Motorola Solutions AP-7131N-FGR Access Point Product Reference Guide
9-18
list can be re-populated with more desirable device MAC addresses from the Available Base
Bridge List.
14. Click
Ok
to return to the Radio Configuration screen. Within the Radio Configuration screen,
click
Apply
to save any changes made within the Advanced Client Bridge Settings screen.
15. Click
Cancel
to undo any changes made within the Advanced Client Bridge Settings screen.
This reverts all settings for the screen to the last saved configuration.
16. If using a dual-radio model access point, refer to the
Mesh Timeout
drop-down menu (from
within the Radio Configuration screen) to define whether one of the access point’s radio’s
beacons on an existing WLAN or if a client bridge radio uses an uplink connection. The Mesh
Timeout value is not available on a single-radio access point, since the radio would have to
stop beaconing and go into scan mode to determine if a base bridge uplink is lost. The
following drop-down menu options are available:
Disabled
When disabled, both radios are up at boot time and beaconing. If
one radio (radio 1) does not have a mesh connection, the other
radio (radio 2) is not affected. Radio 2 continues to beacon and
associate MUs, but MU's can only communicate amongst
themselves using the access point. Disabled is the default value.
Uplink Detect
When Uplink Detect is selected, the access point only boots up the
radio configured as a client bridge. The access point boots up the
second radio as soon as the first mesh connection is established.
However, if the client bridge radio loses its uplink connection, the
second radio shuts down immediately.
Enabled
If the mesh connection is down on one radio (radio 1), the other
radio (radio 2) is brought down and stops beaconing after the
timeout period (45 seconds). This allows the client bridge (radio 1)
to roam without dropping the MU's associated to radio 2. The
disadvantage is that radio 2 may beacon for the 45 second timeout
period and have to drop associated MU's because radio 1 could not
establish its uplink.
NOTE
The Mesh Time Out variable overrides the
Ethernet Port Time Out
(EPTO)
setting on the LAN page when the access point is in bridge mode. As long
as the mesh is down, the access point acts in accordance to the Mesh
Time Out setting regardless of the state of the Ethernet. However, if the
Ethernet goes down and the mesh link is still up, the EPTO takes effect.
Содержание P-7131N-FGR
Страница 1: ...Motorola Solutions AP 7131N FGR Product Reference Guide M ...
Страница 3: ...AP 7131N FGR Access Point Product Reference Guide ...
Страница 4: ......
Страница 14: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 10 ...
Страница 46: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 1 30 ...
Страница 57: ...Hardware Installation 2 11 ...
Страница 70: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 2 24 ...
Страница 90: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 3 20 ...
Страница 224: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 5 78 ...
Страница 296: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide 6 72 ...
Страница 639: ...Configuring Mesh Networking 9 23 4 Enable base bridge functionality on the 802 11a n radio Radio 2 ...
Страница 692: ...Motorola Solutions AP 7131N FGR Access Point Product Reference Guide B 10 ...
Страница 699: ......