ZU25201e_e.doc / Sep-13
Page 18 / 36
8. PC Setup Using the OS3.2 Operator Software
You can apply the full set of functions when you use a PC and our operator software OS3.x for
setup of the unit (actual software version is OS3.2).
You can download this software and more instructions from our homepage
Connect your PC to the converter, using a serial RS232 cable like shown in section 4.6 of this
manual. Make sure the cable only uses pins 2, 3 and 5. Pins 2 and 3 must be crossed.
Run the OS3.x software and you will see the following screen:
If your text and color fields remain empty and the headline says „OFFLINE“, you must verify
your serial settings and the DIL switch setting. To do this, select „Comms“ from the menu bar.
Ex factory, all motrona units use the following serial standard settings:
Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit
If the serial settings of your unit should be unknown, you can run the
„SCAN“ function from the „TOOLS“ menu to find out.
Содержание ZU 252