CN2510
Getting Started
2-14
3.
The
Lan
page contains input/display fields for
DHCP (client
),
Async server IP address
,
Async server
IP netmask
,
Default gateway IP address
,
Ethernet speed
, and
Ethernet address
. Each item is
described in detail below.
CN2510-8
CN2510-8_5631 V2.0
------------------------------------------------------------------------------
Info.
[Lan]
Adv. Host_table Route_table User_table Quit
Examine/modify the Ethernet LAN port setting
ESC: back to menu Enter: select
Ethernet LAN port 1:
DHCP (client)
[Disable]
Async server IP address
[192.168.127.254]
Async server IP netmask
[255.255.255.0 ]
Default gateway IP address
[
]
Ethernet speed
[ ---- ]
Ethernet address
[00:90:E8:26:10:09]
DHCP (client)
—
When DHCP is enabled, CN2510 will request an available IP address and Netmask over the
network from the DHCP Server. If an IP address is not available, CN2510 will use the current IP address, but
will continue sending requests to the DHCP Server.
Async server IP address
—
This field MUST contain an IP address unique to the network. The IP address
is written using the notation “ddd.ddd.ddd.ddd,” in which each “ddd” is a nonnegative decimal number
strictly less than 256 (i.e., an 8-bit integer). The default value is 192.168.127.254.
Async server IP netmask
—
A netmask is used to group network hosts into subnets. CN2510 sends TCP/IP
packets directly to hosts that are on the same subnet. If the recipient of the packet is NOT on the same
subnet, the packet is sent to the default gateway IP address.
Default gateway IP address
—
This field contains the IP address of a router on the local network. The
default gateway is used when a packet is sent to an IP address that is not on the subnet specified in
CN2510’s local routing table.
Ethernet speed
—
If the Ethernet port is active, the Ethernet speed will be set automatically to 10BaseT or
100BaseT. This field cannot be modified.
Ethernet address
—
This field contains the hardware Ethernet address. This field cannot be modified.
Server Configuration—Adv.
1.
From the
MAIN MENU
, use the arrow keys to select
Server
, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
MAIN MENU
------------------------------------------------------------------------------
[Server]
Port seTting sAve Utility Restart Exit
Examine/modify async server node/table configuration
Enter: select ESC: previous menu
2.
From the
SERVER MENU
, select
Adv.
, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
SERVER MENU
------------------------------------------------------------------------------
Info. Lan
[Adv.]
Host_table Route_table User_table Quit
Examine/modify async server basic configuration
Enter: select ESC: previous menu
Содержание CN2510-16
Страница 17: ...CN2510 Getting Started 2 9 5 Click on Next to continue 6 Wait while the PComm Lite software is installed...
Страница 219: ...CN2510 RADIUS Server B 9 5 Select TCP IP protocol and then click on Next to continue 6 Specify an IP address...
Страница 220: ...CN2510 RADIUS Server B 10 7 Select Yes I want to use a RADIUS server and then click on Next to start using this function...