- 19 -
2.4 典型接线图
ENTER
RESET
MENU
POWER
RUN
ALARM
TRIP
1
2
3
4
5
6
7
8
AUX. RELAYS
HELP
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
8
9
10
11
12
TB4
T
im
e
D
e
la
y
N
C
C
N
O
N
C
C
N
O
P
.F
.C
.
C
A
P
N
C
C
N
O
N
C
C
N
O
2
3
4
5
6
7
1
8
9
10
11
12
TB3
L
o
c
k
O
u
t
N
C
C
N
O
N
C
C
N
O
F
a
u
lt
N
C
C
N
O
N
C
C
N
O
2
3
4
5
6
7
8
9
10
TB2
2
3
4
5
6
7
1
8
9
10
11
TB1
C
N
O
C
S
N
O
N
C
N
N
N
C
1
N
C
N
C
C
C
C
N
C
N
O
N
O
A
C
N
C
A
C
C
12
Stop
Maintain
Contact
Start
N
TB6
TB7
TB8
NC
Red LED
Red LED
FAULT
FUSE
Green LED
DELAYED
START
Green LED
PFC
TIMED OUT
Green LED
DELAYED
TIMED OUT
7 6 5 4 3 2 1
PFC
7 6 5 4 3 2 1
AUX
7 6 5 4 3 2 1
START
D
L
Y
-C
A
U
X
-C
P
F
C
-C
Jumpers
F1
F2
F3
JP1
Remove JP1 for
electronic Motor
overload protection
During emergency
bypass operation.
SW1
ON
OFF
DUAL ADJ
SW3
SW4
SW5
X
1
X
3
X
5
Power
Supply
POWER
Green LED
EMERGENCY
BYPASS
Green LED
Green LED
Green LED
AUX BYPASS
AT SPEED
2
1
NEUT .
LINE
PERM
PFC
TB5
3
Normally closed dry contact input
.
Emergency Stop Switch
TB
1
6
5
4
3
2
1
12
11
10
9
8
7
6
5
4
3
2
1
12
11
10
9
8
7
6
5
4
3
2
1
TB
2
TB
3
F
1
J
7
J
2
J
1
J
3
J
4
1
1
7
7
J
6
19
20
1
2
J
5
19
20
1
2
X
1
C
1
C
2
A
1
A
2
B
1
B
2
J
8
1
3
1
3
1
6
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
A
U
X
1
(T
R
IP
)
A
U
X
2
(A
L
A
R
M
)
A
U
X
3
(RUN
)
A
U
X
4
(A
T
S
P
E
E
D
)
A
U
X
5
A
U
X
6
A
U
X
7
A
U
X
8
TB1
9
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
TB2
TB3
J1
1
8
1
8
7
6
5
4
3
2
1
CGND1
CGND2
J3
39
40
1
2
J2
CGND4
CGND2
TB4
7 6 5 4 3 2 1
X3
1
3
Bat
2
J5
1
7
J4
J7
19
20
1
2
BT1
+
J6
19
20
1
2
12
13
24
25
36
37
48
TB 1
TB 2
TB 3
TB 4
RTD1
RTD2
RTD3
RTD4
RTD5
RTD6
RTD7
RTD8
RTD9
RTD10
RTD11
RTD12
1
U5
U10
U11
R49
R35
U1
U12
U7
U8
U13
U4
U9
R9
C4
C6+
C9
C7
U2
R15
C17
P1
R6
R10
C
1
0
C11
C31
R2
Q1
Q3
R16
C18
C33
C32
C1
R7
R11
R17
C12
C19
U3
R3
C2
C13
R2
Q3
Q4
X1
C8+
C3
U6
C39
L1
C45
C
38
C
4
4
L2
C43
C37
C
36
C
4
2
1
6
TB1
TB2
J1
(RS485)
X1
(RS422)
X2 X3
1
6
X4
1
7
(RS485)
B+ A- NC NO Shield
(RS422)
Factory Only
A+ A-
B+ B-
Shield
RCV XMIT
Remove Jumper for last unit in Modbus string
三相中压电源
中压或低压电源
CPT*
Ø B
Ø A
Ø C
Ø A
Ø B
H1
H2
X1
X2
H1
H1
H2
H2
X1
X1
X2
X2
H
N
Ø A
Ø B
Ø C
120VAC 120VAC 120VAC
位于中压部分
199
201
180
179
可编程跳线
199
201
180
179
191
192
195
197
189
190
194
193
202
204
189
190
191
192
197
195
202
194
193
204
说明
- TCB
板详细接线见图
2.2.1
NOTE 1
接地故障
保护板
(
可选项
)
零序
CT @ 0.05A
CPU
板
(
见图
2.3.4)
TCB
板
(
见图
2.2.1)
RTD
板
(
见图
2.3.1)
(
可选项
)
光纤套件
主控板
(MB
板
)
(
见图
2.2.3)
A+ A- B+ B-
通讯板
(
见图
2.3.2)
(
后视图
)
J4
RS485
用户通讯接线
6
5
4
3
2
1
Ø A Ø B
Ø C
Ø A
Ø B
Ø C
启动
停车
开关柜
辅助接点
用户可选择
2
线
或
3
线控制方式
(
不可同时使用
)
至功率单元
(
根据型号
)
可选常闭连锁
(出厂短接)
N
H
至可控硅功率单元
键盘操作界面
(
见图
1.9)
A+
A-
No
Connection
S
双绞线
S
常闭干接点输入
连接急停按钮
*CPT (
控制变压器
)
图
2.4
典型接线图