EDS-518A Series User’s Manual
Featured Functions
3-14
Configuring SNMP
EDS-518A supports SNMP V1/V2c/V3. SNMP V1, and SNMP V2c use a community string
match for authentication, which means that SNMP servers access all objects with read-only or
read/write permissions using the community string
public/private
(default value). SNMP V3,
which requires you to select an authentication level of MD5 or SHA, is the most secure protocol.
You can also enable data encryption to enhance data security.
SNMP security modes and security levels supported by EDS-518A are shown in the following
table. Select the security mode and level that will be used to communicate between the SNMP
agent and manager.
Protocol
Version
UI Setting
Authentication
Type
Data
Encryption
Method
V1, V2c
Read
Community
Community
string
No
Use a community string match
for authentication
SNMP V1,
V2c
V1, V2c
Write/Read
Community
Community
string
No
Use a community string match
for authentication
No-Auth No
No
Use account with admin or user
to access objects
MD5 or SHA
Authentication
based on MD5
or SHA
No
Provides authentication based on
HMAC-MD5, or HMAC-SHA
algorithms. 8-character
passwords are the minimum
requirement for authentication.
SNMP V3
MD5 or SHA
Authentication
based on MD5
or SHA
Data encryption
key
Provides authentication based on
HMAC-MD5 or HMAC-SHA
algorithms, and data encryption
key. 8-character passwords and a
data encryption key are the
minimum requirements for
authentication and encryption.
These parameters are configured on the SNMP page. A more detailed explanation of each
parameter follows.
SNMP Read/Write Settings
SNMP Versions
Setting
Description
Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
Select the SNMP protocol version used to
manage the switch.
V1, V2c
V1, V2c Read Community
Setting
Description
Factory Default
V1, V2c Read
Community
Use a community string match with a
maximum of 30 characters for
authentication. The SNMP agent accesses
all objects with read-only permissions
using the community string
public
.