Date and Time
The Moxa switch has a time calibration function based on information from an NTP server or user specified
time and date, allowing functions such as automatic warning emails to include a time and date stamp.
NOTE
The user must update the Current Time and Current Date after powering off the switch for a long period of
time (for example a few days). The user must pay particular attention to this when there is no NTP server,
LAN, or Internet connection.
System Up Time
Indicates how long the Moxa switch has been up and running since the last cold start.
Current Time
Setting
Description
Factory Default
User-specified time
Indicates time in yyyy-mm-dd format.
None
Time Zone
Setting
Description
Factory Default
Time zone
Specifies the time zone, which is used to determine the local
time offset from GMT (Greenwich Mean Time).
GMT (Greenwich
Mean Time)
Daylight Saving Time
The Daylight Saving Time settings are used to automatically set the Moxa switch’s time ahead according to
national standards.
Start Date
Setting
Description
Factory Default
User-specified date
Specifies the date that Daylight Saving Time begins.
None
End Date
Setting
Description
Factory Default
User-specified date
Specifies the date that Daylight Saving Time ends.
None
Offset
Setting
Description
Factory Default
User-specified hour
Specifies the number of hours that the time should be set
forward during Daylight Saving Time.
None
Clock Source
Setting
Description
Factory Default
Local
Configure clock source from local time
Local
NTP
Configure clock source from NTP
SNTP
Configure clock source from SNTP