Страница 2: ...the 3rd Party software supplied material contained in the Motorola products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Motorola Furthermore the purchase of Motorola products shall not be deemed to grant either directly or by implication estoppel or otherwise any license under the ...

Страница 3: ...rotective earth The Outdoor Unit ODU must be properly grounded to protect against lightning In the USA and Canada it is the user s responsibility to install the equipment in accordance with Section 810 of the National Electric Code ANSI NFPA No 70 1984 or Section 54 of the Canadian Electrical Code These codes describe correct installation procedures for grounding the outdoor unit mast lead in wire...

Страница 4: ... measuring card must NEVER be used at the ODU end connected to power from the PIDU It must only be used at the bottom of the mast with a multimeter This is because the PIDU voltage exceeds the limit allowed in some countries for safe handling in wet conditions and therefore may create a safety hazard Non Motorola power supply Safety may be compromised if a different power supply is used than the o...

Страница 5: ...re not used for connections that will be exposed to the weather RF exposure near the antenna Strong radio frequency RF fields will be present close to the antenna when the transmitter is on Always mute the transmitter before undertaking maintenance activities in front of the antenna Minimum separation distances Install the PTP 600 ODUs so as to provide and maintain the minimum separation distances...

Страница 6: ... card ii Non Motorola power supply ii Alternative DC supplies ii Primary disconnect device iii External cables iii RF exposure near the antenna iii About This User Guide 1 Revision history 2 Version information 2 General information 3 Purpose 3 Cross references 3 Text conventions 4 Contacting Motorola 5 Feedback 5 Motorola Point to Point 5 WiBB Technical Support telephone numbers 6 Reporting probl...

Страница 7: ...DU 1 6 Mounting brackets 1 7 Network connection 1 7 PIDU Plus PTP 300 500 600 Series 1 9 Power and Ethernet LEDs 1 9 ODU LAN and recovery 1 10 DC In and Out 1 10 Remote connectors and jumpers 1 10 Mains connection 1 11 Redundancy and alternative powering configurations 1 11 Remote LEDs and recovery switch 1 14 Cables and connectors 1 15 Outdoor connections 1 15 Indoor connections 1 17 PTP and ligh...

Страница 8: ...27 Security 1 32 Ethernet bridging 1 33 Ethernet frames 1 33 Management function 1 34 Networking information 1 35 Telecoms circuits 1 36 Lowest telecoms modulation mode 1 36 Fixed frequency operation 1 36 Further reading 1 37 System management 1 38 Management agent 1 38 Web interface 1 38 SNMP 1 40 SNMPv3 security 1 42 Email alerts 1 47 AES license 1 48 Critical security parameters 1 49 Capacity u...

Страница 9: ...2 6 Site selection criteria 2 6 Wind loading 2 7 Link planning 2 9 Range and obstacles 2 9 PTP LINKPlanner 2 9 Path loss considerations 2 10 Calculating path loss 2 10 Adaptive modulation 2 10 Planning synchronized networks 2 12 Using PTP LINKPlanner for synchronized networks 2 12 TDD synchronization configuration options 2 12 System threshold output power and link loss 2 17 Lightning protection 2...

Страница 10: ...r module on the equipment building 2 36 Mounting the GPS receiver module on a metal tower or mast 2 37 Chapter 3 Legal information 3 1 Motorola Inc end user license agreement 3 2 Definitions 3 2 Grant of license 3 2 Conditions of use 3 3 Title and restrictions 3 4 Confidentiality 3 4 Right to use Motorola s name 3 5 Transfer 3 5 Updates 3 5 Maintenance 3 5 Disclaimer 3 6 Limitation of liability 3 ...

Страница 11: ...ormation 4 26 PTP 45600 examples of regulatory limits 4 26 PTP 45600 licenses and region codes 4 26 PTP 45600 radio system specifications 4 27 PTP 45600 emissions and radio certifications 4 28 PTP 45600 available spectrum settings 4 29 PTP 45600 system threshold output power and link loss 4 33 PTP 48600 reference information 4 35 PTP 48600 examples of regulatory limits 4 35 PTP 48600 licenses and ...

Страница 12: ...PTP 58600 examples of regulatory limits 4 67 PTP 58600 licenses and region codes 4 70 PTP 58600 regulatory compliance 4 74 PTP 58600 radio system specifications 4 77 PTP 58600 emissions and radio certifications 4 78 PTP 58600 available spectrum settings 4 80 PTP 58600 system threshold output power and link loss 4 83 PTP 58600 FCC antenna restrictions 4 85 PTP 59600 reference information 4 90 PTP 5...

Страница 13: ...ble 5 8 Grounding the drop cable to a metal tower or mast 5 11 Connecting the drop cable to an ODU or LPU 5 16 Disconnecting the drop cable from an ODU or LPU 5 18 Mounting the ODUs 5 19 Mounting bracket 5 19 Hoist and safety loop 5 19 ODU mounting procedure 5 21 Installing the UltraSync GPS receiver 5 23 Recommended kit 5 23 UltraSync unit connections 5 25 Complete UltraSync unit installation 5 2...

Страница 14: ...cable 5 46 Mounting the PIDU Plus 5 48 Installing E1 and T1 5 50 E1 T1 connection diagrams 5 50 Locating the E1 T1 port on the ODU 5 54 Connecting the ODU to the E1 T1 cable 5 55 Routing the cable 5 56 Customer cable termination 5 56 Lightning protection and E1 T1 5 57 Testing the E1 T1 installation 5 58 Establishing a radio link 5 59 Using the ODU installation tones 5 59 Aligning the units 5 60 B...

Страница 15: ...lation 6 72 Graphical install 6 75 Upgrading the PTP 600 6 77 Checking capability summary 6 77 Using access keys to generate a new license key 6 79 Entering a license key 6 80 Saving and restoring system configuration 6 81 Upgrading PTP 600 software 6 84 Remote software upgrade by TFTP 6 88 Managing security 6 90 Configuring user accounts 6 90 Creating or updating identity based users 6 93 Changin...

Страница 16: ...hardware 7 2 Power LED is off 7 5 Power LED is flashing 7 7 Ethernet LED did not flash 10 times 7 7 No Ethernet activity 7 9 Irregular Ethernet activity 7 9 Connection is not 1000 BaseT 7 9 Test Ethernet packet errors reported by ODU 7 10 Test Ethernet packet errors reported by managed switch or router 7 10 Test ping packet loss 7 11 Test resistance at the PIDU end of the drop cable 7 12 Test Ultr...

Страница 17: ...s 8 10 Maximum EIRP 8 10 Cable losses FCC regions only 8 12 Antenna choices 8 13 Antenna selection criteria 8 13 Non FCC regions 8 13 FCC regions 8 13 Installing connectorized bridges 8 14 Cables and connectors 8 14 Tools 8 14 Miscellaneous supplies 8 15 Mounting the connectorized PTP 600 8 15 Mounting the antennas 8 15 Alignment process 8 16 Aligning dual polar antennas 8 16 Aligning separate ant...

Страница 18: ... ODU mounted indoors 8 21 Chapter 9 FAQs 9 1 General FAQs 9 2 Link encryption FAQs 9 4 Encryption data entry fields are not available 9 4 Link fails to bridge packets after enabling link encryption 9 4 Loss of AES following downgrade 9 4 Glossary I Index III ...

Страница 19: ... The TDD cycle of events 1 20 Figure 1 13 Interference between two ODUs on the same mast 1 25 Figure 1 14 PTP SYNC application 1 28 Figure 1 15 PTP SYNC front panel 1 31 Figure 1 16 PTP 600 protocol layers 1 34 Figure 1 17 FIPS 140 2 mode 1 53 Figure 2 1 RTTT channel avoidance example 5 8 GHz UK 2 4 Figure 2 2 TDD synchronization configuration standalone with UltraSync 2 13 Figure 2 3 TDD synchron...

Страница 20: ... PTP 45600 available spectrum in 5 MHz channel bandwidth RC 23 4 31 Figure 4 7 PTP 45600 available spectrum in 20 MHz channel bandwidth RC 24 4 32 Figure 4 8 PTP 45600 available spectrum in 10 MHz channel bandwidth RC 24 4 32 Figure 4 9 PTP 48600 available spectrum in 20 MHz channel bandwidth RC 15 and 23 4 39 Figure 4 10 PTP 48600 available spectrum in 15 MHz channel bandwidth RC 15 and 23 4 40 F...

Страница 21: ...ta rates curve F 4 117 Figure 4 36 PTP 600 range adjustment for data rates curve G 4 118 Figure 4 37 PTP 600 range adjustment for data rates curve H 4 118 Figure 4 38 PTP 600 range adjustment for data rates curve K 4 119 Figure 4 39 PTP 600 range adjustment for data rates curve L 4 119 Figure 4 40 PTP 600 range adjustment for data rates curve N 4 120 Figure 4 41 PTP 600 range adjustment for data r...

Страница 22: ...t synchronized 6 17 Figure 6 7 System administration login page 6 18 Figure 6 8 System Configuration Page 6 20 Figure 6 9 Spectrum Management as seen from the Master 6 25 Figure 6 10 Spectrum Management as seen from the Slave 6 26 Figure 6 11 Example spectrum management graphic 6 28 Figure 6 12 Active channel history screen 6 30 Figure 6 13 Spectrum management time series plot 6 31 Figure 6 14 Spe...

Страница 23: ...configuration 2 6 73 Figure 6 39 Disarm following TDD synchronization 6 74 Figure 6 40 Graphical installation screen 6 75 Figure 6 41 Software License Key page 6 77 Figure 6 42 Reboot Wireless Unit dialog 6 80 Figure 6 43 Reboot Confirmation dialog 6 80 Figure 6 44 Save Restore Configuration page 6 82 Figure 6 45 Software Upgrade page 6 85 Figure 6 46 Software Upgrade Confirmation page 6 86 Figure...

Страница 24: ...Figure 6 72 Reboot Wireless Unit page 6 132 Figure 6 73 Reboot confirmation pop up 6 132 Figure 7 1 Link end hardware test flowchart 1 7 3 Figure 7 2 Link end hardware test flowchart 2 7 4 Figure 7 3 PTP LPU test points 7 8 Figure 7 4 Drop cable tester front and back views 7 13 Figure 7 5 GPS synchronization unit 7 16 Figure 7 6 Recovery Image Warning page 7 20 Figure 7 7 Recovery Options page 7 2...

Страница 25: ...600 Series Wireless Configuration page 8 5 Figure 8 5 Connectorized PTP 600 Series Confirm Installation page 8 7 Figure 8 6 Connectorized PTP 600 Series Disarm Installation page 8 8 Figure 8 7 Forming a drip loop 8 19 Figure 8 8 Weatherproofing the antenna connections 8 19 Figure 8 9 Additional grounding when using connectorized units 8 20 Figure 8 10 Lightning arrestor mounting 8 21 Figure 8 11 P...

Страница 26: ...List of Figures phn 0896_009v003 xxiv UNDER DEVELOPMENT Feb 2010 ...

Страница 27: ...46 Table 1 11 Minimum part number suffix for FIPS 140 2 mode 1 53 Table 2 1 Lateral force imperial 2 7 Table 2 2 Lateral force metric 2 8 Table 4 1 PTP 600 management specifications 4 5 Table 4 2 PTP 600 Ethernet bridging specifications 4 5 Table 4 3 PTP 600 physical specifications 4 6 Table 4 4 PTP 600 power supply specifications 4 6 Table 4 5 PTP 600 telecoms interface specifications 4 7 Table 4...

