42
Instruction manual - EN
43
8. SHM Triaxial Accelerometer
Accelerometer components
Number of pieces
Accelerometer sensor
1 pz.
LoRaWAN 868 Mhz Antenna
1 pz.
Countersunk screws M6
2 pz.
Installation plate
1 pz.
Screws TCEI M6
2 pz.
Washers M6
2 pz.
Brass anchors for concrete
2 pz.
CE material
1 pz.
8.2
All devices manufactured by Move Solutions ™ are tested and fine-tuned by the ma-
nufacturer before shipping and delivery to the customer.
Make sure that the package contains the following components:
Check for any damage to the device. Check that the various parts of the device do not
show physical damage due to impacts, tears or abrasions.
In particular, check that there are no marks or dents that may indicate impacts oc-
curred during transportation and that the input and output ports are not damaged.
NOTE
•
The components included in the package may vary depending on the model or
version purchased. The components shown refer to the model of the DECKA-
XE-SHM monitoring device.
Unpacking Instructions Accelerometer
BATTERY CHANGE INSTRUCTIONS
To change the Accelerometer batteries, follow the steps below:
1.
Unscrew the sensor cover using a Phillips screwdriver.
2.
Gently open the cover, taking care not to break the connector that connects the
antenna on the cover to the electronic board.
3.
Remove the existing battery.
4.
Insert a new D 3.6V lithium battery paying attention to respect the polarity in-
dicated on the battery holder, it is recommended to contact Move Solutions ™
directly to supply batteries.
5.
Close the sensor cover making sure that the antenna connector does not get
squeezed between the cover and the body of the case.
NOT INTENDED USE OF THE ACCELEROMETER
No use other than those described in this manual is intended.
The device is not intended for any use other than those described in the chapter “Use
and safety guidelines” and “Intended Use of the Accelerometer”.
It is absolutely forbidden to make any changes to the Move Solutions™ monitoring
system. Any damage to people, animals or things deriving from the use of the device
modified improperly by an unauthorized operator, is not attributable to the manu-
facturer which is therefore relieved of all responsibility.
INTENDED USE OF THE ACCELEROMETER
For correct operation of the device, as described later in the chapter “Accelerometer
installation guide”, first of all the Accelerometer device must be firmly installed on a
wall, ceiling or floor of any structure, in specific and targeted points, according to the
supplier company instructions.
Each specific Accelerometer device must be oriented following the directions given
on the orientation label located on the cover, as described in the “Accelerometer In-
stallation Guide” chapter.
•
DO NOT use the device with batteries other than those supported and
indicated in the “Accelerometer Datasheet”.
•
DO NOT disassemble this product. Disassembling this product may
create anomalies in sensor measurements.