 45ML module before you connect the device. 

 

 

 

WARNING 

Connect your device to an earthed ground. 

 

 

 

CAUTION 

Do not use the device if the device itself is already damaged. Replace defective or damaged devices to ensure 
that your devices function properly. 

 

 

 

CAUTION 

Do not attempt to repair the device yourself. If your device needs to be repaired, return the device to Moxa’s 
customer service department. Attempting to repair the device yourself could invalidate the device’s warranty. 

 

Additional Resources 

Refer to following documents for additional information. 

 

Datasheets for the following products: 

 

ioThinx 4530 Series 

 

ioThinx 4500 Series (45ML) Modules 

 

User’s Manuals: 

 

ioThinx 4530 Series Hardware User’s Manual 

 

ioThinx 4530 Series Linux User’s Manual 

 

Programming Guide: 

 

ioThinx 4530 Series Programming Guide 

 

Содержание ioThinx 4500 45ML-5401

Страница 1: ...ioThinx 4500 45ML Module Series User s Manual Version 1 0 July 2020 www moxa com product 2020 Moxa Inc All rights reserved ...

Страница 2: ...changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are pe...

Страница 3: ...oderate risk potentially hazardous situation which may result in moderate to serious injury CAUTION Indicates a low risk potentially hazardous situation which may result in minor or moderate injury NOTE Indicates a potential malfunction which will not result in damage to property INFORMATION This information is important for preventing errors ...

Страница 4: ...1 3 2 Product Overview 2 1 Technical Data 2 2 Common Specifications 2 2 45ML 5401 Specifications 2 2 Appearance 2 3 Front View 2 3 Dimensions 2 3 LED Indicators 2 4 3 Hardware Installation 3 1 Module Specifications 3 2 Terminal Blocks 3 2 45ML 5401 3 2 Mounting the Module 3 4 Installing the Module on the DIN Rail 3 4 Unmounting the I O Module from the DIN Rail 3 5 ...

Страница 5: ...chapter we explain the scope of and how to use this document The following topics are covered in this chapter Revision History Relevant Models Package Contents How to Use This Device Safety Precautions Additional Resources ...

Страница 6: ...00 Series User s Manual for details NOTE Be sure to connect both the system and field power on the ioThinx 4530 series to the power supply otherwise the 45ML module may not work properly Safety Precautions Observe the following safety precautions when installing or using the devices discussed in this document DANGER Never work on the device while the power source is switched on Disconnect all powe...

Страница 7: ...ice WARNING Check the voltage or current of the sensors or loads Make sure the voltage and or current indicated on the sensors or loads corresponds to the specifications of your 45ML module before you connect the device WARNING Connect your device to an earthed ground CAUTION Do not use the device if the device itself is already damaged Replace defective or damaged devices to ensure that your devi...

Страница 8: ...In this chapter we give an overview of each of the 45ML modules The following topics are covered in this chapter Technical Data Common Specifications 45ML 5401 Specifications Appearance Front View Dimensions LED Indicators ...

Страница 9: ... Models 40 to 75 C 40 to 167 F 45ML 5401 Specifications Serial Communication Interface 4 RS 232 422 485 ports software selectable Isolation 3k VDC or 2k Vrms Serial Communication Parameters Parity None Even Odd Data Bits 7 8 Stop Bits 1 2 Flow Control RTS CTS RS 232 only XON XOFF Pull High Low Resistor for RS 485 10 kilo ohm Baudrate 300 600 1200 1800 2400 4800 9600 19200 38400 57600 115200 bps Se...

Страница 10: ...ioThinx 4500 45ML Module Series Product Overview 2 3 Appearance Front View Dimensions Unit mm inch ...

Страница 11: ...iption Status Status 1 Green Steady on Module ready Slow Blinking Booting up Red Steady on Module error Slow Blinking Upgrading firmware Off Power off Port 1 Port 2 Port 3 Port 4 Serial connection 2 of each Green Transmitting data Tx Amber Receiving data Rx off Disconnected or data is not being transmitted ...

Страница 12: ... we describe how to install the 45ML modules The following topics are covered in this chapter Module Specifications Terminal Blocks 45ML 5401 Mounting the Module Installing the Module on the DIN Rail Unmounting the I O Module from the DIN Rail ...

Страница 13: ...t 2 6 TxD2 TxD2 Data2 Port 4 16 TxD4 TxD4 Data4 7 RxD2 TxD2 Data2 17 RxD4 TxD4 Data4 8 RTS2 RxD2 18 RTS4 RxD4 9 CTS2 RxD2 19 CTS4 RxD4 10 GND GND GND 20 GND GND GND Setting Up Termination Resistors When setting up your RS 485 and RS 422 networks for long distance communication you should use termination resistors to prevent signal reflections The following figures illustrate how to properly config...

Страница 14: ...ioThinx 4500 45ML Module Series Hardware Installation 3 3 Setting Up Terminators for a 2 wire RS 485 Network Setting Up Terminators for an RS 422 Network ...

Страница 15: ...ule on the DIN Rail Step 1 Align the I O module side by side with the head CPU module making sure that the upper and lower rails are hooked together Step 2 After aligning the I O module side by side with the network module push the I O module until it touches the DIN rail Next apply more force until the module clips to the DIN rail NOTE After the module is firmly attached to the DIN rail the modul...

Страница 16: ...he module Step 2 Push the top of the release tab to latch it and then pull the module out NOTE Electrical connections for the internal bus will be disconnected when the module is removed NOTE The 45MR module can be installed on the right side of every ioThinx 4500 Series head CPU module whereas 45ML modules only can only be used with ioThinx 4500 series devices that have a communication bus on the...

Отзывы: