10 Fault Finding
152
Yellow LED No Ethernet
Cable Connected
Yellow LED
Ethernet Cable
Connected between
PIDU Plus and
NIC/Switch/Hub
Valid Ethernet Link
and no traffic
Will be on solid for a
valid link.
Valid Ethernet Link
with traffic
Will be on solid, but
will blink randomly as
traffic passes through
While in “Recovery Mode” the unit will only be
accessible via the IP address 169.254.1.1.
Table 22 - Power Indoor Unit LED check chart
If the above procedures fail to diagnose the issue you may have a wiring fault. Unplug the
RJ45 from the PIDU+ and check the following resistances at the RJ45:
1. Check the cable resistance between pins 1 & 2, 3 & 6, 4 & 5 and 7 & 8 at the RJ45.
2. Check against column 2 in Table 23. Resistances for each pair should be within 1 ohm of
3. Check the cable resistance between pins 1 & 3 at the RJ45. Check against column 3 in
Содержание PTP 54500
Страница 1: ...PTP 500 Series User Guide MOTOROLA POINT TO POINT WIRELESS SOLUTIONS ...
Страница 2: ......
Страница 132: ...8 Web Page Reference 130 Figure 65 Spectrum Management Slave Screen With Operational Restrictions ...
Страница 190: ...14 Data Rate Calculations 188 Figure 111 QPSK 0 50 Single Payload Figure 112 QPSK 0 75 Single Payload ...
Страница 191: ...14 Data Rate Calculations 189 Figure 113 16 QAM 0 50 Single Payload Figure 114 16 QAM 0 75 Single Payload ...
Страница 192: ...14 Data Rate Calculations 190 Figure 115 64 QAM 0 67 Single Payload Figure 116 64 QAM 0 83 Single Payload ...
Страница 193: ...14 Data Rate Calculations 191 Figure 117 QPSK 0 50 Dual Payload Figure 118 QPSK 0 75 Dual Payload ...
Страница 194: ...14 Data Rate Calculations 192 Figure 119 16 QAM 0 50 Dual Payload Figure 120 16 QAM 0 75 Dual Payload ...
Страница 195: ...14 Data Rate Calculations 193 Figure 121 64 QAM 0 67 Dual Payload Figure 122 64 QAM 0 83 Dual Payload ...
Страница 205: ...16 Legal and Regulatory Notices 203 16 4 Exposure See Section 2 Avoiding Hazards ...