Страница 28: ...TP 48600 radio certifications 4 38 Table 4 30 PTP 48600 IP mode threshold power and loss per modulation mode 4 43 Table 4 31 PTP 48600 TDM Mode threshold power and loss per modulation mode 4 44 Table 4 32 PTP 49600 examples of regulatory limits 4 45 Table 4 33 PTP 49600 licenses and region codes 4 45 Table 4 34 PTP 49600 RF specifications 4 47 Table 4 35 PTP 49600 EMC emissions compliance 4 48 Tab...

Страница 29: ...4 98 Table 4 62 Throughput for PTP 600 Full link symmetry 1 1 link optimization IP 4 103 Table 4 63 Throughput for PTP 600 Full link symmetry 1 1 link optimization TDM 4 105 Table 4 64 Throughput for PTP 600 Full link symmetry 2 1 link optimization IP 4 107 Table 4 65 Throughput for PTP 600 Full link symmetry 2 1 link optimization TDM 4 109 Table 4 66 Throughput for PTP 600 Full link symmetry Adap...

Страница 30: ...s 6 94 Table 6 11 HTTP and Telnet attributes 6 106 Table 6 12 SNMP attributes in the Remote Management page 6 115 Table 7 1 Expected RJ45 cable resistances at the PIDU Plus 7 15 Table 8 1 Normal EIRP limits with operating channel bandwidth 8 10 Table 8 2 Setting maximum transmit power to meet general EIRP limits 8 11 Table 8 3 Cable losses per length 8 12 ...

Страница 31: ...otorola PTP 600 Series of Point to Point Wireless Ethernet Bridges It is intended for use by the link planner system installer and the end user IT professional The users of this guide will require expertise in the following areas Outdoor radio equipment installation Network configuration Use of web browser for system configuration monitoring and fault finding ...

Страница 32: ...leased Document issue Date of issue Remarks 008v000 Dec 2008 System release 600 08 00 008v004 Apr 2009 System release 600 08 01 008v005 May 2009 System release 600 08 02 008v007 Jul 2009 System release 600 08 03 009v000 Nov 2009 System release 600 08 03 revised 009v003 Feb 2010 System release 600 08 50 under development AUTHOR NOTE Will be published as document issue 010v000 ...

Страница 33: ...ress for any risk of damage loss or reduction in system performance arising directly or indirectly out of the failure of the customer or anyone acting on the customer s behalf to abide by the instructions system parameters or recommendations made in this document Cross references References to external publications are shown in italics Other cross references emphasized in blue text in electronic v...

Страница 34: ...rompts file listings directories utilities and environmental variables that appear on the screen are shown like this Special key sequences Special key sequences are represented as follows CRTL c or CTRL C Press the Ctrl and C keys at the same time CTRL SHIFT c or CTRL SHIFT C Press the Ctrl Shift and C keys at the same time ALT f or ALT F Press the Alt and F keys at the same time ALT SHIFT F11 Pre...

Страница 35: ...tent accuracy or completeness of our documents Send feedback to support ptp motorola com Motorola Point to Point Postal Address Motorola Inc 1303 E Algonquin Road Schaumburg Illinois 60196 U S A Web Site http www motorola com ptp Sales Enquiries sales ptp motorola com Web Support http www motorola com ptp support Email Support support ptp motorola com All Other Enquiries info ptp motorola com ...

Страница 36: ...Middle East and Africa Denmark 043682114 France 0157323434 Germany 06950070204 Italy 0291483230 Lithuania 800 030 828 Netherlands 0202061404 Norway 24159815 Portugal 0217616160 Spain 912754787 Russia 810 800 228 41044 Saudi Arabia 800 844 5345 South Africa 0800981900 United Kingdom 0203 0277499 All other countries 44 203 0277499 Latin and Central America Argentina 0800 666 2789 Brazil 0800 891 436...

Страница 37: ...uipment follow this procedure to investigate and report 1 Search this document and the software release notes of supported releases 2 Visit the Motorola website at http ww motorola com ptp 3 Ask for assistance from the Motorola products supplier 4 Gather information from affected units such as o The IP addresses and MAC addresses o The software releases o The configuration of software features o A...

Страница 38: ...ns and will be free from material defects in material and workmanship under normal use and service Motorola shall within this time at its own option either repair or replace the defective product within thirty 30 days of receipt of the defective product Repaired or replaced product will be subject to the original warranty period but not less than thirty 30 days Details of Motorola s Extended Warra...

Страница 39: ...security practices Security aspects to be considered are protecting the confidentiality integrity and availability of information and assets Assets include the ability to communicate information about the nature of the communications and information about the parties involved In certain instances Motorola makes specific recommendations regarding security practices however the implementation of the...

Страница 40: ...following format WARNING Warning text and consequence for not following the instructions in the warning Cautions Cautions precede instructions and are used when there is a possibility of damage to systems software or individual items of equipment within a system However this damage presents no danger to personnel A caution has the following format CAUTION Caution text and consequence for not follo...

Страница 41: ...ment European Union EU Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE Do not dispose of Motorola equipment in landfill sites In the EU Motorola in conjunction with a recycling partner ensures that equipment is collected and recycled according to the requirements of EU environmental law Disposal of surplus packaging Do not dispose of surplus packaging in landfill sites In the E...

Страница 42: ......

Страница 43: ...scribes the main hardware components The following topics are described in this chapter Product function on page 1 2 Typical deployment on page 1 3 Product variants on page 1 4 Outdoor unit ODU on page 1 6 PIDU Plus PTP 300 500 600 Series on page 1 9 Cables and connectors on page 1 15 PTP and lightning protection on page 1 18 Wireless operation on page 1 19 Ethernet bridging on page 1 33 Telecoms ...

Страница 44: ...modulation and Multiple Input Multiple Output MIMO techniques These technologies enable the PTP 600 Series Bridge to drive through foliage and around buildings to such an extent that almost universal coverage can be expected at short range The PTP 600 Series Bridge has been designed to coexist with other users of the band in an optimal fashion using a combination of Transmit Power Control TPC Spec...

Страница 45: ...ns The PTP 600 Series Bridge is aimed at a wide range of applications An example application is an enterprise that has a requirement to connect together the Local Area Network LAN of two or more buildings as shown in Figure 1 1 Figure 1 1 Typical PTP 600 Series bridge deployment Each end of the link consists of Outdoor Unit ODU An integrated or connectorized see Chapter 8 Connectorized PTP 600 ser...

Страница 46: ... 5 MHz 2572 2614 MHz 5 10 15 30 MHz 6 MHz PTP 25600 FCC BRS EBS Post Transition Band 2618 2690 MHz 5 10 15 30 MHz 5 5 MHz 4404 4596 MHz 5 10 15 20 MHz 6 MHz US Federal 4404 4596 MHz 30 MHz 10 MHz PTP 45600 NTIA 4400 4600 MHz 10 20 MHz 6 MHz US Federal 4710 4940 MHz 5 10 15 20 MHz 5 MHz US Federal Extended 4710 5000 MHz 5 10 15 20 MHz 5 MHz PTP 48600 NTIA 4700 4940 MHz 10 20 MHz 5 MHz USA Canada Pu...

Страница 47: ...ndia 5875 5925 MHz 30 MHz 10 MHz NOTE For PTP 25600 channel widths of 30 MHz are available where allowed by local regulations and subject to some restrictions on channel choice For PTP 58600 ETSI 5 GHz Band C use of the product is only allowed where permitted by country specific regulations Other product variants The Lite versions have lower data throughput rates then the Full versions The PTP 600...

Страница 48: ...ntained unit It houses both radio and networking electronics The ODU for the PTP 600 Series should only be deployed using the supplied PIDU PTP 300 500 600 Series Figure 1 2 shows an installation example of a PTP 600 Series ODU with a Motorola lightning protection unit PTP LPU Figure 1 2 PTP 600 Series outdoor unit ODU with PTP LPU ...

Страница 49: ...unted with the cables dressed to a cable channel Wall mounting is achieved by screwing through the mounting lugs on either side of the unit Remember to leave space for access to the Recovery button See Section PIDU Plus PTP 300 500 600 Series on page 1 9 Network connection The network connection to a PTP 600 Series is made via a 1000BaseT Ethernet connection Power is provided to the ODU over the 1...

Страница 50: ...ptic cable connected directly to the ODU In this case power is still provided over the 1000BaseT Ethernet connection In the case of Fiber Optic cable failure the PTP 600 Series will automatically fall back to the copper Ethernet connection provided the cable length 100m 330 ft PTP 600 Series Optical Interface Upgrade Kits can be obtained from your distributor reseller or system integrator ...

Страница 51: ...TP 600 Series to a PIDU ODU port as equipment damage may occur The PIDU Plus PTP 300 500 600 Series is not interchangeable with the PIDU Plus PTP 400 Series Figure 1 4 Power indoor unit PIDU Plus PTP 300 500 600 Series Power and Ethernet LEDs The front panel contains indicators showing the status of the power and Ethernet connections The Power indicator is illuminated when the PIDU is receiving ma...

Страница 52: ...r the power has been applied Full instruction on the recovery mode can be found in Using recovery mode on page 7 20 A simple reboot can be performed by removing and re applying the mains power to the PIDU Plus DC In and Out On the left hand side of the PIDU Plus 48V DC input and output connections can be found These are used to power the PTP 600 Series from an external DC source or to provide a le...

Страница 53: ...n be powered from an external DC source and can be provided with power supply redundancy as follows External DC supply only Figure 1 8 This configuration is for use where there is no mains supply External DC supply and AC supply Figure 1 9 This configuration provides redundancy through the use of mains and DC supply External DC supply and redundant AC Supply Figure 1 10 This configuration guards a...

Страница 54: ...VELOPMENT Feb 2010 Figure 1 7 Relationship between DC voltage and cable length CAUTION The maximum distance from the ODU to the connected network equipment is 100m 330 ft when using 1000BaseT Powering distances over 100m 330 ft are only applicable when using a 1000BaseSX Fiber Optic connection ...

Страница 55: ...User Guide PTP 600 Series PIDU Plus PTP 300 500 600 Series phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 1 13 Figure 1 8 External DC supply only Figure 1 9 External DC supply and AC supply ...

Страница 56: ... provides a facility to connect remote LEDs and Recovery switch allowing the PIDU Plus to be mounted inside an enclosure At the left hand end of the PIDU Plus under the ODU connection cover can be found a PCB header and three jumpers Jumpers J906 and J907 should be removed and connection to the remote LEDs and Recovery switch made to J908 as shown in Figure 1 11 Figure 1 11 Remote LED and recovery...

Страница 57: ...r Essex cable The only type of outdoor drop cable supported by Motorola is Superior Essex CAT5e which is UV resistant and has a screened shield The available lengths and part numbers are specified in Table 1 2 CAUTION Alternative types of drop cable are not supported by Motorola as they may increase the risk of lightning damage to the installation See Lightning protection on page 2 18 Table 1 2 Su...

Страница 58: ...Crimp tool Tyco AMP 2 231652 Die set Tyco AMP 1 8534400 0 Gland Motorola WB1811 The recommended connectors and glands to be used for connecting the supported Superior Essex cable to the Trimble GPS receiver are specified in Table 1 4 Table 1 4 Recommended outdoor connectors for Trimble GPS receiver Item Manufacturer Part number 12 way circular connector Deutsch IMC26 2212X Size 22 crimp socket Deu...

Страница 59: ...for indoor cables are specified in Table 1 5 Table 1 5 Recommended indoor CAT5e connectors Item Manufacturer Part number Connector Tyco AMP 336330 1 Crimp tool Tyco AMP 790163 1 includes die set The PIDU Plus provides screen continuity between the ODU and network equipment connections NOTE The ODU network connection implements automatic MDI MDI X sensing and pair swapping allowing connection to ne...

Страница 60: ...o nearby lightning strikes To be fully effective these standard features require some additional equipment to be configured as part of the system installation A separate Ethernet surge suppressor must be used and appropriately earthed Suitable surge suppressors can be sourced from your Motorola Point to Point Distributor or Solutions Provider See Lightning protection on page 2 18 CAUTION Motorola ...

Страница 61: ...ating between the two ends The cycle of events is illustrated in Figure 1 12 with the sequence being described as follows 1 Master transmits a burst to the Slave 2 A delay occurs as the Master burst propagates over the air 3 Slave receives the burst from the Master 4 A delay as the Slave processes the burst 5 The slave transmits a burst to the Master 6 A delay as the slave burst propagates over th...

Страница 62: ...mization and Link Symmetry When TDD synchronization is enabled see TDD synchronization configuration on page 6 66 the user must configure the TDD Frame which includes configuration of Burst Duration and Frame Duration Link mode optimization Link mode optimization allows the PTP 600 link to be optimized according to the type of traffic that will be bridged The link supports two modes IP Traffic and...

Страница 63: ...uration of the Master to twice that of the Slave Note that this mode is not available when TDD synchronization is enabled see section TDD Synchronization 1 2 The capacity in the direction Slave to Master is twice that of the direction Master to Slave The PTP 600 series achieves this by setting the Burst Duration of the Slave to twice that of the Master NOTE This mode is not available when TDD sync...

Страница 64: ...MHz 20 MHz and 30 MHz Higher bandwidths provide greater link capacity at the expense of using more spectrum Systems configured for a narrower channel bandwidth provide better receiver sensitivity and can also be an appropriate choice in deployments where the amount of free spectrum is limited NOTE The Channel Bandwidth must be configured to the same value at both ends of the link Not all channel b...

Страница 65: ...tion mode MIMO The PTP 600 transmits two signals on the same radio frequency one which is vertically polarized the other which is horizontally polarized The PTP 600 also has the ability to adapt between two modes of operation Dual Payload When the radio channel conditions allow the PTP 600 will transmit two different and parallel data streams one on the vertical channel and one on the horizontal c...

Страница 66: ...quires that equipment used in the region Detects interference from other systems and avoids co channel operation with these systems notably radar systems Provides a uniform loading of the spectrum across all devices that is fixed frequency operation is not allowed To address the primary aims the spectrum management algorithm implements a radar detection function which looks for impulsive interfere...

Страница 67: ...etic interference to which it is subjected This is also true for the PTP 600 ODUs In an ideal environment any individual ODU will only receive transmissions from the paired ODU at the other end of the link However when multiple PTP 600 links are installed an ODU may also be subjected to interference from the transmission of an ODU which is part of another link The levels of interference become ver...

Страница 68: ... is achieved by connecting each Master PTP 600 to a synchronization unit One synchronization unit is required for each Master Two alternative synchronization units are available MemoryLink UltraSync GPS receiver This unit contains a GPS receiver which produces the common network timing reference For more information refer to UltraSync on page 1 27 PTP SYNC This option is the preferred solution For...

Страница 69: ...DD synchronization is disabled The term ideal is important as this is the capacity assuming that there is no interference The benefit of eliminating half of the network interference mechanisms generally outweighs this small reduction in capacity The exact reduction can be examined using Link Planner UltraSync PTP 600 application software supports the synchronization method based on the MemoryLink ...

Страница 70: ...a standard 19 inch rack The PTP SYNC is powered using standard PTP 600 power over Ethernet from the PIDU One PTP SYNC unit is required for each synchronized link How PTP SYNC works TDD synchronization using the PTP SYNC operates as follows 1 The timing reference generates a precise 1 Hz signal that is synchronised in both frequency and phase with a network wide master 2 The PTP 600 ODU generates a...

Страница 71: ... one of the following A separate timing source typically a GPS receiver connected directly to the PTP SYNC or through another PTP SYNC in a daisy chain arrangement as shown in Figure 1 14 In networks where all master ODUs are collocated for example a network consisting of a single hub it is possible to use PTP SYNCs in the standard scheme but omitting the external timing source In this case one OD...

Страница 72: ...mended GPS receiver continues to provide accurate timing even after the number of received satellite has dropped down to one leading to significantly better availability of the reference signal The PTP SYNC offers the possibility of creating synchronised single hub networks where no GPS receiver is required ...

Страница 73: ...e 1 6 PTP SYNC front panel interfaces Number Description Function 1 GPS SYNC IN Input from GPS receiver module 2 SYNC OUT Output to cascaded GPS SYNC units 3 USB Input for software upgrades Contact Motorola for instructions 4 1PPS IN Coaxial alternative to GPS SYNC IN Peak input suppy must not exceed 5V 5 LED bank LEDs and their functions are described in Table 1 7 6 PIDU IN Input from PIDU 7 ODU ...

Страница 74: ...ing received at the SYNC OUT port Off No power On steady Power but no satellite lock STATUS Blink Power and satellite lock at either the GPS SYNC IN or 1PPS IN port Off No signal being received from the ODU ODU On Communication with the ODU is established Security Encryption standard used The Motorola PTP 600 Series supports link encryption using the NIST approved Advanced Encryption Standard FIPS...

Страница 75: ...idges appears to the data network to be very similar to a standard two port Ethernet bridge The PTP 600 series provides eight traffic classes classifying Ethernet frames into one of eight prioritized queues based on inspection of the user priority field 802 1p in a customer IEEE802 1Q VLAN tag or provider IEEE802 1ad VLAN tag Untagged frames receive a default priority The scheduling method is stri...

Страница 76: ...2c or 1 SMTP HTTP Telnet IP MAC Relay Ethernet MAC Ethernet MAC Ethernet PHY PTP MAC PTP PHY Ethernet medium Ethernet MAC PTP MAC PTP PHY MAC Relay Ethernet MAC Ethernet PHY Ethernet PHY Ethernet MAC TCP UDP ICMP HTTPS TLS SNMP v3 2c or 1 SMTP HTTP Telnet IP Ethernet medium Radio medium Management function Management function Bridge function Bridge function Master ODU Slave ODU Each unit in the li...

Страница 77: ...Networking information The PTP 600 Series operates as a transparent Ethernet bridge Although each unit requires an IP address this IP address is for management purposes only and it plays no part in the forwarding of bridged Ethernet frames IP addresses are assigned during initial configuration ...

Страница 78: ...d this necessarily results in somewhat lower availability for the telecoms circuit The loss of availability can be estimated using the LINKPlanner The unit will override the user setting of Lowest Telecoms Modulation Mode if the selected mode has insufficient capacity to carry the telecoms data or if the mode demands very high latency and requires more buffering than the link can provide When the ...

Страница 79: ...010 UNDER DEVELOPMENT 1 37 Further reading Installation details are provided in Installing E1 and T1 on page 5 50 E1 T1 circuits are configured using the web pages described in Section Configuring the telecoms circuits on page 6 49 and Telecoms interface on page 6 57 ...

Страница 80: ...out requiring any special management software The web based interface is the only interface supported for installation of PTP 600 and for the majority of PTP 600 configuration management tasks There are two servers HTTP and HTTPS which depending on prevailing licence key can be independently controlled Management tasks using the web based management interface are described in detail in Chapter 6 O...

Страница 81: ...cific network applications Security wizard The web based interface includes a Security Wizard The Security Wizard is used to enter configuration for TLS including the key or keys private key public key certificate and entropy value The Security Wizard additionally allows HTTP and Telnet interfaces to be disabled and encryption keys to be entered or updated for AES encryption at the wireless interf...

Страница 82: ...ral o One special character When the password is changed the new password must differ from the previous password by at least four characters Special characters are any of the following _ Best practice passwords can be checked in role based and identity based authentication methods SNMP The management agent supports fault and performance management by means of an SNMP interface The management agent...

Страница 83: ... PTP 600 supports the following diagnostic alarms Region Code Install Status Install Arm State Unit Out Of Calibration Incompatible Region Codes Incompatible Master And Slave Ethernet Configuration Mismatch No Wireless Channel Available SNTP Synchronisation Failed Wireless Link Disabled Warning Ethernet Link Disabled Warning Ethernet Link Status Fiber Link Status Telecoms Channel A Status Telecoms...

Страница 84: ...P Address SNMP Trap Port Number SNMP Community String SNMPv3 security Secure configuration PTP 600 provides a default SNMPv3 configuration This initial configuration is not secure but it provides the means by which a secure configuration can be created The secure configuration should be configured in a controlled environment to prevent disclosure of the initial security keys necessarily sent as pl...

Страница 85: ...stored when all PTP 600 configuration data is erased using Erase configuration on page 7 25 or when all SNMP users are deleted using the SNMP management interface Default configuration for the usmUserTable table is based on one initial user and four template users as listed in Table 1 8 Table 1 8 Default SNMPv3 users Object Entry 1 Name initial SecurityName initial AuthProtocol usmHMACMD5AuthProto...

Страница 86: ...uthentication and privacy keys and with appropriate access to the whole of the MIB or to particular views of the MIB according to the operator s security policy New users must be created by cloning template users The user initial may then be deleted to prevent access using the well known user name and keys Alternatively the keys associated with initial may be set to some new secret value View base...

Страница 87: ... Guide PTP 600 Series System management phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 1 45 ViewName internet restricted Subtree 1 3 6 1 1 3 6 1 Mask Type included included StorageType nonVolatile nonVolatile ...

Страница 88: ...ed at the wireless interface Neither is it possible to read or modify security parameters associated with TLS protection of the web based management interface The recovery mode option to zeroise CSPs does not affect SNMPv3 configuration Downgrade of the license key A possible lockout condition exists if a user downgrades the PTP 600 license key so as to disable the AES capability when SNMPv3 users...

Страница 89: ...t Link Up Down Region Code Install Status Install Arm State Unit Out Of Calibration Incompatible Region Codes Incompatible Master And Slave Ethernet Configuration Mismatch No Wireless Channel Available SNTP Synchronisation Failed Wireless Link Disabled Warning Ethernet Link Disabled Warning Ethernet Link Status Fiber Link Status Telecoms Channel A Status Telecoms Channel B Status Telecoms Channel ...

Страница 90: ... must be rebooted before AES can be enabled Once applied the AES upgrade is bound to a single ODU and is not transferrable AES encryption may be used in the following ways At the wireless port to encrypt data transmitted over the wireless link At the SNMP management interface in the SNMPv3 mode At the HTTP management interface in the TLS mode Two levels of encryption are available to purchase 128 ...

Страница 91: ...ecting the Zeroise CSPs option in Recovery mode Capacity upgrades Capacity upgrades are supplied as an access key purchased from your Motorola Point to Point distributor or solutions provider The upgrade is applied by entering an access key together with the MAC address of the target ODU into the PTP License Key Generator web page which may be accessed from http www motorola com ptp support The Li...

Страница 92: ...a The management process for software upgrade is described in detail in Upgrading the PTP 600 on page 6 77 Software can be downgraded using Recovery mode as described in Recovery mode on page 1 50 Recovery mode The PTP 600 recovery mode provides a means to recover from serious configuration errors including lost or forgotten passwords and unknown IP addresses Recovery mode also allows new main app...

Страница 93: ...parameters Reset IP and Ethernet configuration to factory default Erase zeroize critical security parameters Reboot with existing software and configuration NOTE If recovery mode has been entered either because of a checksum error by default the ODU will reboot with existing software and configuration following a 30 second wait The recovery software image is installed during manufacture of the ODU...

