Pump
check tightness
every 6 months
Bolts and seals
check tightness
every 12 months
Heat transfer oil (only valid for oil units)
change
every
4‘000 working hours
For extreme service, the intervals must be shortened accordingly. For temperature control units running with
oil, the oil should be changed yearly, depending on the temperature. Comply with the directives and
recommendations of the oil manufacturer!
13.1 Inspection
Before starting the unit has to be checked the general condition of the temperature control unit, the electrical
connection and the tightness of the connections and hoses (including the consumer).
13.2 Cleaning
The temperature control unit has to be checked and cleaned periodically. Before maintenance the unit has to
be disconnected from the power supply.
13.3 Repair
Established defects must be repaired. To guarantee safety the unit must be repaired with original
MOULDPRO spare parts only.
WARNING
The temperature control unit must be current less before opening!
Press the main switch on the temperature control unit and pull out the mains plug!
There is a danger of electric shock!
Caution
– risk of injury from leaking hot water or oil!
Содержание TCU-200
Страница 10: ... 10 User Guidelines TCU 200 12 06 2019 Vers 003 3 2 Rear view ...
Страница 19: ... 19 User Guidelines TCU 200 12 06 2019 Vers 003 7 Display and Parameter settings Zone A Zone B ...
Страница 38: ... 38 User Guidelines TCU 200 12 06 2019 Vers 003 17 Electrical diagram ...
Страница 39: ... 39 User Guidelines TCU 200 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Страница 40: ... 40 User Guidelines TCU 200 12 06 2019 Vers 003 19 Control Circuit diagram ...
Страница 41: ... 41 User Guidelines TCU 200 12 06 2019 Vers 003 20 Components and spare part list ...