AWK-3131A-M12-RCC
Web Console Configuration
3-46
If the node and access path are available, you will see that all packets were successfully transmitted with no
loss. Otherwise, some, or even all, packets may get lost, as shown in the following figure.
Firmware Upgrade
The AWK-3131A-M12-RCC can be enhanced with more value-added functions by installing firmware upgrades.
The latest firmware is available at Moxa’s download center.
Before running a firmware upgrade, make sure the AWK-3131A-M12-RCC is off-line. Click the Browse button
to specify the firmware image file and click Firmware Upgrade and Restart to start the firmware upgrade.
After the progress bar reaches 100%, the AWK-3131A-M12-RCC will reboot itself.
When upgrading your firmware, the AWK-3131A-M12-RCC’s other functions are forbidden.
Config Import Export
You can back up or restore the AWK-3131A-M12-RCC’s configuration with Config Import Export.
In the Config Import section, click Browse to specify the configuration file and click Config Import button
to begin importing the configuration.
You can also back up or restore the ABC-01 (HW Rev. 1.1 support only) configuration with Config Import
Export.
ATTENTION
Please make sure the power source is stable when you upgrade your firmware. An unexpected power breakup
may damage your AWK-3131A-M12-RCC.