Страница 94: ...as FIPS operation enabled The hardware security of the ODU is compatible with operation in the FIPS 140 2 mode The HTTPS TLS management interface is enabled The HTTP management interface is disabled The Telnet management interface is disabled Validated software image FIPS validated software images are indicated by a FIPS prefix to the file name for example FIPS PTP600 08 50 DLD2 The general featur...

Страница 95: ...PTP 25600 BB PTP 45600 BB PTP 48600 AA PTP 49600 AA PTP 54600 EE PTP 58600 DD PTP 59600 BB The ODU will also have compatible hardware security if the part number suffix is earlier and PTP 600 Hardware Security Upgrade has been applied The Hardware Security Upgrade Kit is available as Motorola part number WB3593AA FIPS 140 2 mode indication The FIPS 140 2 mode is indicated by a distinctive symbol d...

Страница 96: ...a PTP 600 license key that has FIPS operation disabled and reboot Load PTP 600 software that is not FIPS validated and reboot Zeroise CSPs and reboot The critical security parameters CSPs are always erased zeroised on exit from FIPS 140 2 mode Prerequisites CAUTION To operate in FIPS 140 2 mode ensure that you use o A FIPS approved cryptographic key generator o A FIPS approved X509 RSA public priv...

Страница 97: ...loss and wind loading The following topics are described in this chapter Spectrum planning on page 2 2 Licenses and region codes on page 2 3 Radar avoidance and bandwidth operation on page 2 4 Variable channel bandwidth operation on page 2 5 Site planning on page 2 6 Link planning on page 2 9 Path loss considerations on page 2 10 Planning synchronized networks on page 2 12 System threshold output ...

Страница 98: ...e can be influenced in its channel decision process by selectively barring channels from use Fixed Frequency This method allows the installer to allocate fixed transmit and receive frequencies on the units Regions with mandatory radar detection In regions that mandate DFS Radar Detection the frequency must always be symmetrical transmit and receive on the same frequency The Spectrum Management Con...

Страница 99: ...he appropriate integrated antenna the regulations may require the maximum Tx power to be reduced To ensure that regulatory requirements are met for connectorized installations refer to Regulatory issues with connectorized units on page 8 10 The license and region codes for each frequency variant are listed in PTP 25600 licenses and region codes on page 4 17 PTP 45600 licenses and region codes on p...

Страница 100: ...z bandwidth Figure 2 1 where blocks in red indicate channels that are barred Barred channels are indicated by a No Entry symbol displayed on the Spectrum Management web page see Spectrum management control with radar avoidance on page 6 34 Figure 2 1 RTTT channel avoidance example 5 8 GHz UK NOTE Radar avoidance requirements in the 5 4GHz band in the EU is detailed in specification EN 301 893 vers...

Страница 101: ...s on channel choice Lite versions of the PTP 600 products do not support a Channel Bandwidths of 5 MHz Configuration of the variable bandwidth operation must be symmetric that is the Transmit and receive channels must use identical Channel Bandwidths For details of the spectrum settings that are available to each frequency variant refer to PTP 25600 available spectrum settings on page 4 21 PTP 456...

Страница 102: ...nning permission issues Distance from the ODU and connected Network equipment Maximum cable run from the ODU to the connected equipment is 100m 330 ft Distance from the PIDU Plus to the ODU Maximum cable run from the PIDU Plus to the ODU is 300m 990 ft when using the Fiber interface If using the GPS Sync Unit ensure that it is exposed to an unobstructed path to the sky Please refer to the GPS Sync...

Страница 103: ...tion of lateral force The PTP 600 Series with or without the integral antenna is essentially a flat structure and so the magnitude of the lateral force can be estimated from Force in pounds 0 0042 A v2 Where A is the surface area in square feet and v is the wind speed in miles per hour The lateral force produced by a single 600 Series integrated or connectorized model at different wind speeds is s...

Страница 104: ...ure Capabilities of the PTP 600 Series The structure and mounting brackets of the PTP Series systems are capable of withstanding wind speeds up to 151mph 242 kph The installer should ensure that the structure to which the PTP 600 Series is fixed to is also capable of withstanding the prevalent wind speeds and loads Wind speed statistics Installers are recommended to contact the national meteorolog...

Страница 105: ...ansmitting at higher power in a non optimal direction thereby increasing interference in the band A survey must be performed to identify all the obstructions such as trees or buildings in the path and to assess the risk of interference This information is important if you are to achieve an accurate link feasibility assessment PTP LINKPlanner Link planning enables a link of known quality to be inst...

Страница 106: ...judge whether a particular link can be installed Equation 2 1 Path loss capability seasonal fade excess space free L L L L L _ Where space free L _ Free Space Path Loss dB excess L Excess Path Loss dB fade L Fade Margin Required dB seasonal L Seasonal Fading dB capability L Equipment Capability dB Adaptive modulation Adaptive modulation ensures that the highest throughput that can be achieved inst...

Страница 107: ...power will be reduced on the edge channels and may vary if different region codes are selected AMOD Threshold The AMOD threshold is the combined receive input signal level on both horizontal and vertical inputs that results in the link consistently entering the receive modulation mode under consideration as the signal level is increased System Threshold Thresholds for all modes except BPSK are for...

Страница 108: ...re a site contains only one TDD master ODU The GPS Receiver and LPU can be replaced by an alternative compatible 1 Hz timing reference Cluster with PTP SYNC and GPS receiver Figure 2 4 Each link requires one PTP SYNC unit Each site requires one compatible GPS receiver Collocated PTP SYNC units are connected together in a daisy chain Use this configuration where a site contains collocated TDD maste...

Страница 109: ...User Guide PTP 600 Series Planning synchronized networks phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 2 13 Figure 2 2 TDD synchronization configuration standalone with UltraSync ...

Страница 110: ...hronization configuration standalone with PTP SYNC PIDU 100 240 V ac ODU LAN AC supply Customer network PTP SYNC PIDU IN ODU OUT GPS SYNC IN SYNC OUT LPU Outside Inside GPS Receiver LPU PTP 600 ODU PIDU Drop cable LPU Master Slave Mode Master TDD Sync Device PTP Sync PTP Sync Site Ref GPS 1PPS Ext Cluster Master Slave Cluster Master ...

Страница 111: ...User Guide PTP 600 Series Planning synchronized networks phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 2 15 Figure 2 4 TDD synchronization configuration cluster with PTP SYNC and GPS ...

Страница 112: ...U Drop cable Additional PIDUs Additional PTP SYNCs PTP SYNC PIDU IN ODU OUT GPS SYNC IN SYNC OUT PIDU 100 240 V ac ODU LAN LPU LPU PTP 600 ODU PIDU PTP SYNC PIDU IN ODU OUT GPS SYNC IN SYNC OUT PIDU 100 240 V ac ODU LAN Customer network Master Slave Mode Master TDD Sync Device PTP Sync PTP Sync Site Ref Internal Cluster Master Slave Cluster Master Master Slave Mode Master TDD Sync Device PTP Sync ...

Страница 113: ...channel bandwidths refer to PTP 25600 system threshold output power and link loss on page 4 24 PTP 45600 system threshold output power and link loss on page 4 33 PTP 48600 system threshold output power and link loss on page 4 43 PTP 49600 system threshold output power and link loss on page 4 51 PTP 54600 system threshold output power and link loss on page 4 62 PTP 58600 system threshold output pow...

Страница 114: ...e 2 21 LPU kit on page 2 22 LPU installation wiring on page 2 24 Site installation diagrams on page 2 26 This section should be treated as a guide only The actual degree of lightning protection required depends on local conditions and weather patterns and applicable local regulations Full details of lightning protection methods and requirements can be found in the international standards IEC 61024...

Страница 115: ... Zone A In this zone a direct lightning strike is possible Do not mount the ODU and antenna in this zone Zone B In this zone direct EMD lightning effects are still possible but mounting in this zone significantly reduces the possibility of a direct strike Mount the ODU and antenna in this zone WARNING Never mount the ODU in Zone A Mounting in Zone A may put equipment structures and life at risk Fi...

Страница 116: ...e the sphere rests on two finials the space under the sphere is considered in the zone of protection Grounding considerations The PTP 600 Series ODU grounding point can be found on the bottom of the unit The ODU is supplied with an appropriate grounding lug The following protection requirements are mandatory The ODU must be earthed Screened CAT 5e cable must be used Surge arrestors of type PTP LPU...

Страница 117: ...ed part of the installation of a link This is the configuration recommended by Motorola Option 2 Using the U Bolt bracket supplied with the PTP LPU Kit Typical examples of these two configurations are shown in Figure 2 7 and Figure 2 8 CAUTION Grounding Points are shown unprotected for clarity Grounding points should be weatherproofed to prevent corrosion and possible loss of ground continuity Fig...

Страница 118: ...nfiguration option 2 U bolt A second Lightning protection Unit should be mounted at the building entry point and must be grounded LPU kit Standard kit with two LPUs The standard PTP LPU kit Figure 2 9 contains two LPUs grounding cables and a 600mm ODU to LPU cable pre fitted with glands The Motorola part number for this kit is WB2907AA ...

Страница 119: ...tection phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 2 23 Figure 2 9 PTP LPU full kit The cable between the two LPUs top and bottom should be of the recommended type see Cables and connectors on page 1 15 and terminated as shown in Figure 5 1 ...

Страница 120: ...0 Additional kit with one LPU Some installation options for example PTP SYNC with Trimble GPS receiver may require an additional single LPU kit Figure 2 10 Figure 2 10 PTP LPU additional kit LPU installation wiring Figure 2 11 shows the correct installation wiring for a PTP 600 with lightning protection ...

Страница 121: ...User Guide PTP 600 Series Lightning protection phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 2 25 Figure 2 11 Simplified circuit diagram ...

Страница 122: ...8 per link 2 or 4 Motorola Kits Part Number WB2907AA Grounding stake Grounding cable minimum size 8 AWG preferably 6 or 4 AWG RJ45 screened connectors Additional components are listed under each diagram where required The recommended cables are specified in Cables and connectors on page 1 15 There may be a local regulatory requirement to cross bond the CAT 5e cable to the mast or tower at interval...

Страница 123: ...installation diagrams phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 2 27 NOTE If a coaxial or other cable is already cross bonded to the mast or tower the same cross bonding points on the mast or tower must be used for the CAT 5e cable ...

Страница 124: ... Typical mast or tower installation Figure 2 12 shows a typical PTP 600 Series mast or tower installation using PTP LPU Surge protection for a configuration without a GPS sync unit or E1 T1 ports This installation requires 4 Motorola PTP LPU surge arrestors 2 kits Figure 2 12 Typical mast or tower installation ...

Страница 125: ...MENT 2 29 Typical wall installation Figure 2 13 shows a typical PTP 600 Series wall installation using PTP LPU surge protection for a configuration without a GPS sync unit or E1 T1 ports This installation requires 4 Motorola PTP LPU surge arrestors 2 kits Figure 2 13 Typical wall installation ...

Страница 126: ...010 Mast or tower installation with E1 T1 Figure 2 14 shows a typical PTP 600 Series mast or tower installation using PTP LPU surge protection for a configuration that includes E1 T1 ports This installation requires 8 Motorola PTP LPU surge arrestors 4 kits Figure 2 14 Mast or tower installation with E1 T1 ...

Страница 127: ... DEVELOPMENT 2 31 Wall installation with E1 T1 Figure 2 15 shows a PTP 600 Series wall installation using PTP LPU surge protection for a configuration that includes E1 T1 ports This installation requires 8 Motorola PTP LPU surge arrestors 4 kits Figure 2 15 Wall installation with E1 T1 ...

