MINILINE 1000
MLK Amplifier Installation Sheet
Configuration
The shipped configuration of the MLK is noted on a label on top of the amplifier. Figure 2
illustrates the configuration notation:
Figure 2
Configuration notation
Key
L
M
Powering
Line powering
Mains powering
Key
0
X
2
4
6
8
10
12
dB Value Output Slope
Jumper
None
2 dB
4 dB
6 dB
8 dB
10 dB
12 dB
Key
8
Bandwidth
870 MHz
Key
32
38
Gain
32 dB
38 dB
Key
X
B
Supply Options
None
Battery back-up
Key
X
Reserved
Reserved
Key
K
F
M
C
I
Input/Output Connectors
KS conn, 5/8-24
F conn
KS input and F output conn
IEC input and F output conn
IEC type
MLK
8
G
X
X
X
Key
G
Technology
Key
A
K
E
S
Frequency Range
5-65 MHz, 85-870 MHz
5-42 MHz, 54-870 MHz
5-30 MHz, 47-870 MHz
5-40 MHz, 52-870 MHz
Key
S
H
Output level
Standard output
High output
Before You Begin
Before you install the MLK, verify that the following conditions are met:
!
The MLK operating voltage must conform to the local utility voltage.
!
Grounding is according to the national standard
!
Protection is class II
!
Use only the supplied power cable (mains ac power)
!
Use fuses with the rating indicated on the power supply cover
!
Use the MLK within its ambient temperature rating (
−
20
°
C to
+
55
°
C)