![Moxa Technologies AIG-500 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/moxa-technologies/aig-500-series/aig-500-series_hardware-user-manual_1841905009.webp)
AIG-500 Series HW UM
Hardware Introduction
2-4
Reset to Default
Refer to ThingsPro Edge user manual to execute Reset to Default function. No hardware button is available
for resetting the device to factory default.
Real-time Clock
The real-time clock is powered by a non-chargeable battery. We strongly recommend that you do not
replace the lithium battery without help from a qualified Moxa support engineer. If you need to change the
battery, contact the Moxa RMA service team.
WARNING
There is a risk of explosion if the battery is replaced with an incorrect type.
Installation Options
DIN-rail Mounting (optional)
The optional DIN-rail mounting kit is not included in the product package and must be purchased
separately.
Follow these steps to mount the device on to a DIN rail:
Installation
STEP 1:
Use 4 screws to attach the DIN-rail mounting
bracket to the AIG-500’s rear panel and tighten the
screws to secure the bracket.
STEP 2:
Insert the upper lip of the DIN rail into the DIN-rail
mounting kit.
STEP 3:
Press the AIG-500 towards the DIN rail until it
snaps into place.