Страница 128: ...hows a PTP 600 Series mast or tower installation using PTP LPU surge protection for a configuration that includes an UltraSync GPS sync unit This installation requires 4 Motorola PTP LPU surge arrestors 2 kits This installation also requires UltraSync GPS sync unit from MemoryLinkl 1 per link 1 Motorola kit Figure 2 16 Mast or tower installation with UltraSync GPS sync unit ...

Страница 129: ...hows a PTP 600 Series wall installation using PTP LPU surge protection for a configuration that includes an UltraSync GPS sync unit This installation requires 4 Motorola PTP LPU surge arrestors 2 kits This installation also requires one UltraSync GPS sync unit from MemoryLink per link 1 Motorola kit Figure 2 17 Wall installation with UltraSync GPS sync unit ...

Страница 130: ...TP 600 Series mast or tower installation using PTP LPU surge protection for a configuration that includes an UltraSync GPS sync unit and E1 T1 ports This installation requires 8 Motorola PTP LPU surge arrestors 4 kits This installation also requires UltraSync GPS sync unit from MemoryLinkl 1 per link 1 Motorola kit Figure 2 18 Mast or tower installation with UltraSync GPS sync unit and E1 T1 ...

Страница 131: ...TP 600 Series wall installation using PTP LPU surge protection for a configuration that includes an UltraSync GPS sync unit and E1 T1 ports This installation requires 8 Motorola PTP LPU surge arrestors 4 kits This installation also requires UltraSync GPS sync unit from MemoryLinkl 1 per link 1 Motorola kit Figure 2 19 Wall installation with UltraSync GPS sync unit and E1 T1 ...

Страница 132: ...ailing that mount it on a metal tower or mast Mounting the GPS receiver module on the equipment building If mounting the GPS receiver module on the equipment building Figure 2 20 select a position on the wall that meets the following requirements It must have an un interrupted view of the sky It must receive an adequate signal from at least one GPS satellite It must be in Zone B refer to Lightning...

Страница 133: ... position that meets the following requirements It must have an un interrupted view of the sky It must not be mounted any higher than is necessary to receive an adequate signal from a GPS satellite It must be lower than the top of the tower or its lightning terminal and finial It must be protected by a nearby lightning terminal or finial that projects further out from the tower than the GPS receiv...

Страница 134: ...Rack Ground Bar RGB Equipment Rack PTP SYNC Cable Ground Kit note 1 Cable Ground Kit Cable Ground Kit Master Ground Bar MGB PTP SYNC Ground Cable Ground Bus Conductor GPS Rx Module to LPU cable Superior Essex Cable screened shield Note 1 Additional ground kits shall be installed as necessary to reduce the distance between ground kits to 61m 200ft or less In high lightning prone areas additional gr...

Страница 135: ... modifications to the equipment must not be made unless under the express consent of the party responsible for compliance Any such modifications could void the user s authority to operate the equipment and will void the manufacturer s warranty The following topics are described in this chapter Motorola Inc end user license agreementon page 3 2 Hardware warranty on page 3 12 Limit of liability on p...

Страница 136: ... TERMS OF THIS AGREEMENT Definitions In this Agreement the word Software refers to the set of instructions for computers in executable form and in any media which may include diskette CD ROM downloadable internet hardware or firmware licensed to you The word Documentation refers to electronic or printed manuals and accompanying instructional aids licensed to you The word Product refers to Motorola...

Страница 137: ...ing except that you may either i make 1 copy of the transportable part of the Software which typically is supplied on diskette CD ROM or downloadable internet solely for back up purposes or ii copy the transportable part of the Software to a PC hard disk provided you keep the original solely for back up purposes If the Documentation is in printed form it may not be copied If the Documentation is i...

Страница 138: ...ackage without Motorola s written consent Unauthorized copying of the Software or Documentation or failure to comply with any of the provisions of this Agreement will result in automatic termination of this license Confidentiality You acknowledge that all Software and Documentation contain valuable proprietary information and trade secrets and that unauthorized or improper use of the Software and ...

Страница 139: ... may be conditioned upon transferee paying all applicable license fees and agreeing to be bound by this Agreement Updates During the first 12 months after purchase of a Product or during the term of any executed Maintenance and Support Agreement for the Product you are entitled to receive Updates An Update means any code in any form which is a bug fix patch error correction or minor enhancement bu...

Страница 140: ...RANTY WITH RESPECT TO THE CORRECTNESS ACCURACY OR RELIABILITY OF THE SOFTWARE AND DOCUMENTATION Some jurisdictions do not allow the exclusion of implied warranties so the above exclusion may not apply to you Limitation of liability THE TOTAL LIABILITY OF MOTOROLA UNDER THIS AGREEMENT FOR DAMAGES WILL NOT EXCEED THE TOTAL AMOUNT PAID BY YOU FOR THE PRODUCT LICENSED UNDER THIS AGREEMENT IN NO EVENT ...

Страница 141: ...nsistent with the rights provided to you under the aforementioned provisions of the FAR and DFARS as applicable to the particular procuring agency and procurement transaction Term of license Your right to use the Software will continue in perpetuity unless terminated as follows Your right to use the Software will terminate immediately without notice upon a breach of this Agreement by you Within 30...

Страница 142: ...t govern your use of any Third Party Software UNLESS A SEPARATE THIRD PARTY SOFTWARE LICENSE IS INCLUDED IN WHICH CASE YOUR USE OF THE THIRD PARTY SOFTWARE WILL THEN BE GOVERNED BY THE SEPARATE THIRD PARTY LICENSE Software The following is a list of the third party computer software copyrights contained within this Motorola product Vendor Copyright UCD SNMP Copyright 1989 1991 1992 by Carnegie Mel...

Страница 143: ...ibution of the software without specific written permission CMU AND THE REGENTS OF THE UNIVERSITY OF CALIFORNIA DISCLAIM ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS IN NO EVENT SHALL CMU OR THE REGENTS OF THE UNIVERSITY OF CALIFORNIA BE LIABLE FOR ANY SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM T...

Страница 144: ... Altered source versions must be plainly marked as such and must not be misrepresented as being the original software The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERC...

Страница 145: ...nted to anyone to use this software for any purpose including commercial applications and to alter it and redistribute it freely subject to the following restrictions The origin of this software must not be misrepresented you must not claim that you wrote the original software If you use this software in a product an acknowledgment in the product documentation would be appreciated but is not requi...

Страница 146: ... Motorola warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service Motorola shall within this time at its own option either repair or replace the defective product within thirty 30 days of receipt of the defective product Repaired or replaced product will be subject to the original w...

Страница 147: ...LITY TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS OR FROM ANY BREACH OF WARRANTY EVEN IF MOTOROLA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation ma...

Страница 148: ...Limit of liability Chapter 3 Legal information phn 0896_009v003 3 14 UNDER DEVELOPMENT Feb 2010 ...

Страница 149: ...nt The following topics are described in this chapter PTP 600 general reference information on page 4 2 PTP 25600 reference information on page 4 16 PTP 45600 reference information on page 4 26 PTP 48600 reference information on page 4 35 PTP 49600 reference information on page 4 45 PTP 54600 reference information on page 4 53 PTP 58600 reference information on page 4 67 PTP 59600 reference inform...

Страница 150: ...e 8 10 FCC and ETSI compliance testing The system has been tested for compliance to both US FCC and European ETSI specifications It has been shown to comply with the limits for emitted spurious radiation for a Class B digital device pursuant to Part 15 of the FCC Rules in the USA and appropriate European ENs These limits have been designed to provide reasonable protection against harmful interfere...

Страница 151: ...e local regulator may limit the amount of conducted or radiated transmitter power and may require registration of the radio link The power transmitted by the PTP 600 Series is controlled by the use of Region specific License Keys Contact your supplier installer to ensure that your product is set for the correct License Key for your Country Region and to ensure that you have fulfilled all the local...

Страница 152: ...ER DEVELOPMENT Feb 2010 Registration of links UK Registration of Links OfCom The application form may be found at http www ofcom org uk radiocomms isu Eire Registration of Links Commission for Communication Regulation The application form may be found at http www comreg ie licensing_and_services ...

Страница 153: ...l installation tool suitable for laptop and PDA computing devices Installation Web server for confirmation Radio Performance and Management Via web server and browser SNMP Alarms Via configurable email alerts SNMP Table 4 2 PTP 600 Ethernet bridging specifications Ethernet Bridging Specification Protocol IEEE802 1 IEEE802 1p IEEE802 3 compatible QoS IEEE 802 1p eight levels IEEE 802 1Q IEEE 802 1a...

Страница 154: ...le 4 3 PTP 600 physical specifications Integrated Specification Dimensions Width 14 5 370mm Height 14 5 370mm Depth 3 75 95mm Weight 12 1 lbs 5 5 Kg including bracket Connectorized Specification Dimensions Width 12 305mm Height 12 305mm Depth 4 01 105mm Weight 9 1 lbs 4 3 Kg including bracket Table 4 4 PTP 600 power supply specifications Power Supply Separate power supply unit included Dimensions ...

Страница 155: ...with G 823 G 824 Surge Protection and Power Cross Compliant with GR1089 EN60950 Table 4 6 PTP 600 PTP SYNC physical specifications PTP SYNC Specification Dimensions Width excluding ears 6 69in 174mm Width including ears 7 54in 196mm Height 1 21in 31 5mm Depth 3 04in 79mm Weight 485 gm Power supply Integrated with PIDU Power source 39 V dc to 60 V dc Power consumption 1 5 W max Safety compliance Ta...

Страница 156: ...PTP 600 general reference information Chapter 4 Reference information phn 0896_009v003 4 8 UNDER DEVELOPMENT Feb 2010 International CB certified certificate to IEC 60950 ...

Страница 157: ...an EMC immunity compliance Complies with European EMC Specification EN301 489 1 with testing carried out to the detailed requirements of EN301 489 4 NOTE For EN 61000 4 2 1995 Electro Static Discharge ESD Class 2 8 kV air 4 kV contact discharge the PTP 600 has been tested to ensure immunity to 15kV air and 8kV contact ...

Страница 158: ... policies guidelines and requirements in Part 1 of Title 47 of the Code of Federal Regulations as well as the guidelines and suggestions for evaluating compliance in FCC OET Bulletin 65 Health Canada limits for the general population See the Health Canada web site at http www hc sc gc ca ewh semt pubs radiation 99ehd dhm237 limits limites_e html and Safety Code 6 EN 50383 2002 Basic standard for t...

Страница 159: ...energy in the 2 4 5 2 5 4 5 8 and 5 9 GHz frequency bands Calculation of power density NOTE The following calculation is based on the ANSI IEEE C95 1 1991 method as that provides a worst case analysis Details of the assessment to EN50383 2002 can be provided if required Peak power density in the far field of a radio frequency point source is calculated as follows Where Is S power density in W m2 P...

Страница 160: ...ally accepted limits for the general population Table 4 8 Power compliance margins Equation Variables Band Antenna Max Average Transmit Power in Burst Watt P Watt G factor S W m2 d m Recommended Distance m Compliance Margin 2 5 GHz Integrated 0 25 0 2 63 10 0 32 2 6 0 4 5 GHz Integrated 0 5 0 4 158 10 0 71 5 7 0 Integrated 0 5 0 4 158 10 0 71 5 7 0 4 8 GHz Connectorized 0 5 0 4 398 10 1 1 5 4 5 In...

