AirWorks AWK-3131A
Web Console Configuration
3-64
The SNMP MIB file is also available from SNMP MIB File EXPORT.
To download the configuration to the AWK:
1.
Turn off the AWK.
2.
Plug in the ABC-01 to the AWK’s RS-232 console.
3.
Turn on AWK.
4.
AWK will detect the ABC-01 during the boot up process, and download the configuration from the ABC-
01 to the AWK automatically. Once the configuration downloads correctly, the AWK emits three short
beeps and then continues with the boot-up process.
5.
Once the AWK has booted up successfully, it will emit the normal two beeps, and the ready LED will turn
to solid green.
Load Factory Default
Use this function to reset the AWK-3131A and roll all settings back to the factory default values. You can
also reset the hardware by pressing the reset button on the top panel of the AWK-3131A.
Account Settings
To ensure that devices located at remote sites are secure from hackers, we recommend setting up a high-
strength password the first time you configure the device.