User Guidelines
– TCU-200
12-06-2019
Vers. 003
WARNING
The temperature control unit can release excess pressure. Danger of injury in
the event of escaping steam!
Never start up the unit without the protection cover! Never use the unit in
hazardous location!
Repair leaks immediately! Observe local laws during set-up!
CAUTION
The temperature control unit may be pressurized!
Only when the pressure gauge shows 0 bar, disconnect hoses!
5.2
Connections
Before installing, the connecting lines between temperature control unit and consumer must be subjected
following inspections:
Verify that channels on the consumers are unobstructed
Remove fouling, e.g. remove shaving in the lines
Rust and lime deposits must be removed because the greatly interfere with the heat exchange between
consumer and heat transfer medium and increase the pressure drop in the consumer.
For the connecting lines (to and from mould, cooling water inlet and outlet, etc.) the following internal
diameters of hoses are recommended:
Thread on the unit
Internal hose-Ø
3/8“
10 mm
1/2“
15 mm
3/4“
20 mm
1“
25 mm
DN32
32 mm
Содержание TCU-200
Страница 10: ... 10 User Guidelines TCU 200 12 06 2019 Vers 003 3 2 Rear view ...
Страница 19: ... 19 User Guidelines TCU 200 12 06 2019 Vers 003 7 Display and Parameter settings Zone A Zone B ...
Страница 38: ... 38 User Guidelines TCU 200 12 06 2019 Vers 003 17 Electrical diagram ...
Страница 39: ... 39 User Guidelines TCU 200 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Страница 40: ... 40 User Guidelines TCU 200 12 06 2019 Vers 003 19 Control Circuit diagram ...
Страница 41: ... 41 User Guidelines TCU 200 12 06 2019 Vers 003 20 Components and spare part list ...