Страница 161: ...egulations require that the power used for the calculations is the maximum power in the transmit burst subject to allowance for source based time averaging At 5 4 GHz and EU 5 8 GHz the products are generally limited to a fixed EIRP which can be achieved with the Integrated Antenna The calculations above assume that the maximum EIRP allowed by the regulations is being transmitted NOTE If there are...

Страница 162: ...PTP 600 general reference information Chapter 4 Reference information phn 0896_009v003 4 14 UNDER DEVELOPMENT Feb 2010 ...

Страница 163: ...ion Temperature ODU 40 F 40 C to 140 F 60 C PIDU Plus indoor deployment 32 F 0 C to 104o F 40 C PIDU Plus outdoor deployment within weatherproofed cabinet 40 F 40 C to 140 F 60 C PTP SYNC 40 F 40 C to 140 F 60 C Wind Loading 150mph Max 242kph See Wind loading on page 2 7 for a full description Humidity 100 Condensing ODU only Waterproof IP65 ODU only UV Exposure 10 year operational life UL746C tes...

Страница 164: ...4 10 shows how the regulatory limits currently apply in specific countries Operators should note that regulations are subject to change Table 4 10 PTP 25600 examples of regulatory limits Region Examples of Regulatory Limits at 2 5 GHz FCC Under FCC Regulations operation of this product is only allowed with a License Key for Region 16 which ensures that the product will meet the requirements of FCC...

Страница 165: ...16 the EIRP limit is approximately 63 dBm 10 x Log 360 Antenna Azimuth BW PTP25600 products are not able to exceed this EIRP limit with any available antenna The 30MHz bandwidth is not approved in FCC regions Table 4 11 PTP 25600 licenses and region codes Region Code License Regulation Frequencies DFS Channel Bandwidth Max Power FCC Upper 2624 2690 MHz 5 10 15 30 MHz 63 dBm EIRP FCC Middle 2572 26...

Страница 166: ...uency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to correct the interference by one or more of the following measures Increase the separation betwe...

Страница 167: ...ction Dynamic Frequency Control N A Channel size 5 10 15 and 30 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 5 dB Antenna Type Integrated flat plate antenna Antenna Gain 18 dBi typical Antenna Beamwidth 18 Degrees Max Path Loss 5 MHz channel 157 dB Duplex ...

Страница 168: ...dulation Threshold changes Error Correction FEC PTP 25600 emissions and radio certifications Table 4 13 lists the EMC emissions specifications under which the PTP 25600 has received type approval Table 4 14 lists the radio specifications under which the PTP 25600 has received type approval Table 4 13 PTP 25600 EMC emissions compliance Region Specification Type Approvals USA FCC Part 15 Class B Tab...

Страница 169: ...d region code 16 Lower 2496 MHz to 2572 MHz with a 5 5MHz channel raster 76 MHz total Middle 2572 MHz to 2614 MHz with a 6 MHz channel raster 42 MHz total Upper 2618 MHz to 2690 MHz with a 5 5 MHz channel raster 76 MHz total NOTE For the PTP 25600 product variant the unit will only operate in Fixed Frequency mode and the user is unable to select i DFS The PTP 25600 product variant support channel ...

Страница 170: ...2532 25 2537 75 2543 25 2548 75 2554 25 2559 75 Lower Band Segment 30 2513 2524 2535 2546 5 2575 2581 2587 2593 2599 2605 2611 10 2578 2584 2590 2596 2602 2608 15 2581 2587 2593 2599 2605 Middle Band Segment 30 2587 2599 5 2626 75 2632 25 2637 75 2643 25 2648 75 2654 25 2659 75 2665 25 2670 75 2676 25 2681 75 2687 25 10 2629 5 2635 2640 5 2646 2651 5 2657 2662 5 2668 2673 5 2679 2684 5 15 2632 25 ...

Страница 171: ...the BRS spectrum allocation These are configurable at installation and constrain the wireless to operate in a limited portion of the Spectrum The three frequency bands are as shown in Figure 4 1 Band 1 channels A B C and D 16 5 MHz blocks Band 2 channels A through G 6 MHz blocks Band 3 channels E F G and H 16 5 MHz blocks Figure 4 1 PTP 25600 BRS band channel assignments ...

Страница 172: ...56 6 154 1 152 0 149 4 QPSK 0 63 single 93 9 90 7 90 5 86 7 23 152 9 149 7 146 6 145 7 QPSK 0 87 single 90 7 87 6 87 5 83 9 23 149 7 146 6 146 5 142 9 16QAM 0 63 single 89 1 86 0 86 0 82 1 23 148 0 145 5 145 0 140 4 16QAM 0 63 dual 86 7 83 9 84 0 79 4 23 145 7 142 9 143 0 138 4 16QAM 0 87 single 84 2 82 5 80 5 76 5 23 143 2 141 4 139 5 135 5 16QAM 0 87 dual 81 0 77 7 77 4 72 9 23 140 0 136 6 136 4...

Страница 173: ... 85 1 81 5 23 147 3 144 6 144 1 140 5 16QAM 0 63 single 86 4 83 9 83 5 79 4 23 145 4 142 9 142 5 138 4 16QAM 0 63 dual 84 2 80 8 80 7 76 6 23 143 2 139 8 139 7 135 6 16QAM 0 87 single 81 7 78 1 77 3 73 6 23 140 7 137 1 136 3 132 6 16QAM 0 87 dual 78 6 74 4 74 3 70 0 23 137 6 133 4 133 3 129 0 64QAM 0 75 single 78 8 75 2 74 2 70 6 23 137 8 134 2 133 2 129 6 64QAM 0 75 dual 75 4 71 0 70 9 66 7 23 13...

Страница 174: ...latory limits Region Examples of Regulatory Limits at 4 5 GHz US Federal Operation of this product is only allowed with a License Key for Region 23 US Federal NTIA Operation of this product is only allowed with a License Key for Region 24 PTP 45600 licenses and region codes PTP 45600 units may be operated in any of the regions listed in Table 4 19 When shipped PTP 45600 units are configured with a...

Страница 175: ...n automatic selection on start up and continual adaptation to avoid interference Channel size 5 10 15 20 and 30 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 5 dB Antenna Type Integrated flat plate antenna Antenna Gain 21 5 dBi typical Antenna Beamwidth 11 ...

Страница 176: ...ive Modulation Threshold changes Error Correction FEC PTP 45600 emissions and radio certifications Table 4 21 lists the EMC emissions specifications under which the PTP 45600 has received type approval Table 4 22 lists the radio specifications under which the PTP 45600 has received type approval Table 4 21 PTP 45600 EMC emissions compliance Region Specification Type Approvals US Federal Table 4 22...

Страница 177: ...of the lower centre frequency allows the operator to slide the available frequency settings up and down the 4 5 GHz band in steps of 2 MHz In the 30 MHz Figure 4 2 and 20 MHz Figure 4 3 channel bandwidths the PTP 45600 variant operates on a 10 MHz channel raster In the 15 MHz Figure 4 4 10 MHz Figure 4 5 and 5 MHz Figure 4 6 channel bandwidths the PTP 45600 variant operates on a 6 MHz channel rast...

Страница 178: ...on Chapter 4 Reference information phn 0896_009v003 4 30 UNDER DEVELOPMENT Feb 2010 Figure 4 3 PTP 45600 available spectrum in 20 MHz channel bandwidth RC 23 Figure 4 4 PTP 45600 available spectrum in 15 MHz channel bandwidth RC 23 ...

Страница 179: ...l bandwidth RC 23 Figure 4 6 PTP 45600 available spectrum in 5 MHz channel bandwidth RC 23 Region code 24 NTIA In the 20 MHz Figure 4 7 channel bandwidth the PTP 45600 variant operates on a 20 MHz channel raster In the 10 MHz Figure 4 8 channel bandwidth the PTP 45600 variant operates on a 10 MHz channel raster The channel raster is set to even centre frequencies ...

Страница 180: ...on Chapter 4 Reference information phn 0896_009v003 4 32 UNDER DEVELOPMENT Feb 2010 Figure 4 7 PTP 45600 available spectrum in 20 MHz channel bandwidth RC 24 Figure 4 8 PTP 45600 available spectrum in 10 MHz channel bandwidth RC 24 ...

Страница 181: ...160 4 158 0 QPSK 0 63 single 92 0 91 4 89 3 88 5 85 8 27 160 5 159 9 159 3 158 5 155 8 QPSK 0 87 single 90 0 87 6 85 7 84 9 82 2 27 160 0 157 6 155 7 154 9 152 2 16QAM 0 63 single 88 3 85 5 83 3 82 5 80 1 27 158 3 155 5 153 3 152 5 150 1 16QAM 0 63 dual 85 5 81 9 79 5 78 9 77 1 27 155 5 151 9 149 5 148 9 147 1 16QAM 0 87 single 84 6 80 7 78 6 77 8 75 5 27 154 6 150 7 148 6 147 8 145 5 16QAM 0 87 d...

Страница 182: ... 87 single 88 1 85 4 83 3 81 6 79 5 27 160 3 159 1 157 8 156 0 153 1 16QAM 0 63 single 86 1 82 8 80 7 79 2 77 2 27 156 1 152 8 150 7 149 2 147 2 16QAM 0 63 dual 82 5 79 1 77 2 75 6 73 9 27 152 5 149 1 147 2 145 6 143 9 16QAM 0 87 single 81 2 78 2 76 1 74 4 72 0 27 151 2 148 2 146 1 144 4 142 0 16QAM 0 87 dual 77 7 74 4 72 4 70 8 69 2 27 147 7 144 4 142 4 140 8 139 2 64QAM 0 75 single 77 7 74 5 72 ...

Страница 183: ... regulatory limits Table 4 25 shows how the regulatory limits currently apply in specific countries Operators should note that regulations are subject to change Table 4 25 PTP 48600 examples of regulatory limits Region Examples of Regulatory Limits at 5 4GHz US Federal Operation of this product is only allowed with a License Key for Regions 15 or 23 US Federal NTIA Operation of this product is onl...

Страница 184: ... is to be installed in any other permitted region the user must obtain a new license key from the reseller or distributor Table 4 26 PTP 48600 licenses and region codes Region Code License Regulation Frequencies DFS Channel Bandwidth Max Power 14 USA Canada Public Safety 4940 4990 MHz 5 10 20 MHz 24 dBm 15 US Federal Extended 4710 5000 MHz 5 10 15 20 MHz 27 dBm 23 US Federal 4710 4940 MHz 5 10 15 ...

Страница 185: ...tion automatic selection on start up and continual adaptation to avoid interference Channel size 5 10 15 and 20 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 5 dB Antenna Type Integrated flat plate antenna Antenna Gain 22 dBi typical Antenna Beamwidth 11 De...

Страница 186: ...ive Modulation Threshold changes Error Correction FEC PTP 48600 emissions and radio certifications Table 4 28 lists the EMC emissions specifications under which the PTP 48600 has received type approval Table 4 29 lists the radio specifications under which the PTP 48600 has received type approval Table 4 28 PTP 48600 EMC emissions compliance Region Specification type approvals US Federal Table 4 29...

Страница 187: ...cy allows the operator to slide the available frequency settings up and down the 4 8 GHz band in steps of 1 MHz In the 20 MHz Figure 4 9 channel bandwidth the PTP 48600 variant operates on a 10 MHz channel raster In the 15 MHz Figure 4 10 10 MHz Figure 4 11 and 5 MHz Figure 4 12 channel bandwidths the PTP 48600 variant operates on a 5 MHz channel raster The channel raster is set to even centre fre...

