Display Menu
Parameter changes become active only after closing the menu selection.
START DISPLAY
This parameter defines the start display after switching on device.
0
STANDARD
Display with unit and status bar
1
LARGE
Large display (only the parameter „LARGE DISPLAY“ is active)
2
DOUBLE
Two-line display without units
3 DOUBLE WITH UNITS Two-line display with units
4
COMMAND
Display with command keys
5
QUICKSTART
Display for quick start for enter / display preselection values
(only for option CO/CR/AO/AR/RL)
6 MINIMUM/MAXIMUM Display with minimum and maximum value
SOURCE SINGLE
(Reference source for single-line display and large display)
0
SPEED A
Result of frequency measurement on channel A (or A / B 90)
1 COUNTER A
Result of the counter on channel A (or A / B 90)
2 SECOND COUNTER A
Result of the second counter (total counter / batch counter) on channel A
(or A / B 90)
(Only visible if "Second Mode -A" has been activated.)
3 SPEED B
Result of frequency measurement on channel B
(Only visible if corresponding "Operational Mode" has been activated.)
4 COUNTER B
Result of the counter on channel B
(Only visible if corresponding "Operational Mode" has been activated.)
5 SECOND COUNTER B
Result of the second counter (total counter / batch counter) on channel B
(or A / B 90)
(Only visible if "Second Mode -B" has been activated.)
6 FREQUENCY COLL.
Result of the linked frequency of channel A and B (A+B, A-B, B/A, ...)
(Only visible if corresponding "Operational Mode" has been activated.)
7 COUNTER COLL.
Result of the linked counter of channel A and B (A+B, A-B, B/A, ...)
(Only visible if corresponding "Operational Mode" has been activated.)
8 SCALED RESULT
Result of the additionally scaled process value