MOUNTAIN ALARM
DIV. OF J.D DAVIS COMPANY, INC.
1235 S. HURON STREET
DENVER, CO 80223
Congratulations on you new alarm detection system. The system is very simple to operate.
Mountain Alarm has tried to anticipate some of your questions. The following operating instructions will
help you familiarize yourself with the
XL 4600 System.
1.
4.
2.
5.
3.
6.
A. KEYPAD OPERATION
:
1. ZONE LIGHTS (ZONES 1-6):
Zone Normal ------------------------------------ Light Off
Zone Open -------------------------------------- Light On
Zone Bypassed -------------------------------- Slow Blink
Zone Alarm ------------------------------------- Fast Blink
2. STATUS LIGHTS:
RDY: -------------------------------------- ON- System Ready to be armed.
OFF- System not ready to be armed.
ARM: -------------------------------------- ON- System is armed.
OFF- System is off.
STAY: ------------------------------------ ON- Interior zones are bypassed.
OFF- Interior zones are normal.
INST.: ------------------------------------ ON- Entry doors are instant.
OFF- Entry doors are delay.
AC/LB: ----------------------------------- ON- AC power is present.
OFF- AC power is off.
NOTE:
1. A blinking “AC/LB” light & blinking keypad is a trouble signal and it
indicates low battery. To silence enter your code at the Keypad.
B. SYSTEM OPERATION:
1. ARMING THE SYSTEM (Leaving Home): 1. Enter your four digit code.
2. Press “#” & 1 to quick arm OR
3. Press “#” & “2” to force arm.
NOTE: 1. There is a time delay on the entry/exit doors.
2. You must leave within 60 seconds.
2. ARMING THE SYSTEM (Staying Home):--1. Press the “STAY” Key.
2. Enter your four digit code.
3. DISARMING THE SYSTEM: ----------------- 1. Enter your four digit code.
NOTE: 1. There is a time delay on the entry/exit doors.
2. There is a steady tone upon re-entering. It will not stop until the system is disarmed.
3. The system must be disarmed within 20 seconds, or the siren will come on.