Страница 188: ... 4 Reference information phn 0896_009v003 4 40 UNDER DEVELOPMENT Feb 2010 Figure 4 10 PTP 48600 available spectrum in 15 MHz channel bandwidth RC 15 and 23 Figure 4 11 PTP 48600 available spectrum in the 10 MHz channel bandwidth RC 15 and 23 ...

Страница 189: ...dth RC 15 and 23 Region code 24 NTIA In the 20 MHz Figure 4 13 channel bandwidth the PTP 48600 variant operates on a 20 MHz channel raster In the 10 MHz Figure 4 14 channel bandwidth the PTP 48600 variant operates on a 10 MHz channel raster The channel raster is set to even centre frequencies Figure 4 13 PTP 48600 available spectrum in the 20 MHz channel bandwidth RC 24 ...

Страница 190: ...PTP 48600 reference information Chapter 4 Reference information phn 0896_009v003 4 42 UNDER DEVELOPMENT Feb 2010 Figure 4 14 PTP 48600 available spectrum in 10 MHz channel bandwidth RC 24 ...

Страница 191: ... 9 QPSK 0 63 single 94 3 90 7 89 6 87 5 27 27 165 3 161 7 160 6 158 5 QPSK 0 87 single 90 8 87 3 85 9 84 0 27 26 161 8 158 3 156 9 154 0 16QAM 0 63 single 88 7 85 2 83 6 81 8 25 25 157 7 154 2 152 6 150 8 16QAM 0 63 dual 85 3 81 6 80 0 78 5 25 25 154 3 150 6 149 0 147 5 16QAM 0 87 single 84 4 80 6 78 8 77 3 25 25 153 4 149 6 147 8 146 3 16QAM 0 87 dual 81 0 77 2 75 9 74 5 25 25 150 0 146 2 144 9 1...

Страница 192: ... 2 83 5 81 9 27 26 158 9 156 2 154 5 151 9 16QAM 0 63 single 85 4 82 7 81 1 79 6 25 25 154 4 151 7 150 1 148 6 16QAM 0 63 dual 81 9 79 5 77 8 76 5 25 25 150 9 148 5 146 8 145 5 16QAM 0 87 single 81 0 78 2 76 8 75 5 25 25 150 0 147 2 145 8 144 5 16QAM 0 87 dual 77 8 75 4 74 0 72 5 25 25 146 8 144 4 143 0 141 5 64QAM 0 75 single 77 9 75 2 73 9 72 6 23 23 144 9 142 2 140 9 139 6 64QAM 0 75 dual 75 0 ...

Страница 193: ... Kong Public Safety Operation of this product is only allowed with a License Key for Region 14 USA Canada Public Safety or Region 18 Hong Kong Public Safety PTP 49600 licenses and region codes PTP 49600 units may be operated in any of the regions listed in Table 4 33 When shipped PTP 49600 units are configured with a license key for region code 14 An alternative license key is provided in the PTP ...

Страница 194: ...regulatory compliance The PTP 49600 complies with the regulations that are in force in the USA and Canada The relevant notifications are specified in this section PTP 49600 FCC and IC notification The system has been approved under FCC Part 90 and Industry Canada RSS 111 for Public Safety Agency usage The installer or operator is responsible for obtaining the appropriate site licenses before insta...

Страница 195: ...tic selection on start up and continual adaptation to avoid interference Channel size 5 10 and 20 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 5 dB Antenna Type Integrated flat plate antenna Antenna Gain Typical 22 dBi Maximum permitted 26 dBi Antenna Beam...

Страница 196: ...hanges Error Correction FEC PTP 49600 emissions and radio certifications Table 4 35 lists the EMC emissions specifications under which the PTP 49600 has received type approval Table 4 36 lists the radio specifications under which the PTP 49600 has received type approval Table 4 35 PTP 49600 EMC emissions compliance Region Specification Type Approvals USA FCC Part 15B Table 4 36 PTP 49600 radio cer...

Страница 197: ... 17 channel bandwidths the PTP 49600 variant operates on a 5 MHz channel raster The channel raster is set to even centre frequencies NOTE These tables contain data for one typical region code The specified channel centre frequencies may not be available in other region codes The PTP 49600 product variant does not apply any band edge power reduction Figure 4 15 PTP 49600 available spectrum in 20 MH...

Страница 198: ...PTP 49600 reference information Chapter 4 Reference information phn 0896_009v003 4 50 UNDER DEVELOPMENT Feb 2010 Figure 4 17 PTP 49600 available spectrum in the 5 MHz channel bandwidth ...

Страница 199: ... 10 MHz 20 MHz BPSK 0 63 single 98 6 95 5 91 9 24 166 6 163 5 159 9 QPSK 0 63 single 94 3 90 7 87 5 24 162 3 158 7 155 5 QPSK 0 87 single 90 8 87 3 84 0 24 158 8 155 3 152 0 16QAM 0 63 single 88 7 85 2 81 8 24 156 7 153 2 149 8 16QAM 0 63 dual 85 3 81 6 78 5 24 153 3 149 6 146 5 16QAM 0 87 single 84 4 80 6 77 3 24 152 4 148 6 145 3 16QAM 0 87 dual 81 0 77 2 74 5 24 149 0 145 2 142 5 64QAM 0 75 sin...

Страница 200: ... 85 7 24 159 4 156 8 153 7 QPSK 0 87 single 87 9 85 2 81 9 24 155 9 153 2 149 9 16QAM 0 63 single 85 4 82 7 79 6 24 153 4 150 7 147 6 16QAM 0 63 dual 81 9 79 5 76 5 24 149 9 147 5 144 5 16QAM 0 87 single 81 0 78 2 75 5 24 149 0 146 2 143 5 16QAM 0 87 dual 77 8 75 4 72 5 24 145 8 143 4 140 5 64QAM 0 75 single 77 9 75 2 72 6 23 144 9 142 2 139 6 64QAM 0 75 dual 75 0 72 6 69 3 23 142 0 139 6 136 3 64...

Страница 201: ...BW and 30 dBm ETSI Operation of this product is only allowed with a License Key for Region 26 This implements Radar Detection including barring of the band from 5600 MHz to 5650 MHz and limits the EIRP to the regulatory limits below EIRP Max of 17 10 x Log Channel BW and 30 dBm Australia Canada Operation of this product is only allowed with a License Key for Region 13 This implements Radar Detecti...

Страница 202: ...ense key for region code 26 Alternative license keys are provided in the PTP 600 Installation Guide for region codes 12 and 13 If the link is to be installed in any other permitted region the user must obtain a new license key from the reseller or distributor Table 4 40 PTP 54600 licenses and region codes Region code License Regulation Frequencies DFS Channel Bandwidth Max Power Notes 7 Full Power...

Страница 203: ...IRP 15 MHz 28 dBm EIRP 10 MHz 27 dBm EIRP 21 Korea 5470 5650 MHz 5 MHz 24 dBm EIRP 30 MHz 30 dBm EIRP 15 MHz 27 dBm EIRP 10 MHz 25 dBm EIRP 26 ETSI 5470 5600 MHz 5650 5725 MHz Yes 5 MHz 22 dBm EIRP The band 5600 MHz to 5650 MHz is reserved for the use of weather radars PTP 54600 regulatory compliance The PTP 54600 complies with the regulations that are in force in the USA Canada and Europe The rel...

Страница 204: ...ts for a Class B digital device pursuant to Part 15 of the US FCC Rules and with RSS 210 of Industry Canada These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to rad...

Страница 205: ... requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at http motorola canopywireless com doc php This equipment is marked to show compliance with the European R TTE directive 1999 5 EC European Union EU Waste of Electrical and Electronic Equipment WEEE directive The European Union s WEEE directive requires that products sold into EU coun...

Страница 206: ...ntrol Initial capture 10 15 sec Out of service on interference 100 ms Channel size 5 10 15 and 30 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 6 dB Integrated Antenna Type Gain Integrated flat plate antenna 23dBi External Antenna Gain Depends on feeder los...

Страница 207: ...ertifications Table 4 42 lists the EMC emissions specifications under which the PTP 54600 has received type approval Table 4 43 lists the radio specifications under which the PTP 54600 has received type approval Table 4 42 PTP 54600 EMC emissions compliance Region Specification Type Approvals USA FCC Part 15 Class B Canada CSA Std C108 8 1993 Class B Europe EN55022 CISPR 22 Table 4 43 PTP 54600 ra...

Страница 208: ...In the 30 MHz channel bandwidth Figure 4 18 the PTP 54600 variant operates on a 10 MHz channel raster In the 15 MHz Figure 4 19 10 MHz Figure 4 20 and 5 MHz Figure 4 21 channel bandwidths the PTP 54600 variant operates on a 6 MHz channel raster The channel raster is set to even centre frequencies The PTP 54600 product variant does not apply any band edge power reduction NOTE These tables contain d...

Страница 209: ...on phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 4 61 Figure 4 19 PTP 54600 available spectrum in 15 MHz channel bandwidth Figure 4 20 PTP 54600 available spectrum in 10 MHz channel bandwidth Figure 4 21 PTP 54600 available spectrum in 5 MHz channel bandwidth ...

Страница 210: ...6 92 3 88 9 25 169 2 165 6 163 3 159 9 QPSK 0 63 single 93 0 90 0 88 5 82 9 24 163 0 160 0 158 5 152 9 QPSK 0 87 single 90 2 86 7 85 3 80 1 23 159 2 155 7 154 3 149 1 16QAM 0 63 single 88 0 83 8 82 8 78 3 22 156 0 151 8 150 8 146 3 16QAM 0 63 dual 84 3 80 7 79 3 74 6 22 152 3 148 7 147 3 142 6 16QAM 0 87 single 82 4 79 1 78 2 73 0 20 148 4 145 1 144 2 139 0 16QAM 0 87 dual 79 7 75 7 74 7 70 6 20 1...

Страница 211: ...single 86 7 84 3 82 3 78 4 23 155 6 153 3 151 3 147 4 16QAM 0 63 single 86 6 81 8 79 9 76 0 22 151 7 149 8 147 9 144 0 16QAM 0 63 dual 83 7 78 2 76 5 72 4 22 148 8 146 3 144 5 140 4 16QAM 0 87 single 78 8 76 6 75 5 69 8 20 144 8 142 6 141 5 135 8 16QAM 0 87 dual 76 9 73 9 72 2 68 7 20 142 9 139 9 138 2 134 7 64QAM 0 75 single 74 7 72 2 71 8 66 6 18 138 7 136 2 135 8 130 6 64QAM 0 75 dual 73 0 70 4...

Страница 212: ...TP 600 Series and the antenna ports must not be less than 1 2 dB CAUTION Antennas not included in this table or those having a gain greater than the specified maximum are strictly prohibited for use with the PTP 54600 The required antenna impedance is 50 ohms Table 4 46 Allowed antennas for deployment in USA Canada 5 4 GHz Manufacturer Antenna Type Gain dBi Parabolic Dish Andrew Andrew 2 foot Para...

Страница 213: ...ndard QuickFire Parabolic QF4 52 N 34 8 Y Gabriel Gabriel 4 foot Standard QuickFire Parabolic QF4 52 N RK 34 8 Y Gabriel Gabriel 2 foot Standard Dual QuickFire Parabolic QFD2 52 N 28 4 Y Gabriel Gabriel 2 5 foot Standard Dual QuickFire Parabolic QFD2 5 52 N 31 1 Y Gabriel Gabriel 2 foot Standard Dual QuickFire Parabolic QFD2 52 N RK 28 4 Y Gabriel Gabriel 4 foot Standard Dual QuickFire Parabolic Q...

Страница 214: ...ves Radio Waves 2 foot Parabolic SP2 2 5 28 3dBi 28 3 Y RadioWaves Radio Waves 3 foot Parabolic SP3 2 5 31 4dBi 31 4 Y RadioWaves Radio Waves 4 foot Parabolic SP4 2 5 34 6dBi 34 6 Y RFS RFS 2 foot Parabolic SPF2 52AN or SPFX2 52AN 27 9dBi 27 9 Y RFS RFS 3 foot Parabolic SPF3 52AN or SPFX3 52AN 31 4dBi 31 4 Y RFS RFS 4 foot Parabolic SPF4 52AN or SPFX4 52AN 33 9dBi 33 9 Y RFS RFS 2 foot HP Paraboli...

Страница 215: ...on China Operation of this product is only allowed with a License Key for Region 2 33 dBm or 2W EIRP Australia Operation of this product is only allowed with a License Key for Region 3 36 dBm or 4W EIRP Hong Kong Operation of this product is only allowed with a License Key for Region 3 36 dBm or 4W EIRP UK Operation of this product is allowed with a License Key for Region 4 This implements Radar D...

Страница 216: ...s the EIRP to the Regulatory Limits below EIRP Max of 20 10 x Log Channel BW and 33 dBm Norway Under Norway Regulations operation of this product is only allowed with a License Key for Region 7 This implements Radar Detection and limits the EIRP to the Regulatory Limits below EIRP Max of 40 10 x Log Channel BW and 53 dBm Spectral density at border between Norway and neighboring countries shall not...

Страница 217: ...User Guide PTP 600 Series PTP 58600 reference information phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 4 69 ...

Страница 218: ...new license key from the reseller or distributor Table 4 48 PTP 58600 licenses and region codes Region code License Regulation Frequencies DFS Channel Bandwidth Max Power Notes 1 FCC USA Canada Taiwan Brazil 5725 5850 MHz 5 10 15 30 MHz 25 dBm Reduced TX power at band edges 30 MHz 33 dBm EIRP 15 MHz 31 dBm EIRP 10 MHz 30 dBm EIRP 2 China 5725 5850 MHz 5 MHz 27 dBm EIRP 3 Australia Hong Kong 5725 5...

Страница 219: ...dBm EIRP 10 MHz 30 dBm EIRP 6 Eire 5725 5850 MHz 5 MHz 27 dBm EIRP 30 MHz 53 dBm EIRP 15 MHz 51 dBm EIRP 10 MHz 50 dBm EIRP 7 Norway 5725 5795 MHz 5815 5850 MHz Yes 5 MHz 47 dBm EIRP 5795 MHz to 5815 MHz is assigned for Road Transport and Traffic Telematics RTTT 8 Full Power 5725 5850 MHz 5 10 15 30 MHz 25 dBm 30 MHz 43 dBm EIRP 15 MHz 41 dBm EIRP 10 MHz 40 dBm EIRP 11 Korea 5725 5825 MHz 5 MHz 37...

Страница 220: ...5 MHz 29 dBm EIRP 1dB reduction required in 30 MHz to achieve adjacent channel emissions 30 MHz 33 dBm EIRP 15 MHz 31 dBm EIRP 10 MHz 30 dBm EIRP 24 Bahrain 5725 5850 MHz Yes 5 MHz 27 dBm EIRP 30 MHz 35 dBm EIRP 15 MHz 34 dBm EIRP 10 MHz 32 dBm EIRP 25 ETSI 5725 5850 MHz Yes 5 MHz 29 dBm EIRP 1dB reduction required in 30 MHz to achieve adjacent channel emissions 30 MHz 35 dBm EIRP 15 MHz 34 dBm EI...

Страница 221: ... Guide PTP 600 Series PTP 58600 reference information phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 4 73 Region code License Regulation Frequencies DFS Channel Bandwidth Max Power Notes 5 MHz 29 dBm EIRP RTTT ...

Страница 222: ...ioned to take note that high power radars are allocated as primary users meaning they have priority of the 5650 5850 MHz spectrum and these radars could cause interference and or damage to license exempt local area networks LELAN For the connectorized version of the product and in order to reduce potential radio interference to other users the antenna type and its gain should be so chosen that the...

Страница 223: ...Class 2 device as it operates on frequencies that are not harmonized across the EU Currently the product may only be operated in the UK Eire IRL Germany Norway and Denmark However the regulatory situation in Europe is changing and the radio spectrum may become available in other countries in future See www ero dk for further information The operator is responsible for obtaining any national licens...

Страница 224: ...8600 connectorized product has been notified for operation in the UK and when operated in accordance with instructions for use it is compliant with UK Interface Requirement IR2007 For UK use installations must conform to the requirements of IR2007 in terms of EIRP spectral density against elevation profile above the local horizon in order to protect Fixed Satellite Services The frequency range 579...

Страница 225: ... to avoid interference Dynamic Frequency Control Initial capture 10 15 sec Out of service on interference 100 ms Channel size 5 10 15 and 30 MHz Manual Power Control Maximum power can be controlled lower than the power limits shown above in order to control interference to other users of the band Receiver Noise Figure Typically 6 dB Antenna Type Integrated Flat plate antenna 23 dBi Antenna Type Ex...

Страница 226: ...es may be reduced during high winds through trees due to Adaptive Modulation Threshold changes Error Correction FEC PTP 58600 emissions and radio certifications Table 4 50 lists the EMC emissions specifications under which the PTP 58600 has received type approval Table 4 51 lists the radio specifications under which the PTP 58600 has received type approval Table 4 50 PTP 58600 EMC emissions compli...

Страница 227: ...ce information phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 4 79 Table 4 51 PTP 58600 radio certifications Region Specification Type Approvals USA FCC Part 15 247 CANADA RSS 210 Issue 7 Annex 8 UK IR 2007 Eire ComReg 02 71R1 EU EN302 502 v 1 2 1 ...

Страница 228: ...wn the 5 8 GHz band in steps of 2 MHz In the 30 MHz channel bandwidth Figure 4 22 the PTP 58600 variant operates on a 10 MHz channel raster In the 15 MHz Figure 4 23 10 MHz Figure 4 24 and 5 MHz Figure 4 25 channel bandwidths the PTP 58600 variant operates on a 6 MHz channel raster The channel raster is set to even centre frequencies NOTE These tables contain data for one typical region code The s...

Страница 229: ... phn 0896_009v003 Feb 2010 UNDER DEVELOPMENT 4 81 Figure 4 23 PTP 58600 available spectrum in 15 MHz channel bandwidth Figure 4 24 PTP 58600 available spectrum in the 10 MHz channel bandwidth Figure 4 25 PTP 58600 available spectrum in 5 MHz channel bandwidth ...

Страница 230: ... region code of the region of operation This currently only affects systems configured with region code 1 The power reductions in the edge channels for 5 MHz 10 MHz 15 MHz and 30 MHz are presented in Table 4 52 for region code 1 ONLY Table 4 52 PTP 58600 band edge Tx power reduction Channel Width MHz Power Levels for Channel Centre 5 10 15 30 5730 25 N A N A N A 5732 25 23 N A N A 5734 25 25 N A N...

Страница 231: ...66 1 163 5 161 8 157 3 QPSK 0 63 single 91 9 90 0 87 7 83 0 24 161 9 160 0 157 7 153 0 QPSK 0 87 single 88 7 86 6 84 8 80 3 23 157 7 155 6 153 8 149 3 16QAM 0 63 single 86 0 84 3 82 4 78 3 22 154 0 152 3 150 4 146 3 16QAM 0 63 dual 83 5 80 4 78 5 75 3 22 151 5 148 4 146 5 143 3 16QAM 0 87 single 82 1 79 5 78 1 72 5 20 148 1 145 5 144 1 138 5 16QAM 0 87 dual 79 2 76 2 73 9 71 5 20 145 2 142 2 139 9...

Страница 232: ...87 single 85 5 83 8 81 6 77 8 23 154 5 152 8 150 6 146 8 16QAM 0 63 single 82 0 81 3 79 1 75 3 22 150 0 149 3 147 1 143 3 16QAM 0 63 dual 79 4 77 6 75 6 71 7 22 147 4 145 6 143 6 139 7 16QAM 0 87 single 78 7 76 3 74 7 71 2 20 144 7 142 3 140 7 137 2 16QAM 0 87 dual 75 1 73 2 71 0 67 7 20 141 0 139 2 137 0 133 7 64QAM 0 75 single 74 4 72 3 70 6 67 9 18 138 4 136 3 134 6 131 9 64QAM 0 75 dual 70 9 6...

Страница 233: ...ports must not be less than 1 2 dB CAUTION Antennas not included in this table or those having a gain greater than the specified maximum are strictly prohibited for use with the PTP 58600 The required antenna impedance is 50 ohms Table 4 55 Allowed antennas for deployment in USA Canada 5 8 GHz Manufacturer Antenna Type Gain dBi Flat Plate Parabolic Dish Andrew Andrew 1 foot Flat Panel FPA5250D12 N...

Страница 234: ...Parabolic PX3F 52 33 4dBi 33 4 Y Andrew Andrew 4 foot Parabolic P4F 52 34 9dBi 34 9 Y Andrew Andrew 4 foot Dual Pol Parabolic PX4F 52 34 9dBi 34 9 Y Andrew Andrew 6 foot Parabolic P6F 52 37 6dBi 37 6 Y Andrew Andrew 6 foot Dual Pol Parabolic PX6F 52 37 6dBi 37 6 Y Gabriel Gabriel 2 foot High Performance QuickFire Parabolic HQF2 52 N 28 2 Y Gabriel Gabriel 4 foot High Performance QuickFire Paraboli...

Страница 235: ...re Parabolic QF4 52 N RK 34 8 Y Gabriel Gabriel 6 foot Standard QuickFire Parabolic QF6 52 N 37 7 Y Gabriel Gabriel 2 foot Standard Dual QuickFire Parabolic QFD2 52 N 28 4 Y Gabriel Gabriel 2 5 foot Standard Dual QuickFire Parabolic QFD2 5 52 N 31 1 Y Gabriel Gabriel 2 foot Standard Dual QuickFire Parabolic QFD2 52 N RK 28 4 Y Gabriel Gabriel 4 foot Standard Dual QuickFire Parabolic QFD4 52 N 34 7...

Страница 236: ... 37 5 Y RadioWaves Radio Waves 6 foot Parabolic SP6 5 2 37 7dBi 37 7 Y RadioWaves Radio Waves 2 foot Parabolic SP2 2 5 28 3dBi 28 3 Y RadioWaves Radio Waves 3 foot Parabolic SP3 2 5 31 4dBi 31 4 Y RadioWaves Radio Waves 4 foot Parabolic SP4 2 5 34 6dBi 34 6 Y RadioWaves Radio Waves 6 foot Parabolic SP6 2 5 37 7dBi 37 7 Y RFS RFS 2 foot Parabolic SPF2 52AN or SPFX2 52AN 27 9dBi 27 9 Y RFS RFS 3 foo...

Страница 237: ...h RFS RFS 6 foot HP Parabolic SDF6 52AN or SDFX6 52AN 37 4dBi 37 4 Y StellaDoradus StellaDoradus 45 inch Parabolic Antenna 58PSD113 33 8 Y Table 4 56 Sectored antennas for deployment in USA Canada 5 8 GHz Manufacturer Antenna Type Gain dBi Beamwidth RadioWaves SEC 55V 60 17 SEC 55H 60 17 SEC 55D 60 17 17 60 RadioWaves SEC 55V 90 16 SEC 55H 90 16 SEC 55D 90 16 16 90 ...

Отзывы: